Comparison of Clinical Efficacy Between Dynamic Dip Screw and Cannulated Compression Screw for Fresh Femoral Neck Fracture

NCT04959370 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 91

Last updated 2021-07-13

No results posted yet for this study

Summary

For fresh femoral neck fracture internal fixation, both DHS and CCS can make strong fixation of hip and have good recovery. There is no statistical difference in complications after surgery between the two procedures. Patients with DHS internal fixation have earlier postoperative weight bearing, which is conducive to functional exercise of the injured limb. DHS internal fixation system is recommended for patients with unstable fractures and severe osteoporosis.

Conditions

  • Femoral Neck Fractures

Interventions

DEVICE

internal fixation implantation of dynamic hip screw

Dynamic hip screws (DHS) are a femoral head-sparing orthopedic device used to treat femoral neck fractures.

DEVICE

internal fixation implantation of cannulated compression screw

Cannulated Screw is designed to provide a minimally invasive method of anatomical fixation.

Sponsors & Collaborators

  • Peking University Third Hospital

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
20 Years
Max Age
65 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-01-31
Primary Completion
2016-06-30
Completion
2018-09-30
FDA Device
Yes

Countries

  • China

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.