Evaluation of Different Methods to Measure Muscle Mass and Strength in a Population With Class II/III Obesity

NCT05732363 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 35

Last updated 2025-05-09

No results posted yet for this study

Summary

Rationale: Weight loss therapies should aim to reduce fat mass while preserving both muscle mass and muscle strength. Consequently, there is a need for validated methods to measure muscle mass and strength. Current methods are either expensive and require trained technicians, or have not been validated in populations with class II/III obesity (BMI \> 35 kg/m2). In our previous studies (MUST-MOP and MUSCLE study), we have validated the use of ultrasound (US) for the measurement of lean mass (a proxy for muscle mass) in a population with obesity. These studies showed that the use of US for the measurement of lean mass was feasible, reliable and valid. The aim of the current study is to validate the use of US for the measurement of lean mass after weight loss in a population of bariatric surgery patients.

Objective: Primary objective: To assess the validity of US to measure lean mass after weight loss in a population of bariatric surgery patients.

Secondary Objectives:

* To assess de differences in lean mass between DXA and US in this study compared to the MUSCLE-study.
* To assess how the lean mass has changed after bariatric surgery and the effects of lean mass on total weight loss and resolution of comorbidities
* To assess whether the change in lean mass has an effect on serum levels of markers for muscle mass.

Study design: This study is an observational follow-up study of the MUSCLE study and will take place in the Centre Obesity Northern-Netherlands (CON) at the Medical Centre Leeuwarden (MCL).

Study population: The population will consists of participants, who have participated in the MUSCLE study and have received bariatric surgery at the CON / MCL.

Main study parameters/endpoints: The main parameters of this study are: lean mass measured by DXA and US. The main endpoint of this study is the validity of the US measurement of lean mass compared to DXA.

Nature and extent of the burden and risks associated with participation, benefit and group relatedness: There are no direct benefits for the participants. However, the results of this study can help to further validate the ultrasound as a cheaper and more accessible method to measure muscle mass. This can potentially be used in standard clinical care to assess muscle mass of patients during weight loss.

• The additional time investment: during first year follow-up appointment approximately 30 minutes.

The risks of most test are minor, even the small amount of radiation exposure, which means the risks and burden of this study outweigh the potentially obtainable knowledge.

Conditions

  • Obesity, Morbid

Interventions

DEVICE

Ultrasonography

The US muscle measurement will be performed with the handheld portable Philips Lumify Sonography connected to a Samsung tablet. The measurement will take approximately 5-10 minutes. A seven-point measurement has to be performed based on the seven-site Jackson Pollock Generalized Prediction Equations for circumference and skinfold thickness measurements.6,7

RADIATION

Dual-energy X-ray Absorptiometry

The brand of the DXA scanner is the Hologic Discovery A, which has a weight limit of 204 kilograms. During the DXA scan, patients will be exposed to radiation, which is approximately 0.2 micro Sievert (µSv) for measuring body composition. For comparison: the average amount of background radiation per hour is approximately 0.23 µSv. The DXA body composition scan will be performed according to standard protocol by a specialized technician.

Sponsors & Collaborators

  • Frisius Medisch Centrum

    lead OTHER

Principal Investigators

  • Marloes Emous, PhD · Frisius Medisch Centrum

Eligibility

Min Age
18 Years
Max Age
67 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2023-06-27
Primary Completion
2024-11-01
Completion
2025-01-01

Countries

  • Netherlands

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.