Muscle strength is the amount of force generated by muscle contraction. It could be measured with an isometric dynamometer. This is a validated tool that could be used to measure Maximal Voluntary Isometric Contraction (MVIC) and Maximal Electrical Induced Contraction (MEIC). It is claimed that higher MEIC values will result in more force gained.
If a current is more tolerated it will be easier to achieve better MEIC values. Tolerance to an electrical stimulation could be measured with the Visual Analogue Scale (VAS). A ratio between Normalized MEIC / VAS is often used, implying that the current is better with a higher ratio.
Muscle fatigue is defined as a temporary loss or decrease in force-generating ability due to previous contractions. It is claimed that medium frequency neuromuscular electrical stimulation (NMES) generates more fatigue than low frequency currents.
Aussie is a medium-frequency alternating current, sinusoidal waveform, 1 KHz carrier frequency.
Neo-Russian is a medium-frequency current, rectangular biphasic symmetrical waveform, 2,5 KHz carrier frequency.
Rectangular Biphasic symmetrical (RBS) waveform is a type of Low Pulsed Current (LPC), claimed to be better than classical Russian Current.
Purpose:
As it has been claimed that LPC is better in MEIC and tolerance, the aim of this study is to compare it with two newer medium frequency currents in terms of MEIC, tolerance and fatigue.
Methods:
Thirty male subjects, right leg dominant, will receive randomly the 3 types of electrical stimulation. Before that, the MVIC will be measured for data normalization.
The MVIC and MEIC will be measured with an isometric dynamometer. In both measurements, subjects will be asked to perform three reps (5 sec work x 120 sec rest) and the best one will be used. Whenever the third one was the best, additional measurements will be taken until a decrease in torque will be obtained to determine the maximum.
To apply Aussie electrical stimulation, an Aussie Sport (Ibramed) will be used. To apply Neo-Russian, a Neurodyn III (Ibramed) will be used. To apply RBS, a Genesy (Globus) will be used.
The VAS will be used to assess tolerance to each treatment. One week later, the subjects will receive, randomly, a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest) of electrical stimulation with the three types of current. The data will be normalized with the MVIC and the reps equal or below 50 % of the first rep will be considered as a fatigue rep.
Conditions
- Healthy
Interventions
- DEVICE
-
Neo-Russian
Subjects will receive Neo-Russian electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.
- DEVICE
-
Aussie
Subjects will receive Aussie electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.
- DEVICE
-
RBS
Subjects will receive RBS electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.
- DEVICE
-
RBS-IPI
Subjects will receive RBS-IPI electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.
- DEVICE
-
HIFEM
Subjects will receive HIFEM electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.
Sponsors & Collaborators
-
Maimonides University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- BASIC_SCIENCE
- Masking
- QUADRUPLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 30 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-08-22
- Primary Completion
- 2022-12-01
- Completion
- 2022-12-01
Countries
- Argentina
Study Locations
More Related Trials
-
Pulsed Current Versus Russian Current Effects in Healthy Young Subjects.
NCT03796117 ·Status: COMPLETED ·Phase: NA
-
Electrical Muscle Stimulation on Muscle Mass, Strength, and Body Composition
NCT06036953 ·Status: COMPLETED ·Phase: NA
-
Stimulation Sites and Fatigue Induced by Neuromuscular Electrical Stimulation in Healthy Individuals
NCT05605210 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Stimulus Phase Duration on Discomfort and Electrically Induced Torque of Quadriceps Femoris
NCT01862393 ·Status: COMPLETED ·Phase: NA
-
Direct Current Neuromuscular Electrical Stimulation for Treatment of Peripheral Neuropathy
NCT05442021 ·Status: COMPLETED ·Phase: NA
-
Neuromuscular Electrical Stimulation in Critically Ill Patients Aged 80 and Over
NCT07127991 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Wearable Garment vs Gel Electrodes for Electrical Muscle Stimulation
NCT07050784 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Effects of Different Montages of tDCS on Muscle Strength in Healthy Adults
NCT04672109 ·Status: COMPLETED ·Phase: NA
-
Percutaneous High Frequency Alternating Current Stimulation in Healthy Volunteers With 30kHz
NCT04884932 ·Status: COMPLETED ·Phase: NA
-
Percutaneous High Frequency Alternating Current Stimulation in Healthy Volunteers
NCT04346719 ·Status: COMPLETED ·Phase: NA
-
Neuromuscular Electrical Stimulation (NMES) in Patients With Intermittent Claudication
NCT02436200 ·Status: COMPLETED ·Phase: NA
-
Effects of Neuromuscular Electrical Stimulation on Exercise Capacity in Respiratory Critically Ill Patients
NCT03083652 ·Status: RECRUITING ·Phase: NA
-
Effect of Different Electric Muscle Stimulation in Patients With Severe Sepsis and Respiratory Failure
NCT01895647 ·Status: TERMINATED ·Phase: NA
-
Evaluation of Muscle Strength by Transcutaneous Electrical Stimulation
NCT03270163 ·Status: TERMINATED ·Phase: NA
-
Use of Neuromuscular Electrostimulation (NMES) for Treatment or Prevention of ICU-Associated Weakness
NCT00709124 ·Status: COMPLETED ·Phase: NA
-
The Efficacy of Neuromuscular Electrical Stimulation to Attenuate Muscle Loss
NCT01521637 ·Status: COMPLETED ·Phase: NA
-
Blood Flow Restricted Electrical Stimulation During Immobilisation
NCT05093985 ·Status: UNKNOWN ·Phase: NA
-
The Effect of a Five Week Electrical Myostimulation Program in Chronic Diseases
NCT01695421 ·Status: UNKNOWN ·Phase: NA
-
Effect of EMS and Strengthening Exercises on Pain, Fatigue and Physical Performance in Motocross Athletes
NCT06300385 ·Status: COMPLETED ·Phase: NA
-
Effect of Eswt on Muscle Architecture
NCT04410705 ·Status: UNKNOWN ·Phase: NA
-
Electrical Stimulation to Strengthen Muscles in the Lower Legs in Patients Requiring Prolonged Mechanical Ventilation
NCT01825135 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of NMES Associated to Vascular Occlusion in Functional Performance and Muscle Hypertrophy in Athlete's
NCT02406339 ·Status: COMPLETED ·Phase: NA
-
TENS in Optimizer(R) Patients
NCT02692690 ·Status: COMPLETED ·Phase: PHASE4
-
Effect of NMES+ on Hamstring Lesion (3a/3b)
NCT05786300 ·Status: UNKNOWN ·Phase: NA
-
Effect of Neuromuscular Electrical Stimulation Combined With Blood Flow Restriction on Muscular and Cardiovascular Function
NCT03662555 ·Status: UNKNOWN ·Phase: NA