Waveform Periodicity Analysis of Complex Fractionated Electrograms in Patients With Persistent Atrial Fibrillation

NCT05426603 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80

Last updated 2022-06-22

No results posted yet for this study

Summary

Atrial fibrillation (AF) has been the most frequently occurring, sustained arrhythmia, which causes significant morbidity and mortality. AF may not always be a totally random process. It can be maintained by stable and rapid reentrant circuits resulting in fibrillary conduction throughout the atria. During mapping of AF, difficulty is frequently encountered during the identification of culprit sites and an analysis of the wave propagation particularly when the electrogram signals demonstrate wide temporal and spatial disparities. Catheter ablation targeting regions with fractionated potentials or high frequencies during AF, has been previously proposed as a treatment strategy. However, the benefit of adjunctive CFAE (complex fractionated atrial electrogram) ablation or linear ablation after successful PVI (pulmonary vein isolation) was controversial based on the recent data from the Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial Part II (STAR AF II) trial. Therefore, the optimal ablation strategy for persistent AF remains undetermined and an alternative approach has to be explored.

Conditions

  • Atrial Fibrillation, Persistent

Interventions

PROCEDURE

Pulmonary vein isolation

The 3D geometry of the LA will be created using CARTO 3 system (version 6) with UDM Module and VISITAG Optimum Device Performance (ODP) module. Continuous circumferential lesions will then be created encircling the right and left PV ostia using a 7.5F, 3.5-mm Thermocool SMARTTOUCH ablation catheter (Biosense Webster, Inc., Diamond Bar, CA, USA).Pentaray catheter will be used and facilitate the high density mapping of atrial substrate (PentarayTM, Biosense Webster Inc., Diamond Bar, CA, USA). The radiofrequency energy will be applied with contact force range 5-25 g continuously with a target Ablation Index target 380-400 on the posterior wall and 550 - 600 on the anterior wall and maximum power of 25-35W in a power control mode

PROCEDURE

Substrate ablation(PRISM based)

Substrate modification will be guided by waveform periodicity analysis. The User Defined Map of waveform periodicity analysis will be also created by CARTO 3 system (version 6) with and VISITAG ODP module. Pentaray catheter will be used and facilitate the high density mapping of atrial substrate (PentarayTM, Biosense Webster Inc., Diamond Bar, CA, USA). Substrate modification based on waveform periodicity analysis will be performed by using a 7.5F, 3.5-mm Thermocool SMARTTOUCH ablation catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). The radiofrequency energy will be applied with contact force range 5-25 g continuously with a target Ablation Index target 380-400 on the posterior wall and 550 - 600 on the anterior wall and maximum power of 25-35W in a power control mode.

Sponsors & Collaborators

  • Buddhist Tzu Chi General Hospital

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
20 Years
Max Age
90 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-02-19
Primary Completion
2022-12-31
Completion
2025-12-21

Countries

  • Taiwan

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05426603 on ClinicalTrials.gov