A Highly Portable Device for Assessment of Mild Traumatic Brain Injury in Deployed and Far-Forward Settings
NCT05527041 · Status: ENROLLING_BY_INVITATION · Type: OBSERVATIONAL · Enrollment: 1600
Last updated 2025-07-31
Summary
The purpose of this study is to develop a highly portable, ruggedized diagnostic tool for concussion, EyeBOX Lens (EBLens), that can be utilized in deployed field and far-forward settings. The EBLens will be based on a concussion diagnostic algorithm from the FDA cleared EyeBOX device, developed by Oculogica, and eye-tracking data collected from a wearable set of eye-tracking glasses, developed by Adhawk Microsystems. Once the EBLens is prototyped, an algorithm for diagnosing concussion will be developed that is specifically appropriate for the EBLens via a case-control clinical study comparing 100 concussed to 100 non-concussed subjects (Phase I). Participants, age 18-35 years, will be recruited from the KACH research team and affiliated providers and clinical sites. Concussed individuals will be assessed within 72 hours of concussion. Demographics, basic medical history, symptom severity, a visio-vestibular exam and the EBLens scan will be collected on both injured cases and uninjured controls at a single time point.
The algorithm and the EBLens will be validated in a subsequent, prospective cohort validation study (Phase II) designed for FDA submission. The correlation of the EBLens output with resolution of symptoms will also be observed in longitudinal follow-up of concussed participants in the validation study. The participant population for this study will be cadets recruited from the USMA and young athletes recruited from affiliated sites during baseline concussion testing. Participants will be assessed at baseline at the start of their academic year or sports season. Those participants who experience a concussive injury will be assessed again at three time points; 1) within 72 hours of injury, 2) weekly until and at the time of initiation of a graded return to activity protocol, and 3) upon clearance for unrestricted RTP/RTD.
Conditions
- Concussion, Brain
- Mild Traumatic Brain Injury
Interventions
- DEVICE
-
EyeBOX Lens (EBLens)
The investigational device, EBLens, consists of eye-tracking scanners and sensors, developed by AdHawk Microsystems, embedded into a rugged pair of eye-glasses. The subject will wear the EBLens form factor while seated about 40 cm from a small handheld computer screen. The subject will be instructed to watch a video on the screen, while trying not to move their head. The operator will then initiate the EBLens test sequence. During this test a video will be displayed on only a portion of the screen (aperture about 1/9 the size of the screen) for 90 seconds. The video aperture will begin in the upper left corner, and, after 10 seconds, moves in a clockwise direction around the screen for 2 cycles, each taking 40 seconds. During the scan, the following data are collected at a frame rate from 100 to 500 Hz: * Gaze coordinates * Pupil sizes * Accelerometer data * Gyroscopic data * Rotation data * Blink data
Sponsors & Collaborators
-
Congressionally Directed Medical Research Programs
collaborator FED -
Oculogica, Inc.
lead INDUSTRY
Principal Investigators
-
Kenneth Cameron, PhD · Keller Army Community Hospital
-
Christina Master, MD · Children's Hospital of Philadelphia
-
Sadie Buboltz-Dubs, PhD · University of Wisconsin - Green Bay
Eligibility
- Min Age
- 17 Years
- Max Age
- 35 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-07-01
- Primary Completion
- 2025-08-01
- Completion
- 2025-09-26
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Spectacles Lens in Concussed Kids
NCT03123822 ·Status: TERMINATED ·Phase: NA
-
Assessment of Oculomotor, Vestibular and Reaction Time Response Following a Concussive Event
NCT01832714 ·Status: COMPLETED
-
Mechanisms of Visual Restoration After Occipital Stroke
NCT07134777 ·Status: RECRUITING
-
Rehabilitation Glasses for the Treatment of Hemispatial Neglect
NCT02695927 ·Status: COMPLETED ·Phase: PHASE1
-
Collision Warning Device for Blind and Visually Impaired
NCT03057496 ·Status: COMPLETED ·Phase: NA
-
Environmental Localization Mapping and Guidance for Visual Prosthesis Users
NCT04359108 ·Status: COMPLETED ·Phase: NA
-
EYE-TRAC Advance: Technology Verification (ETA-TV) Cohort 1
NCT02844543 ·Status: COMPLETED ·Phase: NA
-
Repeatability Assessment of Neurovisual Tasks for the Construction of a New Concussion Monitoring Tool (SPORTICARE)
NCT05992194 ·Status: COMPLETED
-
Eyelid Movement Sensor Device- Blinking Characterizing
NCT02309814 ·Status: COMPLETED ·Phase: NA
-
Integrated Eye Tracking and Neural Monitoring for TBI: Optimization
NCT03451058 ·Status: COMPLETED
-
Validation of Clinical Outcome Measures Specific to mTBI-Related Oculomotor Disorders
NCT07282691 ·Status: RECRUITING
-
Non-invasive Diagnostic for Assessing Elevated Intracranial Pressure
NCT03418753 ·Status: COMPLETED
-
Disparity Driven Vergence in Mild Traumatic Brain Injury (mTBI)
NCT03529799 ·Status: TERMINATED ·Phase: NA
-
Evaluation of Eye Movement Tracking Systems for Visual Rehabilitation
NCT00013429 ·Status: COMPLETED ·Phase: PHASE2
-
Eyetracking and Neurovision Rehabilitation of Oculomotor Dysfunction in Mild Traumatic Brain Injury
NCT03319966 ·Status: COMPLETED
-
Study of Binocular Computer Activities for Treatment of Amblyopia
NCT02200211 ·Status: COMPLETED ·Phase: NA
-
Use of Eye Tracking to Aid in Autism Risk Detection
NCT06471504 ·Status: RECRUITING ·Phase: NA
-
mTBI Identification and Monitoring Through Retinal Scanning
NCT06142435 ·Status: RECRUITING
-
Pupillometry for the Prediction of Neurologic Outcomes in Severe Traumatic Brain Injury
NCT02465242 ·Status: UNKNOWN
-
Detection and Prevention of Concussive Injuries With Smart Technology.
NCT04946747 ·Status: UNKNOWN ·Phase: NA
-
Engineering Evaluation of an Eye Movement Monitor Device
NCT05222022 ·Status: COMPLETED ·Phase: NA
-
Eyegaze Systems for Spinal Cord Injury: A Feasibility Study
NCT01943656 ·Status: UNKNOWN ·Phase: PHASE4
-
Intermediate Visual Space Perception
NCT05419713 ·Status: RECRUITING ·Phase: NA
-
Effects of Soccer Heading on Ocular-motor Function and Blood Biomarker
NCT03488381 ·Status: COMPLETED ·Phase: NA
-
Measuring of Neuro-visual Functionality With Ocusweep
NCT02258113 ·Status: UNKNOWN ·Phase: NA