Evaluating the InPen in Pediatric Type 1 Diabetes
NCT05515939 · Status: ACTIVE_NOT_RECRUITING · Type: OBSERVATIONAL · Enrollment: 34
Last updated 2025-09-18
Summary
Type 1 Diabetes (T1D) is the most common form of diabetes affecting children, requiring lifelong administration of insulin to prevent complications. The incidence of T1D has increased more among African Americans, Hispanics, and Asian/Pacific Islanders compared to Caucasian youths in the past two decades. Despite advances in insulin delivery systems, fewer black and Hispanic children compared to white children with T1D use insulin pumps. Therefore, most minority children with T1D in urban areas require multiple daily injections (MDI) of insulin which may put them at increased risk of poor glycemic control. Although several factors contribute to worsening glycemic control in adolescents with T1D, studies have shown that missing doses of insulin at mealtimes is a major factor.
Adolescents with T1D who use MDI with a basal-bolus regimen use formulas to calculate insulin doses that involve a four-step process. The complexity of determining insulin doses contributes to inaccuracies in both timing of doses and amount of insulin given, both of which can lead to hyperglycemia and hypoglycemia.
The InPen™ Smart Insulin Pen System (Medtronics) was approved by the FDA for children of all ages with T1D in June 2020. The InPen is a Bluetooth-enabled smart insulin pen that helps with management of insulin dosing and tracking via capture of rapid-acting insulin doses and tracking of insulin in the body through the use of its companion app (free on Apple iOS and Android). The app includes a bolus calculator, which can lead to more accurate insulin dosing, which may improve glycemic control.
The specific benefits of using the InPen include the following: simplifying insulin dose calculations, administering more accurate insulin doses, tracking insulin doses to help prevent hypoglycemia, providing reminders to administer insulin, and storing data in the InPen App that can be easily shared with diabetes healthcare teams to assist with adjusting insulin doses.
The goal of this study is to determine if use of the InPen will improve glycemic control and diabetes numeracy in adolescents with uncontrolled T1D living in urban areas.
Conditions
Interventions
- DEVICE
-
InPen Insulin Pen
The InPen is a reusable smart insulin pen for people living with diabetes. The device uses Bluetooth technology to send dose information to a mobile application. The InPen can be used to deliver insulin, help calculate insulin doses, and estimate carbohydrates for meals
Sponsors & Collaborators
-
Wayne State University
lead OTHER
Eligibility
- Min Age
- 13 Years
- Max Age
- 21 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-09-09
- Primary Completion
- 2025-11-30
- Completion
- 2026-12-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Glucose Response of G-Pen (Glucagon Injection) in Pediatric T1D Patients
NCT03091673 ·Status: COMPLETED ·Phase: PHASE3
-
Transdermal Basal Insulin Patch Study in Type 1 Diabetes
NCT00519623 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Digital Tracking With Auto Data Reporting
NCT06707155 ·Status: COMPLETED
-
Need-driven Treatment of the Patients With Type 1 Diabetes
NCT07128992 ·Status: NOT_YET_RECRUITING
-
Effects of a Remote Patient Monitoring Protocol on Glycemic Control in Adolescents With Type 1 Diabetes
NCT03466398 ·Status: WITHDRAWN ·Phase: NA
-
Glucose Measurement Using Microneedle Patches
NCT02682056 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring in Adolescents With Poorly Controlled Type 1 Diabetes
NCT01586065 ·Status: COMPLETED ·Phase: NA
-
Benefits of Smart Pens in Type 1 Diabetes
NCT06415097 ·Status: NOT_YET_RECRUITING
-
Pilot Study to Verify Effect of Smartpen Coordinated With Glucose Sensor.
NCT06310980 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
InPen User Experience
NCT05029271 ·Status: COMPLETED ·Phase: NA
-
PINIT Study: Primary Intranasal Insulin Trial
NCT03182322 ·Status: COMPLETED ·Phase: PHASE2
-
Assessing the Impact of Control-IQ Technology
NCT04838561 ·Status: COMPLETED
-
The Summer Camp Study 2: Blood Glucose Control With a Bi-Hormonal Endocrine Pancreas
NCT02105324 ·Status: COMPLETED ·Phase: NA
-
Insulin Pump Therapy in Adolescents With Newly Diagnosed Type 1 Diabetes (T1D)
NCT00357890 ·Status: COMPLETED ·Phase: NA
-
Insulin Clamp Ancillary Study for Assessment of Insulin Resistance
NCT02045290 ·Status: COMPLETED ·Phase: PHASE3
-
The Diabetes Prevention Trial of Type 1 Diabetes (DPT-1)
NCT00004984 ·Status: COMPLETED ·Phase: PHASE3
-
Islet Transplantation in Type 1 Diabetics Using the Edmonton Protocol of Steroid Free Immunosuppression
NCT00133809 ·Status: COMPLETED ·Phase: PHASE2
-
Telemedicine Program in Type 1 Diabetes and CSII
NCT02790645 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety Study of the DexCom™ G4 Continuous Glucose Monitoring System in Children and Adolescents With Type 1 Diabetes Mellitus
NCT01185496 ·Status: COMPLETED
-
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
NCT04476472 ·Status: COMPLETED ·Phase: NA
-
Smart MDI Study (CIP343)
NCT06645834 ·Status: COMPLETED ·Phase: NA
-
Specialized Technology Education for Pumps & Pens in Underserved Populations With Diabetes
NCT04550585 ·Status: COMPLETED
-
Impact of the Continuous Measurement of Blood Glucose on Insulin Pump on Child Quality of Life With Type 1 Diabetes
NCT03177096 ·Status: COMPLETED ·Phase: NA
-
The Summer Camp Study: Blood Glucose Control With a Bi-Hormonal Bionic Endocrine Pancreas
NCT01833988 ·Status: COMPLETED ·Phase: NA
-
Flexible, Intensive Insulin Therapy in Patients With Type 1 Diabetes
NCT00595569 ·Status: COMPLETED