Trial Outcomes & Findings for Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens (NCT NCT05518539)

NCT ID: NCT05518539

Last Updated: 2025-07-18

Results Overview

Recruitment status

COMPLETED

Target enrollment

30 participants

Primary outcome timeframe

1 month postoperatively

Results posted on

2025-07-18

Participant Flow

Participant milestones

Participant milestones
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Overall Study
STARTED
30
Overall Study
COMPLETED
24
Overall Study
NOT COMPLETED
6

Reasons for withdrawal

Reasons for withdrawal
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Overall Study
Lost to Follow-up
6

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=30 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Age, Continuous
65.0 years
STANDARD_DEVIATION 7.7 • n=30 Participants
Sex: Female, Male
Female
20 Participants
n=30 Participants
Sex: Female, Male
Male
10 Participants
n=30 Participants

PRIMARY outcome

Timeframe: 1 month postoperatively

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Distance-corrected Near (40 cm) Visual Acuity
0.00 logMAR
Standard Deviation 00.06

PRIMARY outcome

Timeframe: 3 months postoperatively

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Distance-corrected Near (40 cm) Visual Acuity
0.01 logMAR
Standard Deviation 0.10

SECONDARY outcome

Timeframe: 1 and 3 months postoperative

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Uncorrected Distance (6 m) Visual Acuity
1 Month
0.00 logMAR
Standard Deviation 0.08
Binocular Uncorrected Distance (6 m) Visual Acuity
3 Months
0.02 logMAR
Standard Deviation 0.19

SECONDARY outcome

Timeframe: 1 and 3 months postoperative

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Uncorrected Intermediate (60 cm) Visual Acuity
1 Month
-0.04 logMAR
Standard Deviation 0.08
Binocular Uncorrected Intermediate (60 cm) Visual Acuity
3 Months
-0.08 logMAR
Standard Deviation 0.09

SECONDARY outcome

Timeframe: 1 and 3 months postoperative

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Uncorrected Near (40 cm) Visual Acuity
1 Month
0.04 logMAR
Standard Deviation 0.09
Binocular Uncorrected Near (40 cm) Visual Acuity
3 Months
0.04 logMAR
Standard Deviation 0.12

SECONDARY outcome

Timeframe: 1 and 3 months postoperative

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Corrected Corrected Distance (6 m) Visual Acuity
1 Month
-0.02 logMAR
Standard Deviation 0.07
Binocular Corrected Corrected Distance (6 m) Visual Acuity
3 Months
-0.04 logMAR
Standard Deviation 0.08

SECONDARY outcome

Timeframe: 1 and 3 months postoperative

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Binocular Distance-corrected Intermediate (60 cm) Visual Acuity
1 Month
-0.04 logMAR
Standard Deviation 0.08
Binocular Distance-corrected Intermediate (60 cm) Visual Acuity
3 Months
-0.08 logMAR
Standard Deviation 0.10

SECONDARY outcome

Timeframe: 3 months postoperative

spherical equivalent refraction and astigmatism less than or equal to 0.5 D.

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=48 eyes
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Manifest Refraction
Manifest Refraction Spherical Equivalent
46 eyes
Manifest Refraction
Astigmatism
46 eyes

SECONDARY outcome

Timeframe: 3 months postoperative

The Intraocular Lens Satisfaction questionnaire (IOLSAT). Subjects were asked how often they needed to wear eyeglasses to see at distance, intermediate, and near. The percentage was calculated as (# of subjects responding "Never" or "Rarely") divided by (# of subjects) times 100. A higher percentage is a better outcome.

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Satisfaction Questionnaire
Spectacle independence distance (overall)
24 Participants
Satisfaction Questionnaire
Spectacle independence intermediate (overall)
22 Participants
Satisfaction Questionnaire
Spectacle independence near (overall)
17 Participants

SECONDARY outcome

Timeframe: 3 months postoperative

Questionnaire for Visual Disturbances (QUVID).

Outcome measures

Outcome measures
Measure
The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)
n=24 Participants
Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models) The Clareon™ PanOptix™ Trifocal (toric and non-toric models): Bilateral implantation with the Clareon PanOptix Trifocal (toric and non-toric models)
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by starbursts
3 Participants
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by halos
2 Participants
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by glare
0 Participants
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by haze
0 Participants
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by blurred vision
0 Participants
Visual Disturbances Questionnaire
Bothered quite a bit" or "Bothered very much" by double vision
0 Participants
Visual Disturbances Questionnaire
dark area
0 Participants

Adverse Events

The Clareon™ PanOptix™ Trifocal (Toric and Non-toric Models)

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

T Hunter Newsom

Newsom Eye

Phone: 813-908-2020

Results disclosure agreements

  • Principal investigator is a sponsor employee