Continuous Glucose Monitoring in Intensive Care Unit
NCT05585801 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 500
Last updated 2024-03-05
Summary
Glucose control in ICU patients is challenging and exerts high burden on the nursing staff. Continuous glucose monitors (CGM) are now approved and widely available in the outpatient setting for patients with diabetes mellitus. However, only minimal evidence on CGM performance, reliability and benefit in achieving desired glucose control in the intensive care setting has been gathered so far.
The objective of this study is to assess whether the use of CGM helps to maintain blood glucose levels within the time in range recommended for patients in the intensive care.
In addition, accuracy of the sensor will be evaluated and compared to measurements of blood glucose by standardized biochemistry methods.
Conditions
- Blood Glucose
- Critical Care
Interventions
- DEVICE
-
Dexcom G6 continuous glucose monitor
Continuous glucose monitor will be used to measure interstitial glucose and aid in guiding the insulin therapy to achieve target blood glucose range of 6-10 mmol/l. In the control group, blood glucose will be measured according to standards of care and a blinded continuous monitor will be used to compare the time i range between the arms.
- DIAGNOSTIC_TEST
-
Blood glucose measurements according to standards of care
Blood glucose will be measured using point of care glucose meter and standard biochemistry methods. Blinded CGM will be applied to obtain continuous glucose values for post-hoc comparison.
Sponsors & Collaborators
-
Institute for Clinical and Experimental Medicine
lead OTHER_GOV
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-11-01
- Primary Completion
- 2025-12-31
- Completion
- 2026-12-31
Countries
- Czechia
Study Locations
More Related Trials
-
Continuous Glucose Monitoring System: Accuracy and Prognostic Value in Critically Ill Patients
NCT07108179 ·Status: ENROLLING_BY_INVITATION
-
The Performance of Dexcom G6 Glucose Monitoring in Critically Ill Patients
NCT05255783 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring of Hospitalized Patients With Diabetes
NCT04230694 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety of the Dexcom™ G6 Continuous Glucose Monitoring System
NCT02880267 ·Status: COMPLETED ·Phase: NA
-
Effect of Real-time Continuous Glucose Monitoring on Glucose Control and Outcomes of Critically Ill Patients
NCT01992965 ·Status: UNKNOWN ·Phase: NA
-
Use of Continuous Glucose Monitors in Coronavirus Disease 2019 ICU and Potential Inpatient Settings
NCT05343624 ·Status: COMPLETED ·Phase: NA
-
Dexcom G6 Intervention Study
NCT03877068 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety of the Dexcom G6 Continuous Glucose Monitoring System in Non-Critically Ill Patients in the Inpatient Setting
NCT04879693 ·Status: UNKNOWN ·Phase: NA
-
Continuous Glucose Monitoring System in Intensive Care Unit
NCT01995994 ·Status: COMPLETED
-
The Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients
NCT07201155 ·Status: COMPLETED
-
Secondary Care - Continuous Glucose Monitoring
NCT03487887 ·Status: COMPLETED
-
Dexcom G6 Continuous Glucose Monitoring in Hemodialysis
NCT04217161 ·Status: UNKNOWN ·Phase: NA
-
Continuous Glucose Monitoring in Hospitalized Patients With Diabetes Mellitus
NCT04653454 ·Status: COMPLETED ·Phase: NA
-
The Use of a Continuous Glucose Monitoring System (Dexcom G6) in Hospitalized Patients for Acute Care
NCT04385862 ·Status: WITHDRAWN
-
A Study to Evaluate Continuous Glucose Monitor in Hospitalized, Post-operative Patients With Diabetes Mellitus
NCT04845685 ·Status: SUSPENDED ·Phase: NA
-
Use of CGM in Kidney Transplant Recipients
NCT04783441 ·Status: RECRUITING ·Phase: NA
-
Real-time Continuous Glucose Monitoring in Diabetic Cardiothoracic Surgery Patients
NCT00878891 ·Status: TERMINATED ·Phase: NA
-
Continuous Glucose Monitoring (CGM) in Subjects With Type 2 Diabetes
NCT01341067 ·Status: COMPLETED
-
CGM Use in COVID19 Patients (Infection With Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2))
NCT04756141 ·Status: COMPLETED ·Phase: NA
-
Inpatient Use of Personal Continuous Glucose Monitor (CGM) to Improve Diabetes Mellitus Control
NCT07006480 ·Status: RECRUITING ·Phase: NA
-
Remote Glucose Monitoring System in Hospitalized Patients With Diabetic Ketoacidosis (DKA)
NCT05439928 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring for Outpatient Diabetes Management After Hospital Discharge
NCT06852950 ·Status: RECRUITING ·Phase: NA
-
Continuous Glucose Monitoring in Critically Ill
NCT00707434 ·Status: TERMINATED ·Phase: NA
-
The Impact of a Predictive Hypoglycaemia Alert Function in Physical Activity for People With T1DM
NCT04142944 ·Status: COMPLETED ·Phase: NA
-
Dexcom G6 Observational Study
NCT03832907 ·Status: COMPLETED ·Phase: NA