Pilot Study Evaluating the Optimization of the ORBEYE Blue Light Filter During Fluorescence-Guided Resection of Gliomas

NCT04937244 · Status: UNKNOWN · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 10

Last updated 2021-06-23

No results posted yet for this study

Summary

Fluorescence-guided resection using 5-ALA induced tumor fluorescence of malignant gliomas allows for better identification of tumor tissue and more radical resection in select patients and improvements in progression-free and overall survival. With new developments in surgical microscopy, the development of digital exoscopes have provided advanced visualization as well as improvements in ergonomics and accessibility of the surgical field. The use of the exoscope in 5-ALA fluorescence-guided tumor surgery has the potential to enhance the ability of the surgeon to remove brain tumors with high efficacy. While algorithms for use of 5-ALA fluorescence have been optimized for use with traditional microscopes, the use of fluorescence techniques in newer digital exoscopes have not been developed. The primary outcome of the study is to obtain parameters to optimize visualization of fluorescence intensity and perform optimization based on the intensities achieved. The operating ORBEYE exoscope will be fitted with a blue light filter. All experiments will be performed in darkened operating rooms. The ORBEYE exoscope will be set up at constant distances from the target and incident light intensities. The focal distance and light intensity settings will be recorded from the data displayed on the microscope. Patients (experimental group) will receive 5ALA treatment before operation, blue light filter imagining will take place after tacking up dura and prior to direct resection. The expected outcomes of image analysis will be to have a set of exoscope parameters optimized for visualization of 5ALA tissue in different tumor types. This 5ALA characterization of visualization parameters has never been completed on an exoscope. Optimizing ORBEYE exoscope parameters will define a standard in glioma resection using 5ALA under a novel exoscopic filter as well as contribute insight into the use of the fluorescent filter for additional tumor types.

Conditions

  • Malignant Glioma of Brain

Interventions

DIAGNOSTIC_TEST

5ALA exoscopic fluorescence filter

Visualization of tumor tissue with 5ALA will be done in the operating room to localize neoplastic tissue. The operation will be conducted in a standard fashion uninfluenced by the imaging on the ORBEYE exoscope. The ORBEYE exoscope will be used with the blue light filter after tacking up dura upon first visualization of tumor tissue prior to direct resection. Images will be taken prior to, during and at the end of the planned resection. The ORBEYE exoscope will be set up at constant distances from the target and incident light intensities. The focal distance and light intensity settings will be recorded from the data displayed on the microscope. The ORBEYE exoscope or standard operating microscope (depending on surgeon preference) will then be used in the standard fashion of an operative microscope with a fluorescent filter, to assist with surgical resection as per the surgeon's preference. Resection will proceed according to current standard of care.

Sponsors & Collaborators

  • Olympus Corporation

    collaborator INDUSTRY
  • Northwell Health

    lead OTHER

Study Design

Allocation
NA
Purpose
DEVICE_FEASIBILITY
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-05-13
Primary Completion
2022-05-11
Completion
2022-05-11
FDA Drug
Yes
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials