Development and Application of a New Balloon Catheter for Intraairway Hemostasis
NCT05554731 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 200
Last updated 2022-09-26
Summary
Massive hemoptysis is a serious disease of respiratory system, which seriously endangers the life of patients.
There are obvious difficulties in the treatment of hemoptysis. In the traditional treatment, patients still have the risk of massive hemoptysis and suffocation, and the risk control in the treatment process cannot be ensured.
Intra - airway interventional therapy, especially the hemostatic technique of intra - airway balloon catheter, is an important means to control the risk of hemoptysis.
However, the current intraairway balloon catheter therapy technology is immature, complicated and difficult to operate, and the cost is high. There is a lack of special balloon for hemostasis, and the balloon borrowed for other purposes cannot meet the needs of hemoptysis treatment.
Therefore, it is urgent to develop a new balloon catheter for airway hemostasis, which has simple technical operation, easy to master and popularize, efficient and safe function and structure.
According to this requirement, this project designed and developed hemostatic balloon catheter with multiple functions such as self-guiding, anti-displacement, anti-leakage and detachable rear end, so as to make the treatment of massive hemoptysis more safe and effective, simpler and faster, so as to be widely applied in clinical practice.
Conditions
- Hemoptysis
Interventions
- DEVICE
-
a New Balloon Catheter for Intraairway Hemostasis
In the treatment group, the new balloon catheter was inserted in three steps, that is, the tracheoscope was inserted into the airway to remove the blood in the airway and find the target bronchus.The new airway hemostatic balloon catheter was directly inserted through the tracheoscopy biopsy channel, and then directly inflated and fixed after positioning.Then exit the tracheoscope directly to complete.
- DEVICE
-
Traditional Therapy
A six-step technique was adopted to place the traditional balloon catheter, that is, the tracheoscope was entered to find the target bronchus, the guide wire was inserted through the biopsy channel, the tracheoscope was exchanged to exit the tracheoscope, the catheter was entered through the guide wire exchange, the tracheoscope was re-entered, the catheter was positioned, inflated and fixed, and the tracheoscope was withdrawn.
Sponsors & Collaborators
-
First Affiliated Hospital of Wenzhou Medical University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-10-01
- Primary Completion
- 2023-10-30
- Completion
- 2023-10-30
Countries
- China
Study Locations
More Related Trials
-
Cutting Balloon Study
NCT01205568 ·Status: COMPLETED ·Phase: NA
-
Wedge NC - Scoring Balloon Dilatation Catheter
NCT06214247 ·Status: COMPLETED ·Phase: NA
-
Paclitaxel Eluting Balloon Catheter in Coronary De-novo Lesions Treatment in China
NCT03466749 ·Status: UNKNOWN ·Phase: NA
-
Study Evaluating the Safety and Efficacy of Tri-wire Balloon for Treatment of Dysfunctional AV Fistula
NCT04393688 ·Status: UNKNOWN ·Phase: NA
-
A Study of The Femoral Popliteal Artery Treated With LEGFLOW OTW
NCT02965677 ·Status: UNKNOWN ·Phase: NA
-
Drug Coated Balloons vs Plain Balloons for the Management of Dysfunctional Dialysis Fistula
NCT03189667 ·Status: TERMINATED ·Phase: NA
-
Safety and Efficacy of Balloon Pulmonary Angioplasty in China
NCT04206852 ·Status: RECRUITING
-
A Study of Endovascular Treatment of Femoropopliteal Arterial Occlusive Lesion With Drug-Coated Balloon
NCT04826705 ·Status: ACTIVE_NOT_RECRUITING
-
DCB Versus Primary Selective Stenting in TASC C/D Femoropopliteal Artery Disease
NCT05517291 ·Status: RECRUITING ·Phase: NA
-
Interventional Treatment of Residual Pulmonary Hypertension in Patients After Pulmonary Thromboendarterectomy
NCT02745106 ·Status: UNKNOWN ·Phase: PHASE2
-
Post-marketing Study in Femoral Popliteal Artery of Drug Coated Balloon Used for Treatment of Lower Limb Ischemia
NCT05498740 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study on the Effectiveness and Safety Evaluation of Directional Atherectomy Combined With Drug-coated Balloons
NCT04986098 ·Status: UNKNOWN
-
Acostream Use in Patients With High Risk and Intermediate-risk Acute Pulmonary Embolism
NCT06946732 ·Status: RECRUITING ·Phase: NA
-
Drug Coated Ballon in Critical Limb Ischemia
NCT04737291 ·Status: UNKNOWN ·Phase: NA
-
Efficacy & Safety of LOBO™ Vascular Occlusion Device for Embolization of Pulmonary Arteriovenous Malformations
NCT06735976 ·Status: RECRUITING ·Phase: NA
-
Atherectomy and Drug Coated Balloon for the Treatment of Arterio-Venous Graft Stenosis
NCT04627051 ·Status: UNKNOWN ·Phase: NA
-
The Clinical Application of Peripheral Embolization Coil Systems in Arteriovenous Embolization Within the Peripheral Vasculature
NCT07156409 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Post-Market Study of Drug-Coated Peripheral Balloon Dilatation Catheter in Treating Femoropopliteal Artery Stenosis or Occlusive Lesions.
NCT07187128 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease
NCT05509296 ·Status: COMPLETED ·Phase: NA
-
Jetstream in Treatment of Occlusive Atherosclerotic Lesions in the SFA and/or PPA
NCT03455855 ·Status: COMPLETED ·Phase: NA
-
A Trail of Drug-coated Balloon Treating Below The Knee Arterial Diseases
NCT05415995 ·Status: UNKNOWN ·Phase: NA
-
Restenosis Following Paclitaxel Eluting Balloon Angioplasty of Hemodialysis Access Stenosis
NCT01001676 ·Status: COMPLETED ·Phase: PHASE2
-
Balloon Dilation Methods for Benign Esophageal Stricture
NCT04730076 ·Status: WITHDRAWN ·Phase: NA
-
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
NCT04242134 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Study of Below The Knee Arteries' Stenosis or Occlusion Treated With LEGFLOW OTW
NCT02962232 ·Status: UNKNOWN ·Phase: NA