XEN45 in the Treatment of Chinese Patients With Primary Open-angle Glaucoma
NCT05130554 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2021-11-23
Summary
Glaucoma is the second most common blindness disease in the world, second only to cataracts. The current treatment of glaucoma is mainly to reduce intraocular pressure.At present, two commonly used surgical methods are trabeculectomy and implantation of drainage valve. These methods are superior to drug treatment in reducing intraocular pressure, but the effect duration of these two methods is not long, and there may be serious complications and failure.
Compared with traditional glaucoma surgery, MIGS may have better safety.The XEN45 gel implant is a collagen tube with a length of 6 mm and a diameter of 45 µm, which creates a new channel for drainage of aqueous humor by connecting the anterior chamber and the subconjunctival space. The implant is composed of porcine gelatin cross-linked with glutaraldehyde, and has good biocompatibility and tolerance. Therefore, after the advent of XEN45 products, more and more studies have shown that this treatment has excellent safety and effectiveness in reducing intraocular pressure in patients with open-angle glaucoma.
Considering that the XEN45 gel stent has been in the market for a relatively short time, we conducted this prospective study to investigate the effect of XEN45 surgery in the treatment of primary open-angle glaucoma, in order to support ophthalmologists in formulating the best surgical plan for patients. The promotion of this surgical method.
Conditions
- Glaucoma
- Glaucoma, Open-Angle
- Surgery
Interventions
- PROCEDURE
-
XEN45 gel stent implantation
The XEN45 gel implant is a collagen tube with a length of 6 mm and a diameter of 45 µm, which creates a new channel for drainage of aqueous humor by connecting the anterior chamber and the subconjunctival space. The implant is composed of porcine gelatin cross-linked with glutaraldehyde, and has good biocompatibility and tolerance.This treatment method has excellent safety and effectiveness in reducing the intraocular pressure of patients with open-angle glaucoma. At the same time, the operation is simple and safe.
Sponsors & Collaborators
-
Allergan
collaborator INDUSTRY -
Zhongshan Ophthalmic Center, Sun Yat-sen University
lead OTHER
Principal Investigators
-
Mingkai Lin, M.D,Ph.D · Zhognshan Ophthalmic Center, Sun Yat-sen University
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-11-07
- Primary Completion
- 2022-06-30
- Completion
- 2022-09-30
Countries
- China
Study Locations
More Related Trials
-
XEN-45 Gel Stent Versus Trabeculectomy in Glaucoma: Gold-Standard Pathway Study (GPS)
NCT03654885 ·Status: COMPLETED ·Phase: PHASE4
-
A Trial of China Laser and Surgery Study Glaucoma in Rural China
NCT02955849 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Evaluate the Efficacy and Safety of Glaucoma Implant in Primary Open Angle Glaucoma
NCT05892185 ·Status: UNKNOWN ·Phase: NA
-
Prophylactic Peripheral Iridectomy Prevents Aphakic Angle-closure Glaucoma
NCT03610295 ·Status: COMPLETED ·Phase: NA
-
Real World Evidence of Xen45 Gel Implant in Pseudoexfoliation Glaucoma
NCT06993311 ·Status: COMPLETED
-
Direct Selective Laser Trabeculoplasty in Ethnic Chinese Population
NCT05902871 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Study to Assess Adverse Events and Effectiveness of Gel Stent (XEN63) Implantation Using Ab Interno and Ab Externo Approaches in Adult Participants With Glaucoma
NCT06822738 ·Status: RECRUITING ·Phase: PHASE3
-
Evaluation of the XEN Implant in Moderate Primary Open Angle Glaucoma (POAG) Participants
NCT02006693 ·Status: COMPLETED ·Phase: PHASE4
-
Satisfaction With XEN Gel Stent Versus Trabeculectomy for the Treatment of Glaucoma
NCT03852810 ·Status: COMPLETED
-
Changes in Corneal Endothelial Cell Density After Transscleral ab Interno Glaucoma Gel Stent Implantation
NCT04547036 ·Status: COMPLETED
-
Longitudinal Study on Glaucoma Surgery Using XEN® Gel Stent
NCT03151577 ·Status: UNKNOWN ·Phase: NA
-
Artificial Intelligence-assissted Glaucoma Evaluation
NCT03268031 ·Status: COMPLETED
-
Study on Intraocular Structural Parameters and Surgical Effect Before and After the Onset of Malignant Glaucoma
NCT04220879 ·Status: UNKNOWN
-
Ahmed Glaucoma Valve Surgery With Mitomycin-C
NCT02805257 ·Status: COMPLETED ·Phase: PHASE2
-
A Prospective Evaluation of Open-Angle Glaucoma Subjects on Two Topical Hypotensive Medications Treated With One Suprachoroidal Stent
NCT01252914 ·Status: COMPLETED ·Phase: PHASE4
-
Analysis of Conjunctival Changes as Indicators for Ab-interno Gelatin Microstent Implantation Surgery Outcomes
NCT04727411 ·Status: COMPLETED ·Phase: NA
-
Trabecular Microbypass IStent in Patients with Glaucoma
NCT06630546 ·Status: COMPLETED ·Phase: NA
-
OculusGen™ Collagen Matrix Implant for Phaco-Trabeculectomy in Primary Glaucoma: a Case-Control Study
NCT01027247 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical Efficacy and Safety of Minimally Invasive Glaucoma Surgery on Primary Angle Closure Glaucoma
NCT02964676 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Phacogoniotomy in Medically-controlled POAG
NCT06201455 ·Status: RECRUITING ·Phase: NA
-
UCP Glaucoma Treatment for Primary Glaucoma in China
NCT04145830 ·Status: COMPLETED ·Phase: NA
-
The Effectiveness of YAG Iridotomy in Preventing Peripheral Anterior Synechia After CLASS in Primary Open Angle Glaucoma
NCT04912362 ·Status: UNKNOWN ·Phase: NA
-
Efficacy Evaluation and Influencing Factors of Argon Laser Peripheral Iridoplasty in Acute Angle Closure Glaucoma
NCT04912310 ·Status: UNKNOWN ·Phase: NA
-
One, Two, or Three iStents for the Reduction of Intraocular Pressure in Open-angle Glaucoma Subjects
NCT01517477 ·Status: COMPLETED ·Phase: NA
-
Deep Sclerectomy vs Xen in Solo Procedure
NCT05201378 ·Status: COMPLETED