Trial Outcomes & Findings for SpO2 Data Collection in Pediatric Patients Using INVSENSOR00061 (NCT NCT05896267)
NCT ID: NCT05896267
Last Updated: 2025-11-12
Results Overview
SpO2 accuracy will be determined by calculating the Arithmetic Root Mean Square (ARMs) value which will be reported as percent of oxygen saturated hemoglobin. The noninvasive oxygen saturation measurement (SpO2) from the INVSENSOR00061 will be compared to the noninvasive oxygen saturation measurement (SpO2) value from the RD SET Neo sensor.
COMPLETED
NA
64 participants
Approximately 15 minutes
2025-11-12
Participant Flow
Participant milestones
| Measure |
Masimo INVSENSOR00061
Experimental: INVSENSOR00061 All subjects are enrolled into this arm will have noninvasive blood oxygen measurements obtained.
Masimo INVSENSOR00061: Masimo INVSENSOR00061 will be used to measure noninvasive SpO2 (Oxygen Saturation )
|
|---|---|
|
Overall Study
STARTED
|
64
|
|
Overall Study
COMPLETED
|
60
|
|
Overall Study
NOT COMPLETED
|
4
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
SpO2 Data Collection in Pediatric Patients Using INVSENSOR00061
Baseline characteristics by cohort
| Measure |
Masimo INVSENSOR00061
n=60 Participants
Experimental: INVSENSOR00061 All subjects are enrolled into this arm will have noninvasive blood oxygen measurements obtained.
Masimo INVSENSOR00061: Masimo INVSENSOR00061 will be used to measure noninvasive SpO2 (Oxygen Saturation )
|
|---|---|
|
Age, Categorical
>=65 years
|
0 Participants
n=171 Participants
|
|
Age, Categorical
<=18 years
|
60 Participants
n=171 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
0 Participants
n=171 Participants
|
|
Sex: Female, Male
Female
|
25 Participants
n=171 Participants
|
|
Sex: Female, Male
Male
|
35 Participants
n=171 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
32 Participants
n=171 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
27 Participants
n=171 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
1 Participants
n=171 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=171 Participants
|
|
Race (NIH/OMB)
Asian
|
3 Participants
n=171 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
2 Participants
n=171 Participants
|
|
Race (NIH/OMB)
Black or African American
|
14 Participants
n=171 Participants
|
|
Race (NIH/OMB)
White
|
38 Participants
n=171 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=171 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
3 Participants
n=171 Participants
|
|
Region of Enrollment
United States
|
60 participants
n=171 Participants
|
PRIMARY outcome
Timeframe: Approximately 15 minutesPopulation: 30 subjects were excluded from the analysis and replaced with new participants because of incorrect sensor placement.
SpO2 accuracy will be determined by calculating the Arithmetic Root Mean Square (ARMs) value which will be reported as percent of oxygen saturated hemoglobin. The noninvasive oxygen saturation measurement (SpO2) from the INVSENSOR00061 will be compared to the noninvasive oxygen saturation measurement (SpO2) value from the RD SET Neo sensor.
Outcome measures
| Measure |
Masimo INVSENSOR00061
n=30 Participants
Experimental: INVSENSOR00061 All subjects are enrolled into this arm will have noninvasive blood oxygen measurements obtained.
Masimo INVSENSOR00061: Masimo INVSENSOR00061 will be used to measure noninvasive SpO2 (Oxygen Saturation ) in blood .
|
|---|---|
|
SpO2 Accuracy of INVSENSOR00061
|
0.87 percent of oxygen saturated hemoglobin
|
PRIMARY outcome
Timeframe: Approximately 15 minutesPopulation: 30 subjects were excluded from the analysis and replaced with new participants because of incorrect sensor placement.
Pulse Rate accuracy will be determined by calculating the Arithmetic Root Mean Square (ARMs) value through the comparison of the noninvasive Pulse Rate to the noninvasive Pulse Rate (PR) value obtained from the RD SET Neo sensor which will be reported as beats per minute.
Outcome measures
| Measure |
Masimo INVSENSOR00061
n=30 Participants
Experimental: INVSENSOR00061 All subjects are enrolled into this arm will have noninvasive blood oxygen measurements obtained.
Masimo INVSENSOR00061: Masimo INVSENSOR00061 will be used to measure noninvasive SpO2 (Oxygen Saturation ) in blood .
|
|---|---|
|
Pulse Rate Accuracy of INVSENSOR00061
|
4.45 beats per minute
|
Adverse Events
Masimo INVSENSOR00061
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: GT60