Trial Outcomes & Findings for A Study to Evaluate SimPull for Lateral Patient Transfer (NCT NCT05856123)
NCT ID: NCT05856123
Last Updated: 2025-10-22
Results Overview
The average total time (minutes) it took to complete a lateral transfer.
COMPLETED
NA
100 participants
Baseline
2025-10-22
Participant Flow
Only Group 1 and Group 2 were actual participants who were enrolled in the study. Data was only collected for Group 1 and Group 2. Group 3 consisted of clinicians (provided the intervention or standard of care to Group 1 and Group 2 participants). Group 3 did not receive any intervention nor were they enrolled in the study. Group 3 only participated in the post intervention/standard of care survey.
Participant milestones
| Measure |
Group 1: Standard of Care Transfer
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
Group 3: Clinicians
Study clinicians complete a survey after conducting intervention or standard of care on participants.
|
|---|---|---|---|
|
Overall Study
STARTED
|
50
|
50
|
7
|
|
Overall Study
COMPLETED
|
50
|
50
|
7
|
|
Overall Study
NOT COMPLETED
|
0
|
0
|
0
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Race and Ethnicity were not collected from any participant.
Baseline characteristics by cohort
| Measure |
Group 1: Standard of Care Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
Total
n=100 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=50 Participants
|
0 Participants
n=50 Participants
|
0 Participants
n=100 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
33 Participants
n=50 Participants
|
34 Participants
n=50 Participants
|
67 Participants
n=100 Participants
|
|
Age, Categorical
>=65 years
|
17 Participants
n=50 Participants
|
16 Participants
n=50 Participants
|
33 Participants
n=100 Participants
|
|
Sex: Female, Male
Female
|
13 Participants
n=50 Participants
|
17 Participants
n=50 Participants
|
30 Participants
n=100 Participants
|
|
Sex: Female, Male
Male
|
37 Participants
n=50 Participants
|
33 Participants
n=50 Participants
|
70 Participants
n=100 Participants
|
|
Race and Ethnicity Not Collected
|
—
|
—
|
0 Participants
n=100 Participants • Race and Ethnicity were not collected from any participant.
|
|
Region of Enrollment
United States
|
50 participants
n=50 Participants
|
50 participants
n=50 Participants
|
100 participants
n=100 Participants
|
PRIMARY outcome
Timeframe: BaselineThe average total time (minutes) it took to complete a lateral transfer.
Outcome measures
| Measure |
Group 1: Standard of Care Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
|---|---|---|
|
Time to Complete Lateral Transfer
|
33.40 minutes
Standard Deviation 121.40
|
4.094 minutes
Standard Deviation 1.688
|
PRIMARY outcome
Timeframe: BaselineThe average number of staff members engaged during transfers
Outcome measures
| Measure |
Group 1: Standard of Care Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
|---|---|---|
|
The Number of Staff Involved in a Transfer
|
4.98 staff members
Standard Deviation 0.87
|
4.92 staff members
Standard Deviation 0.88
|
PRIMARY outcome
Timeframe: BaselineThe average weight (kilograms) of participants who underwent a lateral transfer
Outcome measures
| Measure |
Group 1: Standard of Care Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
n=50 Participants
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
|---|---|---|
|
Average Weight of Participants
|
89.47 kilograms
Standard Deviation 22.57
|
86.24 kilograms
Standard Deviation 20.23
|
SECONDARY outcome
Timeframe: BaselinePopulation: A survey was provided to every study clinician who participated in a standard of care lateral transfer or a SimPull lateral transfer. A survey was provided to every study clinician who participated in a standard of care lateral transfer or a SimPull lateral transfer. There were 14 more survey responses in the SimPull group because some of the SimPull transfers required the involvement of more than one of the study clinicians to complete the transfer of the patient.
Number of survey responses where clinicians indicated they were satisfied with the transfer method
Outcome measures
| Measure |
Group 1: Standard of Care Transfer
n=114 Survey Responses
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
|---|---|---|
|
Clinician Satisfaction
Standard of Care-subject moved using the standard of practice lateral patient transfer methods
|
44 Survey Responses
|
—
|
|
Clinician Satisfaction
SimPull Device Transfer-subject moved using the SimPull automated lateral transfer device
|
40 Survey Responses
|
—
|
SECONDARY outcome
Timeframe: BaselinePopulation: A survey was provided to every study clinician who participated in a standard of care lateral transfer or a SimPull lateral transfer. There were 14 more survey responses in the SimPull group because some of the SimPull transfers required the involvement of more than one of the study clinicians to complete the transfer of the patient.
Measured by a post transfer survey where clinicians indicated how likely they feel they are to be injured during lateral patient transfer using standard transfer methods versus SimPull on a scale of "Not at all likely", "Not likely", "Neutral", "Likely", or "Very Likely."
Outcome measures
| Measure |
Group 1: Standard of Care Transfer
n=114 Survey Responses
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the current standard of practice lateral patient transfer methods by nursing staff.
|
Group 2: SimPull Device Transfer
After cardiac catheterization lab or electrophysiology lab procedure, the subject will be moved from one bed to another using the SimPull device.
SimPull Lateral Transfer Device: Automated lateral transfer device
|
|---|---|---|
|
The Number of Survey Responses From Clinicians Who Indicated They Were Very Likely to Experience Injury During Transfers
Standard of Care-subject moved using the standard of practice lateral patient transfer methods
|
0 Survey Responses
|
—
|
|
The Number of Survey Responses From Clinicians Who Indicated They Were Very Likely to Experience Injury During Transfers
SimPull Device Transfer-subject moved using the SimPull automated lateral transfer device
|
2 Survey Responses
|
—
|
Adverse Events
Group 1: Standard of Care Transfer
Group 2: SimPull Device Transfer
Group 3: Clinicians
Serious adverse events
Adverse event data not reported
Other adverse events
Adverse event data not reported
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place