Comparison of Two Different Pupillometer
NCT05717244 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 100
Last updated 2024-06-24
Summary
With the development of refractive surgery, the size of scotopic pupil has been widely concerned by clinicians. Historically, the measurement of pupil size included the use of a pupil ruler, which is known for its drawback of being very subjective and lacking precision. While infrared pupillometry devices such as OPD-Scan III and Sirius are available for accurately and reliably measuring pupil size. Nevertheless, the aforementioned equipments are costly and cumbersome to move in terms of screening and field trial logistics settings. And 2WIN-S is a portable refractor, it can in a short period of diopter and scotopic pupil size and other data obtained at the same time. Therefore, the aim of this study was to compare the agreement between 2WIN-S and OPD-Scan III in measuring scotopic pupil size and the repeatability of 2WIN-S.
Conditions
- Measurement of Pupil Diameter
Interventions
- DEVICE
-
2WIN-S
Determining pupil diameter by 2WIN-S
- DEVICE
-
OPD
Determining pupil diameter by OPD
Sponsors & Collaborators
-
He Eye Hospital
lead OTHER
Principal Investigators
-
Emmanuel E Pazo, MD, PhD · He Eye Hospital, Shenyang, China
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-09-01
- Primary Completion
- 2023-12-20
- Completion
- 2024-02-01
Countries
- China
Study Locations
More Related Trials
-
Imaging of Corneal and Crystalline by Near Infrared Retro-illumination
NCT05717543 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study and Preliminary Application Study on Iris OCTA
NCT03631108 ·Status: UNKNOWN
-
The Correlation Between Pupil Size and Retinal Nerve Fibers Changes in Pseudoexfoliation Syndrome.
NCT06588816 ·Status: NOT_YET_RECRUITING
-
Investigating the Retardation Effect of OCTA-Guided Targeted Photocoagulation on the Progression of Non-Perfusion Areas in Diabetic Retinopathy Patients
NCT06821633 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Retinal Perfusion Between Diabetic and Non-diabetic Patients With OCT Angiography After Cataract Surgery.
NCT03903965 ·Status: COMPLETED
-
Repeatability and Reproducibility of Cirrus HD-OCT Macular Retinal Pigment Epithelium Elevation
NCT01890174 ·Status: COMPLETED
-
Prospective Comparison of Cirrus Versus Stratus Ocular Coherence Tomography for Different Retinal Pathology.
NCT00731458 ·Status: COMPLETED ·Phase: NA
-
High-throughput Large-model-based AI-assisted Diagnosis Using OCT
NCT07249307 ·Status: NOT_YET_RECRUITING
-
Evaluation of Objective Perimetry Using Pupillometer
NCT01021982 ·Status: COMPLETED
-
The Diagnostic Performance of BMO-MRW and RNFL Thickness and Their Combinational Index Using Artificial Neural Network
NCT03257020 ·Status: COMPLETED
-
Determination of Physical Parameters Relevant to Ophthalmic Lasers
NCT02023073 ·Status: RECRUITING
-
Measurment of Optic Disc Parameters, RNFL Thickness and Ganglion Cell Complex in Myopic, Hypermetropic and Emmetropic Patients Using OCT and Axial Length Measurments
NCT07241806 ·Status: NOT_YET_RECRUITING
-
"Predicting Glaucoma Progression With Optical Coherence Tomography Structural and Angiographic Parameters".
NCT04646122 ·Status: UNKNOWN
-
Evaluation of Diabetic Retinopathy Using Ultra-Widefield Fundus Images Compared With Two-Field Fundus Images
NCT05836194 ·Status: COMPLETED
-
Analysis of Risk Factors of Diabetic Retinopathy
NCT06154746 ·Status: NOT_YET_RECRUITING
-
oCular Examination at Cell RESolution With Optical TransmissionTomography
NCT06976034 ·Status: RECRUITING ·Phase: NA
-
Optos Versus Indirect Ophthalmoscopy for ROP Screening Examination (Optos vs BIO Study)
NCT04292015 ·Status: COMPLETED ·Phase: NA
-
Single-center Study Measuring OSDI Dry Eye Score in Patients Undergoing an Anti-VEGF Induction Protocol
NCT06262737 ·Status: RECRUITING
-
MP3 (Microperimeter 3) Reproducibility in Healthy Subjects and Macular Patients
NCT02941406 ·Status: UNKNOWN
-
Early Vision Screening in High-risk Children
NCT02678468 ·Status: UNKNOWN
-
Measurement of the Oxygen Saturation in the Retinal Vessels With Oxymap
NCT02318641 ·Status: UNKNOWN
-
Retina Projection System Trials for Low Vision People
NCT00219427 ·Status: COMPLETED
-
Assessment of the Occuity PM1 Pachymeter
NCT05895617 ·Status: COMPLETED
-
Pupil Dynamics and Color Vision for the Detection of Eye Diseases
NCT04909398 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Repeatability and Reproducibility of OCTA Image Quality With the Heidelberg Engineering SPECTRALIS With OCT Angiography Module
NCT03530449 ·Status: TERMINATED