SELUTION 4 De Novo Small Vessel IDE Trial

NCT05946629 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 960

Last updated 2025-09-29

No results posted yet for this study

Summary

Prospective, randomized controlled, single-blind, multicenter, clinical trial to demonstrate the safety and efficacy of the SELUTION SLR 014 PTCA DEB for treatment of de novo lesions in small coronary vessels, defined as reference vessel diameter (RVD) of 2.00 mm to 2.75 mm, in support of a pre-market approval (PMA) application to the United States (US) FDA.

The Study will enroll up to 910 randomized subjects, up to 30 subjects in a parallel angiographic substudy, and up to 20 subjects in a parallel pharmacokinetic (pK) substudy, at up to 80 sites in the US, Canada, Brazil, Japan and Europe. A minimum of 50% of the subjects will be enrolled in the US.

Conditions

Interventions

DEVICE

PCI with SELUTION SLR DCB

After target lesion pre-dilatation and preparation , a SELUTION SLR 014 PTCA DEB study device should be selected with nominal diameter equal to the RVD of the target lesion (1:1 ratio) and length that allows approximately 2.00 mm longer than the proximal and distal edges of the target lesion (defined as the proximal and distal extent of predilation). If IVUS is performed to assess RVD, and DEB upsizing is deemed clinically necessary for optimal results, a maximum nominal DEB diameter of 3.0 mm is permitted. The SELUTION SLR 014 PTCA DEB should then be delivered, positioned in and deployed per instructions per use. The balloon should be inflated for 60 seconds provided that the patient can tolerate this duration. The minimum inflation time is 30 seconds.

DEVICE

PCI with FDA approved "-limus" DES

For subjects randomized to the control group (DES), the treating physician will choose an FDA cleared DES and follow lesion preparation and stent deployment according to the Instructions per use (IFU) and institutional practices. The DES should be sized per IFU with respect to the vessel RVD. The use of IVUS or OCT is encouraged to guide optimal stent placement and assess final results. After DES deployment, additional balloon inflations should be performed as needed to obtain \< 30% residual diameter stenosis and resolve proximal or distal edge dissections greater than or equal to NHLBI grade B.

Sponsors & Collaborators

  • NAMSA

    collaborator OTHER
  • Cordis Corporation

    collaborator INDUSTRY
  • M.A. Med Alliance S.A.

    lead INDUSTRY

Principal Investigators

  • Ron Waksman, MD · Medstar Health Research Institute

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2023-10-20
Primary Completion
2027-06-30
Completion
2031-06-30
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05946629 on ClinicalTrials.gov