The primary purpose of this study is to evaluate the ability of a new contact lens electrode to record a measurable electroretinogram (ERG). ERG sensors in various forms have been in common clinical use for more than 50 years. The ERG sensor that is the subject of this study is the RM Electrode, developed by RetMap, Inc. (project sponsor). The RM Electrode is not yet approved by the FDA. The RM Electrode will be compared to other commercially available electrode
The first Aim of the present study is to compare the functionality of the RM Electrode and other commercially available electrodes. Following standard ERG test protocols, responses will be recorded from ten healthy (normally-sighted) adult subjects using both electrodes (used in random order). The signal quality of the ERG responses obtained from both contact lens electrodes will be compared. Signal quality will be determined by measuring ERG signal amplitudes and calculating signal-to-noise ratios (SNR). Signal-to-noise ratios will be used to establish substantial equivalence. ERG test results will not be used to determine the effect of the devices on the participants.
The second Aim of the present study is to evaluate the risk of ocular irritation caused by use of the RM Electrode compared to other commercially available electrodes. A typical ERG test session lasts 20 minutes. Ten healthy (normally-sighted) adult subjects will wear the RM Electrode on one eye and a commercially available electrode on the other eye, for a total of 60 minutes, in 20-minute sessions with short breaks in between. To determine the effect of the devices on the participants, the eyes will be evaluated for irritation.
Conditions
- Electrode Site Reaction
Interventions
- DEVICE
-
RM Electrode
The RM Electrode is a corneal ERG electrode. The distinguishing features of the RM electrode are that it is a soft contact lens with a recessed electrode (i.e. no metal electrode makes direct contact with the eye). The RM Electrode also has an integral speculum to hold the wearer's eye lids open. The electrode is designed for superior positional stability on the eye during testing. These features work together to improve ERG signal quality.
- DEVICE
-
ERG Jet Electrode
The ERG Jet electrode is an FDA approved, commercially available corneal ERG electrode.
Sponsors & Collaborators
-
University of Illinois at Chicago
collaborator OTHER -
Illinois College of Optometry
collaborator OTHER -
RetMap, Inc
lead INDUSTRY
Principal Investigators
-
Robert Hyde, MD/PhD · UIC Department of Ophthalmology & Visual Sciences
-
Michael Chaglasian, OD · Illinois College of Optometry
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-03-01
- Primary Completion
- 2025-12-31
- Completion
- 2025-12-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Prospective Exploratory Cohort Study on Ganglion Cell Degeneration in Retinitis Pigmentosa Patients
NCT07056738 ·Status: ENROLLING_BY_INVITATION
-
In Depth Observational Clinical Trial Of Retinitis Pigmentosa Patients
NCT05849987 ·Status: NOT_YET_RECRUITING
-
Relation Between Macular and RNFL Thickness Measurement and Quality Grading in OCT
NCT02700750 ·Status: UNKNOWN ·Phase: NA
-
Gene Expression in Patients With Epiretinal Membranes
NCT01946451 ·Status: UNKNOWN
-
OCT Vibrography for Biomechanical Properties of Tissues
NCT05759780 ·Status: RECRUITING ·Phase: NA
-
Fundus Image-guided Focal Electroretinography, Usability Study
NCT05100511 ·Status: COMPLETED ·Phase: NA
-
Selective Retina Therapy With 'R:GEN' in Patients With Central Serous Chorioretinopathy
NCT03758963 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study to Test the Safety and Feasibility of a Brillouin Ocular Analyzer
NCT01775007 ·Status: COMPLETED ·Phase: NA
-
Multifocal Electroretinogram in Normal Egyptian Population
NCT05323032 ·Status: UNKNOWN ·Phase: NA
-
Feasibility Study and Preliminary Application Study on Iris OCTA
NCT03631108 ·Status: UNKNOWN
-
Evaluation of the Retinal Health Monitoring System Thickness Module
NCT04499703 ·Status: COMPLETED
-
Color Vision as a Measure for Inherited Retinal Diseases
NCT01878032 ·Status: COMPLETED
-
Structure and Function of Retinal Disease
NCT05643157 ·Status: COMPLETED ·Phase: NA
-
Microbial Keratitis Sampling for Biomarker Discovery
NCT05888883 ·Status: COMPLETED
-
Epithelial Thickness Map
NCT04578184 ·Status: UNKNOWN ·Phase: NA
-
Optic Neuritis and Ganglion Cell Layer
NCT02864134 ·Status: COMPLETED
-
A Multi-Center Study of Reading Rehabilitation in Macular Disease
NCT00746668 ·Status: COMPLETED ·Phase: NA
-
Computer-based Screening for Diabetic Retinopathy
NCT01614327 ·Status: COMPLETED
-
Electroretinography: Investigation of a Protocol Change
NCT03275441 ·Status: UNKNOWN
-
Robotic OCT for ER Anterior Eye Exams
NCT06566339 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Retinal Oximtery Following Treatment for Diabetic Maculopathy
NCT01549132 ·Status: COMPLETED
-
Quantification of Metamorphopsia in Patients With Epiretinal Membranes
NCT05138315 ·Status: UNKNOWN ·Phase: NA
-
Retinal Imaging With Oblique Illumination
NCT04398394 ·Status: COMPLETED ·Phase: NA
-
A Study to Evaluate the Safety and Performance of the Vista Probe for Vitrectomy Surgery
NCT05689333 ·Status: COMPLETED ·Phase: NA
-
Retinal Imaging by Adaptive Optics in Healthy Eyes and During Retinal and General Diseases
NCT01546181 ·Status: COMPLETED