Evaluate the Safety and Efficacy of Intracoronary Lithotripsy Balloon Catheter and Intracoronary Lithotripsy Apparatus

NCT05649488 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 184

Last updated 2023-04-13

No results posted yet for this study

Summary

This is a prospective, multi-center, single-group target value clinical trial, which will be carried out in many clinical trial institutions in China. A total of 184 subjects (70 of them are OCT subgroups) are planned to be enrolled, all subjects were treated surgically with intracoronary lithotripsy using a balloon dilatation catheter and intracoronary lithotripsy apparatus after a single-group registration, clinical follow-up was carried out within 7 days after operation or before discharge, 1 month and 6 months after operation. The success rate of operation was taken as the main end point to verify the effectiveness of balloon dilatation catheter and intracoronary lithotripsy apparatus.

Conditions

Interventions

DEVICE

Intracoronary lithotripsy balloon catheter and Intracoronary lithotripsy apparatus

Introduction: After the preparation, release the intracoronary lithotripsy balloon catheter to the area to be treated and release the shock wave pulse for treatment. After the balloon reaches the predetermined position, use angiography to lock the position and fill the balloon to 6 atm. After the shock wave pulse therapy, the balloon was expanded to 8 atm according to the balloon compliance table and lasted for 10s. After the treatment, unload the balloon pressure, wait for the blood flow to recover, and repeat the second treatment after an interval of one minute, two cycles, releasing a total of 20 shock wave pulses as a treatment cycle. Therapeutic apparatus specification: IVL-HVG-C01; Specifications of balloon catheter: C20012, C20015, C22512, C22515, C25012, C25015, C27512, C27515, C30012, C30015, C32512, C32515, C35012, C35015, C37512, C37515, C40012, C40015

DEVICE

Dragonfly Opstar Imaging Catheter

OCT (optical coherence tomography) measurement using Dragonfly Opstar Imaging Catheter was performed in the OCT subgroup before or after the treatment of intracoronary lithotripsy balloon catheter and intracoronary lithotripsy therapeutic instrument, or after stent placement.

Sponsors & Collaborators

  • Shanghai Bluesail Boyuan Medical Technology Co., Ltd.

    lead INDUSTRY

Principal Investigators

  • Yaling Han, Ph.D · The General Hospital of Northern Theater Command

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2023-02-09
Primary Completion
2024-12-01
Completion
2025-09-22

Countries

  • China

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05649488 on ClinicalTrials.gov