Belgian Study to Assess the Efficacy and Safety of the RESTORER Iliac Stent for Treatment of Aorto-iliac Lesions.
NCT05293002 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 131
Last updated 2024-10-16
Summary
The BARISTA study tests the safety and efficacy of the Restorer stent from the company iVascular. This stent is a medical device that is already approved for use in Europe, to treat stenotic (narrowed) iliac arteries. 200 Belgian patients from 13 different hospitals will be included in this study. Patients will be medically monitored for 2 years from the day of the study procedure. The treatment of the stenotic iliac arteries will be according to the standard of care, using the Restorer stent. This endovascular treatment consists of introducing the necessary materials in the blood vessels by a puncture in the groin under general or local anaesthesia, after which a thin plastic tube will be inserted into the femoral artery through the puncture site, until the stenotic iliac artery is reached. Medical imaging is done by angiography. The stenotic/occluded section of the artery will first be dilated by inserting and inflating a balloon. Next, the Restorer stent will be placed and, if necessary, another balloon may be inserted and inflated to allow the stent to fit nicely to the vessel wall and optimise the result. As per standard of care, follow-up will be done in the hospital after 1, 6, 12, and 24 months. During these visits, an ultrasound scan of the treated artery will be taken to evaluate the patency of the blood vessel. Also, two short questionnaires will be completed asking about the quality of life and walking difficulties. The use of medication will be recorded. If adverse events are experienced, they will be reported.
Conditions
- Peripheral Arterial Disease
Interventions
- DEVICE
-
Restorer Iliac Stent System
Not applicable (only one intervention)
Sponsors & Collaborators
-
ID3 Medical
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-06-13
- Primary Completion
- 2025-07-31
- Completion
- 2025-12-31
Countries
- Belgium
Study Locations
More Related Trials
-
Misago Iliac Study
NCT01016275 ·Status: COMPLETED
-
A Prospective Single-Arm Multicenter StuDy of the BarE TEmporary SPur StEnt System foR the tREatment of Vascular Lesions Located in the infrapoplitEal Arteries beLow the Knee (DEEPER REVEAL)
NCT05358353 ·Status: COMPLETED ·Phase: NA
-
A Prospective Study of the Bard® LifeStent® Solo Vascular Stent System
NCT02262949 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Express LD to Treat Stenosed or Occlusive Atherosclerotic Disease in Iliac Arteries
NCT00352222 ·Status: COMPLETED ·Phase: PHASE3
-
Safety and Performance of the Zeus CC Stent for the Treatment of Iliac Occlusive Disease
NCT01499329 ·Status: UNKNOWN
-
Endovascular Treatment of Atherosclerotic Lesions in the SFA Using the Sinus-superflex-635 Stent
NCT01816854 ·Status: COMPLETED
-
CONTINuous Infra-Inguinal Stenting Using the Bard® LifeStent® VascUlar Stent SysteMs ("CONTINUUM")
NCT00908947 ·Status: TERMINATED ·Phase: NA
-
An Observational Study to Evaluate Safety, Performance, and Clinical Benefit of BeFlow
NCT07010354 ·Status: RECRUITING
-
Bard® LifeStent® Vascular Stent Delivery System Study
NCT01179984 ·Status: COMPLETED ·Phase: NA
-
PRESERVE-Zenith® Branch Endovascular Graft-Iliac Bifurcation Clinical Study
NCT02571907 ·Status: COMPLETED ·Phase: NA
-
A Prospective, Multi-center, Single Arm Study Evaluating the Express™ Renal Premounted Stent System in the Treatment of Atherosclerotic Lesions in the Aortorenal Ostium.
NCT00597142 ·Status: COMPLETED ·Phase: PHASE4
-
Genomics of In-Stent Restenosis
NCT00341562 ·Status: COMPLETED
-
PRESERVE-Zenith® Branch Endovascular Graft-Iliac Bifurcation
NCT02475798 ·Status: NO_LONGER_AVAILABLE
-
An Investigator Initiated Trial to Evaluate the Safety and Feasibility of the DyNETIC-35 Stent for Iliac Lesions Via a Trans-radial Approach
NCT05372952 ·Status: COMPLETED
-
Belgian Prospective Multicentre Registry to Evaluate Safety and Performance of the Optimed Stent in the Superficial Femoral Artery
NCT01499342 ·Status: COMPLETED
-
Assessment of GORE® EXCLUDER® IBE Plus Stent Graft Performance in Patients Undergoing Endovascular Iliac Revascularization
NCT07304102 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Observational Study to Evaluate the BioMimics 3D Stent System: MIMICS-3D
NCT02900924 ·Status: COMPLETED
-
PERVIDEO I Registry, The Lutonix Paclitaxel-Coated Balloon Catheter for the Treatment of Coronary In-Stent Restenosis
NCT00916279 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Evaluation of the Sinus-Venous Stent for the Treatment of Iliofemoral Venous Occlusive Disease
NCT02799914 ·Status: WITHDRAWN
-
A Prospective Study of the Performance of the Bard® LifeStent® Vascular Stent Systems (REALITY)
NCT01920308 ·Status: COMPLETED
-
BOLT Lithotripsy RESTORE BTK Trial
NCT05535907 ·Status: COMPLETED ·Phase: NA
-
Post-market Registry in Patients With Iliac Aneurysm Undergoing Endovascular Stenting With the E-liac Stent Graft System
NCT02209194 ·Status: COMPLETED
-
Prospective, Non-randomized Multi-center, Controlled Physician-initiated Trial: Rotarex Belgium In-stent Occlusion
NCT02212626 ·Status: COMPLETED ·Phase: PHASE4
-
The Complete® Self-Expanding Stent and Stent Delivery System Registry
NCT00730730 ·Status: COMPLETED ·Phase: NA
-
VISIBILITY™ Iliac Study
NCT01402700 ·Status: COMPLETED ·Phase: NA