Application of 3D-Matrix in Knee Joint Sports Injury
NCT04957043 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 150
Last updated 2021-07-12
Summary
3 d scan sequence can realize continuous thin layer scanning, the thinnest layer thickness of 0.5 mm, to reduce the effects of partial volume effect and improve the spatial resolution image, the other 3 d sequence can according to need to multiplanar reconstruction based on the original image, the image of the watch is no longer limited to a fixed plane, and can avoid repeated scanning, reducing overall inspection time. Initially, 3D MRI uses gradient echo sequences (3D-GRE). Although the scan time of 3D-GRE is acceptable and has a high spatial resolution, the contrast between tissues is poor. In recent years, is voxel 3D fast spin-echo sequence (3D-FSE) has become an alternative 3D scanning sequence. Compared with the 3D-GRE sequence, 3D-FSE has better-intertissued contrast. However, there are still some problems in the application of 3D sequence in clinical practice. On the one hand, although 3D sequence reduces the overall scanning time, it increases the single scanning time, so it is easy to produce motion artifacts. On the other hand, although many studies have demonstrated the diagnostic efficacy of 3D sequences in the diagnosis of common intraarticular structural injuries, especially in the diagnosis of knee cartilage injuries, the diagnostic value of 3D sequences is comparable to that of conventional 2D-FSE sequences, but the evidence on whether 3D sequences can replace 2D sequences is still insufficient.
Recently, a new fast signal acquisition technology -- Compressed Sensing (Compressed Sensing) technology has been gradually applied to many kinds of MRI sequences, and its application in 3D sequences can greatly shorten the single scan time. In this study, Modulated Flip Angle Technique in Refocused Imaging with Extended Echo was applied by United Imaging Co., Ltd. (Compressed Sensing) Train, 3D-Matrix), which is a fast self-selected echo sequence based on variable turn Angle technology, and its single scan time can be shortened to 5 minutes. 3 d sequence to more systematic evaluation on sports injury of knee joint application value, the investigators will study from within the bony structure of knee joint injury, joint structure damage and injury of the surrounding support structure aspects to discuss the diagnosis effect, and with arthroscopy for the gold standard to evaluate the accuracy of the 3 d structure within the sequence in the diagnosis of knee joint injury.
Conditions
- MRI
Sponsors & Collaborators
-
Peking University Third Hospital
lead OTHER
Principal Investigators
-
huishu yuan · Peking University Third Hospital
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-03-01
- Primary Completion
- 2018-07-01
- Completion
- 2019-06-01
Countries
- China
Study Locations
More Related Trials
-
Contrast-free Magnetic Resonance Angiography (MRA) at 3.0 T for Intracranial Aneurysm Detection
NCT01031147 ·Status: UNKNOWN
-
Research on Acetabular Labrum Injury Based on MR: Multi-angle Deep Learning Model
NCT04950036 ·Status: COMPLETED
-
Assessing Brain Injury Using Portable Magnetic Resonance Imaging (MRI)
NCT05469139 ·Status: COMPLETED
-
Proving Utility of a New Field-cycling MRI Prototype in Acute Stroke Patients
NCT07004140 ·Status: RECRUITING
-
Quantitative T1rho Magnetic Resonance Imaging in Healthy Subjects
NCT04993196 ·Status: RECRUITING ·Phase: NA
-
Imaging Location of Hamstring Muscle Lesions in Sport and Relationships With Injury Mechanism.
NCT03373084 ·Status: TERMINATED
-
Comparison of the Application in Traumatic Brain Edema Between EIT and Non-invasive ICP Monitoring
NCT02027857 ·Status: UNKNOWN ·Phase: NA
-
Optimization of Sequences to Improve the Quality and Comfort of the Magnetic Resonance Imaging Examination
NCT05326581 ·Status: RECRUITING
-
Improvement of Knowledge About the Arthrogenic Muscle Inhibition in the Aftermath of Knee Trauma.
NCT03950024 ·Status: COMPLETED ·Phase: NA
-
Brain Diseases on 7.0T Magnetic Resonance Imaging
NCT05287750 ·Status: RECRUITING ·Phase: NA
-
Optimal Low B-value in Intravoxel Incoherent Motion Diffusion-weighted MR Imaging of the Brain
NCT02411864 ·Status: COMPLETED
-
Brain MRI for Knee OA
NCT05986513 ·Status: UNKNOWN ·Phase: NA
-
EEG Motor Movement and Imagery Dataset for Stroke
NCT05499442 ·Status: UNKNOWN
-
Monitoring of Brain Metabolites Using Proton and Deuterium MR Techniques
NCT06705010 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Advanced MRI Applications for Mild Traumatic Brain Injury
NCT02070588 ·Status: TERMINATED ·Phase: NA
-
Deep Enhanced Imaging in Stroke and Vascular Neurology
NCT05614193 ·Status: RECRUITING
-
New Topographic Classification of Knee Bone Marrow Lesions
NCT03976141 ·Status: COMPLETED
-
Feasibility Testing of 7-Tesla Magnetic Resonance Imaging
NCT05992298 ·Status: RECRUITING ·Phase: NA
-
MRI Diffusion Tensor Tractography to Monitor Peripheral Nerve Recovery After Severe Crush or Cut/Repair Nerve Injury
NCT02960516 ·Status: COMPLETED
-
[18F]NIDF PET Imaging in Tau-related Diseases
NCT07306598 ·Status: RECRUITING
-
Estimating Brain Biomechanics Using MRI
NCT01633268 ·Status: COMPLETED
-
3D MRI Assessment of Femoroacetabular Impingement in Patients With ACL Rupture - Exploratory Study
NCT07271277 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Évaluation de l'Impact du Compressed Sensing Sur le Signal QSM
NCT04907487 ·Status: COMPLETED
-
Can Diffusion Tensor Imaging (DTI) of the Optic Ways Contributes to Predict the 6 Months Prognosis of Optic Neuritis (ON)?
NCT03570385 ·Status: COMPLETED ·Phase: NA
-
Neuroimaging and End Stage Renal Disease
NCT03961724 ·Status: UNKNOWN