PRINCE22 System Complete Performance Study
NCT05656313 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 22
Last updated 2023-03-27
Summary
The investigation proposes to compare a narrow reference beamformer to a novel beamformer approach, when the talker is not in front of the hearing aid user and in the presence of background noise. The beamformer effect will be determined in terms of speech intelligibility, listening effort and ability to multitask when the talkers are located on the side or in the back.
Conditions
- Hearing Loss, Bilateral
- Hearing Loss, Unilateral
Interventions
- DEVICE
-
Measures of speech intelligibility in a noisy situation with speech from the side and from behind (measured with CC-OLSA Test)
The Concurrent OLSA test (CC-OLSA) is a speech recognition test with three turn-taking talkers presenting sentences of the Oldenburg sentences test at fixed signal-to-noise ratios. CC-OLSA is the only one-talker-at-a-time speech test that is sensitive at the desired SNR and uses sentences with an intelligibility function with slopes of 10-17 %/dB.
- DEVICE
-
Measures of the subjective speech recognition threshold in a noisy situation with speech from the side and from behind (measured with HEISS test)
The measure of the subjective speech recognition threshold is an alternative procedure to evaluate the subjective speech intelligibility in different listening conditions. The subjective speech recognition threshold is defined as the speech presentation level of running speech needed to just follow conversation. Subjects have to adjust the presentation level of speech so that they are just able to understand the speech, using a slider on a touch screen. This adjustment is repeated 10 times. Each adjustment results in a value for the subjective speech recognition threshold in dB SNR. The outcome measure is the mean value of the 10 repetitions. The HEISS-Test will be repeated four times for the secondary objective: test for 2 test conditions (Reference, novel approach) against 2 target directions (better ear side, back).
- DEVICE
-
Ability to multitask in the auditory and visual domains in noisy situation with speech from the side and from behind (Multitask test)
This test uses a dual-task-paradigm assessing vigilance for auditory and visual triggers concurrently. The primary task is to listen to a novel (Harry Potter) and respond on two trigger words by pressing the appropriate button (one in each hand). The secondary task is to observe a monitor showing a sequence of random signs and respond on a target sign by pressing both buttons. The test includes at least 100 triggers (50 auditory, 50 visual) and takes 10 minutes per condition (side vs. back; novel approach vs. reference; 40 minutes in total). The multitask test will be repeated four times for the secondary objective: 2 conditions (Refrence, novel approach) against 2 target directions (better ear side, back). Following data are provided from each multitask Test measure: (1) subjective rating of the perceived ability to perform the visual and the auditory test simultaneously. (2) reaction times to auditory and visual tasks, and (3) accuracy.
- DEVICE
-
Measure of subjective speech intelligibility and listening effort in noisy situation with speech from the side and from behind (subjective assessment; 100-point scale)
In addition to the tests mentioned above a subjective assessment will be used to determine the subjective perception as this measure is often a good indication for clinical relevance. For this purpose, the same speech material as used in the HEISS-test is presented by a loudspeaker in the same noisy environment as in the other three tests. The subjects rate his/her perception of the presented speech using a questionnaire on the dimensions "listen effort and speech intelligibility". The subject will rate his perception on the 100 point scale with pencils with different colors to get either absolute and relative ratings. The subjective assessment will be repeated four times for the secondary objective: 2 test conditions (Rference and novel approach) against 2 target directions (better ear side, back). Following data are provided from assessment: rating on a 100-point scale per condition and per dimension.
Sponsors & Collaborators
-
Sonova AG
lead INDUSTRY
Principal Investigators
-
Matthias Latzel · Sonova AG
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-11-03
- Primary Completion
- 2023-01-31
- Completion
- 2023-02-17
Countries
- Germany
Study Locations
More Related Trials
-
Evaluating a Deep Neural Noise-Reduction Algorithm for Hearing Aids
NCT07287774 ·Status: RECRUITING ·Phase: NA
-
Perceptual Consequences of Cochlear Implant Electrode-neuron Interfaces
NCT05867173 ·Status: RECRUITING ·Phase: NA
-
Speech Intelligibility in Noise Using the Hearing in Noise Test (HINT)
NCT01309503 ·Status: UNKNOWN
-
Assessment of Bimodal Contribution in Adult Cochlear Implant Users
NCT02331017 ·Status: UNKNOWN ·Phase: NA
-
Cochlear Implant Speech and Non-speech Sound Recognition
NCT03661970 ·Status: TERMINATED
-
fNIRs, Listening Effort, and Speech Intelligibility
NCT05330585 ·Status: UNKNOWN ·Phase: NA
-
Physiological, Behavioural and Subjective Measures of Listening Effort
NCT03761927 ·Status: COMPLETED ·Phase: NA
-
Implantation of the HiRes90K™ Advantage Cochlear Implant With HiFocus™ Mid-Scala and Development of a Combined Electric and Acoustic Stimulation Technology in Adults With Partial Deafness
NCT02189798 ·Status: TERMINATED ·Phase: NA
-
Optimization of Hearing Performance in the Subject Implanted
NCT05325450 ·Status: UNKNOWN ·Phase: NA
-
This Clinical Investigation Assesses the Safety and Performance of a New Beamformer for MED-EL Cochlear Implant Recipients.
NCT07213505 ·Status: RECRUITING ·Phase: NA
-
Benefits From Bimodal Fittings With Cochlear Implant and Hearing Aid vs Bilateral Hearing Aids
NCT04919928 ·Status: UNKNOWN ·Phase: NA
-
Exploration of the Functional Effect of Different Hearing Aid Noise Reduction Algorithms in an Ecologically Valid Conversational Situation
NCT06992310 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Improving Speech in Noise Perception for Individuals With Age-related Hearing Loss
NCT07192757 ·Status: RECRUITING ·Phase: NA
-
Assessing Speech Perception and Amplification Benefit During Infancy
NCT05653999 ·Status: COMPLETED
-
Perimodiolar Implant Performance in Adults With Low-Frequency Residual Hearing
NCT04741009 ·Status: COMPLETED ·Phase: NA
-
Listening Effort in Cochlear Implant Users
NCT06516575 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Artificial Intelligence-Integrated Hearing Aids for Individuals with Hearing Loss
NCT06792110 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Speech Performance and Clinic Efficiency With Remote Care Compared With Standard of Care in Adults With a Cochlear Implant in the First 12 Months Post-activation
NCT05552118 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
fNIRS, Listening Effort, and Motivation
NCT05893992 ·Status: COMPLETED ·Phase: NA
-
Asymmetrical Directionality With Bimodal Systems.
NCT05067751 ·Status: UNKNOWN
-
Characterisation of Low Frequency Hearing and Vestibular Function in Patients Undergoing Cochlear Implantation
NCT06021132 ·Status: ACTIVE_NOT_RECRUITING
-
Measuring Comfort and Clarity With Low Gain Feature in Pediatric Hearing Aid Users
NCT05150964 ·Status: COMPLETED ·Phase: NA
-
Assessment of Novel Sound Changing Principles in Hearing Instruments to Determine Their Application - 2018_12
NCT03554577 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Hearing Preservation in Adults With Partial Low-Frequency Hearing Implanted With the HiFocus™ Mid-Scala Electrode
NCT01959152 ·Status: TERMINATED ·Phase: NA
-
Retrospective Analysis of Long-term Speech Performance in Cochlear Implant Recipients Using Electro-acoustic Stimulation
NCT06301568 ·Status: COMPLETED