Pulmonary Function Assessment and Evaluation Using Self-administrable and Portable Electrical Impedance Tomography
NCT05346081 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 125
Last updated 2023-11-18
Summary
Spirometry is the most commonly used modality for measuring lung function. However, spirometry is a coordination-dependent test and may lead to erroneous results if subjects are unable to fully comply with the instructions. It also lacks the capability for regional assessment of pulmonary functions.
Electrical impedance tomography (EIT) is a potential alternative test to spirometry. EIT has been employed in clinical use to provide qualitative and quantitative measurements of ventilation in patients on mechanical ventilators to prevent lung damage or patient-ventilator desynchronies.
In this study, we aim to utilize EIT lung device to study EIT-derived indicators in pulmonary functional assessment and develop novel biomarkers for detecting and monitoring pulmonary diseases. This is a non-interventional clinical study on patients with chronic lung diseases, to establish the feasibility of using EIT-lung device in detecting lung functional changes. Specifically, we will establish the relationship between EIT-derived functional indicators and spirometry results. Furthermore, we will explore, develop, and establish EIT-derived regional lung functional indicators in healthy and chronic diseased states.
Subjects with underlying lung disease, and age- and gender-matched healthy control subjects will be recruited in this study. They will perform spirometry and EIT examination, as well as an interview with a structured questionnaire.
The results from spirometry and EIT test will be correlated and compared to identify the feasibility and accuracy of EIT lung device. Lung function parameters (e.g. FEV1, FVC, and FEV1/FVC ratio) measured using a spirometer would also be calculated from lung flow-volume curves derived from continuous EIT functional images. Regional lung function assessment will also be explored using EIT, and establish regional EIT features that could assist in screening and evaluating different chronic lung diseases. The EIT-derived indicators will be finally analyzed together with demographics, clinical assessments and patient history to derive fine grained insights and elucidate the effect of demographics and biometrics on EIT lung data. The parameters include, but not limited to, age, chest size, gender, weight, height, BMI, smoking habits and ethnicity. The analysis will improve the stability of the EIT indicators, and ultimately increase their predictive power towards diseased lung regions.
With the availability of the EIT device on lung function assessment, which was validated with spirometry findings, patients who are unable to perform spirometry but need a proper lung function assessment can benefit by having the EIT test. These patients include but not limited to those who need major lung resection and interstitial lung diseases on anti-fibrotic. EIT can also be a more comfortable alternative to spirometry for patients who need lung function assessment.
Conditions
- Lung Diseases
Interventions
- DEVICE
-
Electrical impedance tomography
Electrical impedance tomography (EIT) is a potential alternative non-invasive diagnostic screening measure to spirometry.
Sponsors & Collaborators
-
Queen Mary Hospital, Hong Kong
lead OTHER
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-05-01
- Primary Completion
- 2024-12-31
- Completion
- 2025-06-30
Countries
- Hong Kong
Study Locations
More Related Trials
-
Comparison of Lung Function Based on Electrical Impedance Tomography and CT Lung Volume in Patients With Rib Fractures
NCT04946331 ·Status: UNKNOWN ·Phase: NA
-
Stress Echo and Electric Impedance Tomography (EIT) Pilot Study
NCT01168557 ·Status: COMPLETED ·Phase: NA
-
Triple EIT (Electrical Impedance Tomography)
NCT07247474 ·Status: RECRUITING
-
Electrical Impedance Imaging of Patients on Mechanical Ventilation
NCT02232841 ·Status: COMPLETED
-
Monitoring of Regional Lung Ventilation by Chest Electrical Impedance in the Course of Extubation
NCT04180410 ·Status: UNKNOWN ·Phase: NA
-
Human Electrical-Impedance-Tomography Reconstruction Models
NCT02773680 ·Status: UNKNOWN ·Phase: PHASE3
-
Electrical Impedance Imaging Techniques in Guiding the Use of Chest Physiotherapy in Patients with Pneumonia
NCT06642701 ·Status: COMPLETED ·Phase: NA
-
Pleural Effusion Drainage in Mechanically Ventilated Patients Monitored by EIT
NCT03231072 ·Status: COMPLETED ·Phase: NA
-
Lungs Aeration Changes Examined by Impedance Tomography During High Frequency Jet Ventilation.
NCT02997072 ·Status: COMPLETED
-
Non-Invasive Measurements of Changes in Pulmonary Artery Pressure in Intensive Care Unit Patients Using Electrical Impedance Tomography - A Feasibility Study
NCT06544148 ·Status: RECRUITING
-
Evaluation of Electrical Impedance Tomography for the Diagnosis of Chronic Rejection in Lung Transplants Recipients
NCT02863835 ·Status: COMPLETED ·Phase: NA
-
Pulmonary Ventilation After Fiberoptic Bronchoscopy Using EIT
NCT05875662 ·Status: COMPLETED
-
The Clinical Application of EIT in Clinically Ill Patients: a Cross-sectional Study
NCT06954415 ·Status: NOT_YET_RECRUITING
-
The Study of Regional Lung Ventilation-perfusion by EIT
NCT05105932 ·Status: UNKNOWN
-
Pressure Opening With Electrical Impedance Tomography
NCT05825534 ·Status: UNKNOWN ·Phase: NA
-
Electrical Impedance Tomography (EIT) Monitoring in Adults With ALI or ARDS
NCT01272882 ·Status: COMPLETED ·Phase: NA
-
Electric Impedance Tomography Before and After Dilatative Tracheotomy
NCT02161328 ·Status: COMPLETED
-
Effects of Inspiratory vs Expiratory Breath-Hold on Lung Perfusion Measured by EIT Saline Indicator Method: A Self-Controlled Study
NCT07303972 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Study on Ventilation Distribution With Electrical Impedance Tomography for Paediatric Respiratory Failure
NCT05347563 ·Status: RECRUITING
-
Blood Loss Measurement Using Electrical Impedance Tomography
NCT05287334 ·Status: UNKNOWN ·Phase: NA
-
Weaning From Mechanical Ventilation Guide by Assessment of Lung Tidal Distribution With EIT
NCT03118804 ·Status: COMPLETED
-
Electrical Impedance Tomography in Evaluating the Effects of Noninvasive Ventilation in Post-Operative Cardiac Surgery
NCT03371628 ·Status: UNKNOWN ·Phase: NA
-
Lung Volume Change Between Noninvasive Positive Pressure Ventilation by Nasal Pillow and High Flow Nasal Cannula
NCT02292992 ·Status: UNKNOWN ·Phase: NA
-
Genesis Electrical Impedance Tomography (EIT): A Preliminary Study
NCT03797183 ·Status: RECRUITING
-
Physiological Behavior of Respiratory Maneuvers
NCT03270826 ·Status: COMPLETED