Multi-center Study of Artificial Intelligence Model for Gadolinium-based Contrast Agent Reduction in Brain MRI (MAGNET)
NCT05754476 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 3000
Last updated 2023-03-03
Summary
MAGNET is a multi-center and prospective study to minimize Gadolinium-based Contrast Agent (GBCA) combining novel artificial intelligence (AI) methods with pre-contrast images and/or low-dose images to synthesize virtual contrast-enhanced T1 (vir-T1c) images, based on a large clinical and MRI database and subsequently validated for its clinical value. MRI examinations for patients included T1-weighted images (T1WI) before and after contrast agent administration and at two dose levels: low-dose (10% or 25%) and full-dose (100%), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and diffusion-weighted imaging sequences (DWI) and the computed apparent diffusion coefficient (ADC), all either acquired three dimensional \[3D\] or two dimensional \[2D\]). The standard dose of intravenous gadolinium contrast agent was 0.1mmol/kg(body weight) by manual injection or automatic injection with a high-pressure syringe at a flow rate of 4mL/s.The sequence parameters used for the 3DT1WI scans must be consistent, and the standard for intravenous injection of gadolinium contrast agent is 0.1mmol/kg (body weight), administered either manually or automatically with a high-pressure syringe at a rate of 4mL/s.
Additionally, arterial spin labeling (ASL), amide-proton transfer chemical exchange saturation transfer (APT-CEST), susceptibility-weighted imaging (SWI), or quantitative susceptibility mapping (QSM) can be acquired at the same time if the conditions permit.
Conditions
- Brain Diseases
Interventions
- OTHER
-
Low-dose GBCA levels
MRI examinations for patients at two dose levels: low-dose (10% or 25%)can be chosen.
Sponsors & Collaborators
-
Beijing Tiantan Hospital
lead OTHER
Principal Investigators
-
Yaou Liu, PhD · Study Principal Investigator
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-03-29
- Primary Completion
- 2023-12-31
- Completion
- 2024-12-31
Countries
- China
Study Locations
More Related Trials
-
An Observational Study to Collect Information on the Safety of Gadolinium-Based Contrast Agents in Patients in India
NCT06257277 ·Status: COMPLETED
-
Feasibility of Gadolinium Contrast Reduced Brain MRI: the Potential of Deep Learning
NCT06462924 ·Status: WITHDRAWN ·Phase: PHASE1
-
A Study to Compare How Well Gadoquatrane Works and Its Safety With an Already Available Contrast Agent for MRI in People With Known or Suspected Brain or Spinal Cord-related Problems
NCT05915702 ·Status: COMPLETED ·Phase: PHASE3
-
Detection of Brain Metastases Using a Novel Gadolinium-Weighted MRI Sequence: A Prospective Comparison
NCT07272616 ·Status: RECRUITING
-
Efficacy and Safety Study to Evaluate Gadavist (Gadobutrol) as Contrast Agent in Magnetic Resonance Imaging (MRI) of Brain or Spine Diseases in Chinese Patients
NCT00395460 ·Status: COMPLETED ·Phase: PHASE3
-
An Explainable Neuroradiologist Artificial Intelligence Assistance System for Brain CT and MRI
NCT07167043 ·Status: ENROLLING_BY_INVITATION
-
P03277 Dose Finding Study in Central Nervous System (CNS) Magnetic Resonance Imaging (MRI)
NCT02633501 ·Status: COMPLETED ·Phase: PHASE2
-
Study of New Magnetic Resonance Methods
NCT00001844 ·Status: TERMINATED
-
Multiparametric Diagnostic Model of Thick-section Clinical-quality MRI Data in Detecting Migraine Without Aura
NCT03570086 ·Status: UNKNOWN
-
Glymphatic Kinetics In Healthy Adult Volunteers
NCT03218111 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Gadobutrol 1.0 Molar in Japanese Subjects for CNS Imaging
NCT01660841 ·Status: COMPLETED ·Phase: PHASE3
-
Study to Find the Appropriate Dose of a New Gadolinium-based Contrast Agent (GBCA) for Adults Undergoing Magnetic Resonance Imaging (MRI) for Known or Highly Suspected Brain and/or Spinal Cord Conditions
NCT04307186 ·Status: COMPLETED ·Phase: PHASE2
-
Assessment of the Impact of Gadolinium Injection on the Measurement of the QSM Signal
NCT04906941 ·Status: COMPLETED
-
A Study of a Gadolinium-Based Contrast Agent (GBCA) for Adults Undergoing Magnetic Resonance Imaging (MRI) for Known or Highly Suspected Central Nervous System (CNS) Lesions
NCT07275814 ·Status: RECRUITING ·Phase: PHASE3
-
A New Generation of Magnetoencephalographs for High Speed Functional Brain Imaging
NCT06244472 ·Status: RECRUITING ·Phase: NA
-
A Study of a Gadolinium-Based Contrast Agent (GBCA) for Adults Undergoing Magnetic Resonance Imaging (MRI) for Known or Highly Suspected Body Parts (Non-Central Nervous System) Lesions
NCT07275723 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE3
-
(Withdrawal) AI-Based Low-Dose 3D-DSA Reconstruction
NCT06769867 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Diagnosis and Treatment of Intracerebral Hemorrhage Based on Artificial Intelligence
NCT04951570 ·Status: COMPLETED
-
Clinical Applicantion of Multi-Tracer PET/MR Imaging in Neurological Disorders/Disease
NCT06092125 ·Status: RECRUITING
-
Concordance and Accuracy of MRI in the Detection of Meningiomas: Optimizing Sequences With Low Doses of Gadolinium
NCT04113395 ·Status: COMPLETED
-
MR Image Synthesis With Low Gadobutrol Dose and AI
NCT06224543 ·Status: COMPLETED ·Phase: PHASE1
-
Development of Protocols and Methods for Image Processing and Enhancement of Magnetic Resonance Imaging (MRI) Data.
NCT04942704 ·Status: UNKNOWN
-
Investigation of Hemodynamics and Radiomics Based on High Resolution Magnetic Resonance Imaging for Predicting the Outcomes of Intracranial Dissecting Aneurysm
NCT07335029 ·Status: ACTIVE_NOT_RECRUITING
-
Evaluation of Clinical Decision Support System for Brain Metastasis Using Brain MR Images
NCT05573815 ·Status: UNKNOWN ·Phase: NA
-
Low Field and High Field Magnetic Resonance Imaging Assessments on Pediatric Patients
NCT04629469 ·Status: RECRUITING ·Phase: NA