Balloon-Expandable Versus Self-expanding Transcatheter Heart Valve for Treatment of Symptomatic Native Aortic Valve Stenosis (BEST)
NCT05454150 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1960
Last updated 2025-12-04
Summary
Over the last years, several randomized studies comparing transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) have established TAVI as a treatment option in symptomatic patients with aortic stenosis (AS) (1,2,3). Most transcatheter heart valves (THV) available are designed on either a balloon-expandable (BE) or a self-expanding (SE) concept.
Despite major differences, both designs are recommended to be used indifferently in most of the clinical situations and a significant number of centers only implant one of this two THV design. It remains unclear however, whether these 2 very different THV concepts are achieving similar or different clinical outcomes and could be considered a single "Class" of device. While there is an urgent clinical need to clarify this issue in an exponentially growing therapeutic field, to date no large randomized study powered to compare the 2 THV designs on individual endpoints has been conducted or initiated. Recently, two large-scale French registry-based propensity matched analyses, including more than 30,000 patients, have reported a higher 90 days and 1-year mortality with the use of SE as compared to BE-valve (4,5). However, as the propensity-score matching-approach cannot rule out residual confounders, and as some of the most recent THV iterations were not part of the investigation, there is an urgent need to conduct a randomized trial sufficiently powered to compare head-to-head the latest generation of SE and BE-valve on all-cause mortality. In addition, two small randomized studies have recently showed the inferiority of a new SE-valve compared to BE-valve and SE-THV (SCOPE1 trial, J Lanz. Lancet. 2019 Nov 2;394(10209):1619-1628. and SCOPE 2 trial, Circulation in press), thus further questioning wether THV should be considered as a single \"Class\" regardless the THV design.
The objective of the present randomized clinical investigation will be to evaluate the impact of THV design (SE vs BE) on the risk of all-cause mortality at 90 days and 1 year.
The present clinical investigation will the first randomized clinical investigation to compare head to head the benefit of BE-valve over SE-valve on total mortality and /or disabling stroke at 90 days and 1-year using a superiority design. Previous head-to-head studies included only a small number of patients, non-inferiority designs and combined endpoints. This clinical investigation will be the first to generate sufficient evidences to change clinical practice and international guidelines to clarify whether one THV design is superior (or not) to the other one (BE vs SE-valve). The result of the clinical investigation is key for clinicians indicating the treatment and for the patients receiving the treatment
Conditions
- Aortic Valve Stenosis
Interventions
- DEVICE
-
balloon-expandable valve
Sapien 3/Ultra, Edwards Lifesciences©
- DEVICE
-
self-expanding valve
Evolut R/Pro, Medtronic©
Sponsors & Collaborators
-
Ministry of Health, France
collaborator OTHER_GOV -
Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
collaborator OTHER -
University Hospital, Lille
lead OTHER
Principal Investigators
-
Eric Van Belle, MD,PhD · University Hospital, Lille
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-04-19
- Primary Completion
- 2025-10-29
- Completion
- 2035-12-29
Countries
- France
Study Locations
More Related Trials
-
PREVAIL-TF: Transfemoral Placement of Aortic Balloon Expandable Transcatheter Valves Trial (Europe)
NCT00820599 ·Status: COMPLETED ·Phase: NA
-
TAVI Without Balloon Predilatation (of the Aortic Valve ) SAPIEN 3
NCT02729519 ·Status: COMPLETED ·Phase: NA
-
SMall Annuli Randomized To Evolut™ or SAPIEN™ Trial
NCT04722250 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Safety and Efficacy of the Symetis ACURATE Neo/TF Compared to the Edwards SAPIEN 3 Bioprosthesis.
NCT03011346 ·Status: COMPLETED ·Phase: NA
-
ALLIANCE AVIV: Safety and Effectiveness of the SAPIEN X4 Transcatheter Heart Valve in Failing Aortic Bioprosthetic Valves
NCT05172973 ·Status: RECRUITING ·Phase: NA
-
PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - Nested Registry 3/Valve-in-Valve
NCT03225001 ·Status: COMPLETED ·Phase: NA
-
COMPASSION XT PAS - Post-approval Study of the SAPIEN XT THV in Patients With Pulmonary Valve Dysfunction
NCT02987387 ·Status: COMPLETED
-
SOURCE 3: Observational Study to Evaluate Safety and Performance of SAPIEN 3 THV System in Real Life Practice
NCT02698956 ·Status: COMPLETED
-
The SAPIEN 3 Ultra System in Intermediate Risk Patients With Symptomatic, Severe Aortic Stenosis
NCT03471065 ·Status: COMPLETED ·Phase: NA
-
BIOVALVE - I / II Clincial Investigation
NCT02249000 ·Status: COMPLETED ·Phase: NA
-
Safety and Performance Study of the Edwards CENTERA Self-Expanding Transcatheter Heart Valve
NCT01808274 ·Status: COMPLETED ·Phase: NA
-
The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B
NCT02184442 ·Status: COMPLETED ·Phase: NA
-
ACURATE Prime XL Human Feasibility Study
NCT05224245 ·Status: COMPLETED ·Phase: NA
-
Medical & Economical Evaluation of Fenestrated & Branched Stent-grafts to Treat Complex Aortic Aneurysms
NCT01168037 ·Status: COMPLETED
-
Prospective, Multicenter, Randomized Controlled Clinical Study Evaluating the VitaFlow Liberty® Flex Transcatheter Aortic Valve Delivery System for the Treatment of Severe Aortic Stenosis Lesions
NCT07145463 ·Status: RECRUITING ·Phase: NA
-
VitaFlow™ Transcatheter Aortic Valve System Pre-market Trial
NCT04655742 ·Status: UNKNOWN ·Phase: NA
-
Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
NCT01775046 ·Status: COMPLETED
-
Post-Market Surveillance Registry to Monitor Performance and Safety of V8 Device
NCT02099942 ·Status: COMPLETED
-
Smart Angioplasty Research Team-Optimal Strategy for Side Branch Stenting in Coronary Bifurcation Lesion With Drug-Coated Balloon
NCT07019350 ·Status: RECRUITING ·Phase: NA
-
Branched Thoracic Endovascular Grafts for the Treatment of Thoraco-abdominal Aortic
NCT01874197 ·Status: RECRUITING ·Phase: NA
-
PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis
NCT02675114 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Endurant™ Stent Graft System in the Treatment of Infra-renal Abdominal Aortic Aneurysms (ENDURANT France)
NCT01526811 ·Status: COMPLETED
-
PROGRESS: Management of Moderate Aortic Stenosis by Clinical Surveillance or TAVR
NCT04889872 ·Status: RECRUITING ·Phase: NA
-
PREVAIL-TA: Placement of Aortic Balloon Expandable Transcatheter Valves Trial (Europe)
NCT01238835 ·Status: COMPLETED ·Phase: NA
-
Safety and Performance Study of the Edwards SAPIEN 3 Transcatheter Heart Valve/ The SAPIEN 3 Study
NCT01808287 ·Status: COMPLETED ·Phase: NA