Artificial Pancreas With Carbohydrate Suggestion for Patients With Type 1 Diabetes Prone to Hypoglycemia

NCT05628662 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 12

Last updated 2022-11-29

No results posted yet for this study

Summary

Achieving near-normoglycemia has been established as the main objective for most patients with Type 1 Diabetes (T1D). Automated insulin delivery (AID) systems, the so-called artificial pancreas (AP) or closed-loop systems, may represent the ideal solution, especially for patients not reaching the therapeutic goals with multiples doses of insulin or open-loop delivery systems. Despite the advances in recent years that have proven the efficacy and safety of these devices in clinical trials and clinical practice settings, such evidence cannot be extrapolated to highly unstable patients, as problematic hypoglycemia remains an exclusion criterion in most of the trials.

The SAFE-AP system is a single-hormone hybrid closed-loop controller based on a proportional derivative with an insulin feedback controller that integrates a safety layer with insulin-on-board constraints and sliding mode reference conditioning. The hybrid closed-loop system includes a second safety feedback loop with a controller that triggers carbohydrate recommendations to the patient. Both control loops are coordinated to ensure that the counter-regulatory effect of rescue carbohydrates is not counteracted with insulin. Such system has been previously proven effective in unannounced exercise, one of the main challenges in AID systems development. Additionally, the algorithm has been recently tailored to achieve a better control in the subgroup of T1D patients prone to hypoglycemia.

In this project, a rigorous clinical testing of the SAFE-AP system will be carried out in 12 patients with T1D and problematic hypoglycemia, despite treatment with continuous subcutaneous insulin infusion. The safety and performance of the system will be evaluated in a 32-hour pilot study, including 4 meals, one overnight period and 2 unannounced aerobic exercise sessions. The study will be performed in a hospital setting with the on-site supervision of a specialized nurse and a diabetologist, as well as an engineer in remote control.

Conditions

  • Type 1 Diabetes Mellitus Prone to Hypoglycemia

Interventions

DEVICE

Automated Insulin Delivery System (SAFE-AP)

Each subject will undergo a 32-hour in-hospital study, including 4 meals (60 grams of carbohydrates each, except 50 grams for breakfast), one overnight period and 2 unannounced aerobic exercise sessions. Each exercise session consists of three 15-minute sets on a cycle ergometer at 70% of maximum heart rate with 5 minutes of rest between sets.

Sponsors & Collaborators

  • Universitat Politècnica de València

    collaborator OTHER
  • Universitat de Girona

    collaborator OTHER
  • Hospital Clinic of Barcelona

    lead OTHER

Principal Investigators

  • Jorge Bondia, PhD · Universitat Politècnica de València

  • Josep Vehí, PhD · Universitat de Girona

  • Ignacio Conget, MD PhD · Hospital Clinic of Barcelona

  • Marga Giménez, MD PhD · Hospital Clinic of Barcelona

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-10-22
Primary Completion
2022-04-06
Completion
2022-04-06

Countries

  • Spain

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.