Patient Satisfaction and Visual Function Following Implantation of Trifocals or Extended Range of Vision Intraocular Lenses
NCT04900662 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 480
Last updated 2022-02-04
Summary
Cataract surgery is a fast evolving refractive procedure, which aims to restore vision. The majority of intraocular lens (IOL) implants following cataract surgery are monofocal IOLs, which have been designed to improve distance vision by replacing the lens diopter power with a single focal point. Monofocal IOLs have been associated with very few complications related to the material or the technology. However, after the surgery patients are spectacle dependent for near and intermediate tasks. This, in turn, has decreased the patient's post-operative satisfaction and quality of life. Multifocal intraocular lenses (IOLs) were introduced into the market in the 1980s. This type of IOLs provides clear distance and near vision, which affects the quality of life and visual expectations of the patients who receive them. Studies have indicated higher levels of patient's satisfaction with regards to distance and near vision after the implantation of multifocal lenses. With Multifocal IOLs; however, patients are still spectacle dependent for intermediate tasks such as computer work. The recent development of trifocal IOLs has been found to provide optimal near, intermediate, and distance visual performances; decrease spectacle dependence; and increase patient satisfaction.AcrySof®IQ PanOptix™ (PanOptix) was introduced into the market in 2015 with a design that allows the IOL to provide optimal near, intermediate, and distance visual performances; decrease spectacle dependence; and increase patient satisfaction. Despite the benefits of corrected visual acuity at multiple distances, multifocal and/or trifocal IOLs are associated with certain disadvantages, including contrast sensitivity loss, dysphotopsia, halos and glare, which account for over a third of the justifications used for IOL model replacement. Dysphotopsia is the result of light reflecting off the intraocular lens (IOL) onto the retina which causes a variety of visual symptoms that are expressed in a positive or a negative form. Positive dysphotopsia refers to bright artifacts that are noticed in only certain lighting conditions, such as glare and halos. Negative dysphotopsia refers to the formation of a barrier, which prevents light from reaching the retina. The result of the negative form of dysphotopsia is the formation of shadows that are often in the temporal visual field. In 2014, the extended range of vision TECNIS Symfony®IOL (Symfony), with new optical technology using a proprietary achromatic diffractive echelette design, received a CE Mark. However, it was not until 2016 that this IOL became the first extended depth of focus (EDF) IOL to gain approval by the U.S. Food and Drug Administration. This new optical technology corrects the corneal chromatic aberration for enhanced contrast sensitivity, generating a continuous vision for distance through intermediate into near with low incidence of halos and glare. Despite the benefits of EDF IOLs, Monaco et al. conducted a study in Italy and indicated that both PanOptix and Symfony IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the PanOptix IOL may be better for patients with near-vision requirements. A few studies in the literature have evaluated the performance of the PanOptix and Symfony IOLs in Europe. Our current study would add great value to the literature since to the best of our knowledge; this is the first study to address the same IOLs in North America. Cataract surgery expectations are continuously rising, and in an effort to maximize patient satisfaction post-operatively, the appropriateness of a patient for a particular IOL implantation should be evaluated carefully during the pre-operative assessment. Therefore, further research is warranted to evaluate patient satisfaction with both PanOptix and Symfony IOLs. The purpose of this study is to compare the visual outcomes and the subjective satisfaction results between patients implanted with PanOptix and Symfony IOLs.
Conditions
- Cataract
Sponsors & Collaborators
-
University of Toronto
collaborator OTHER -
Queen's University
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-07-05
- Primary Completion
- 2021-08-31
- Completion
- 2023-12-31
Countries
- Canada
Study Locations
More Related Trials
-
Visual Outcomes of Functional Intraocular Lenses in Cataracts
NCT06092164 ·Status: NOT_YET_RECRUITING
-
Bilateral Monofocal Versus Monofocal-EDOF IOL Implantation: Quality of Vision Comparison
NCT06002399 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Outcomes of Bilateral Implantation of an Enhanced Monofocal Intraocular Lens
NCT06118944 ·Status: COMPLETED ·Phase: NA
-
Monovision vs Multifocal Lens Insertion in Cataract Patients
NCT01998698 ·Status: COMPLETED ·Phase: NA
-
Visual Function of Enhanced Monofocal Intraocular Lenses
NCT07262021 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Visual Function and Patient Satisfaction After Bilateral Implantation of AcrySof Natural ReSTOR (Model SN60D3) or AcrySof Natural Monofocal (Model SN60AT)
NCT00759668 ·Status: COMPLETED ·Phase: NA
-
Multifocals and Accommodating/Bilateral Implantation of Different Multifocal Intraocular Lens (IOLs)
NCT00934960 ·Status: TERMINATED
-
Multifocal vs Monofocal IOL in Congenital Cataract Surgery
NCT04872829 ·Status: COMPLETED
-
Comparing Monofocal IOLs in Highly Myopic Cataract Patients
NCT06905938 ·Status: NOT_YET_RECRUITING
-
Visual Performance of Functional Intraocular Lenses in Cataracts
NCT05581888 ·Status: UNKNOWN ·Phase: NA
-
Prospective Clinical Study of Unilateral or Bilateral Implantation of Intraocular Lens in Cataract Patients
NCT04265820 ·Status: UNKNOWN ·Phase: NA
-
Toric Intraocular Lens (IOL) Implantation for Management of Cataracts
NCT05797298 ·Status: RECRUITING
-
Trifocal Diffractive Intraocular Lens After Cataract Extraction With Phacoemulsification
NCT04465279 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
The PanOptix Trifocal IOL: A Study of Patient Satisfaction, Visual Disturbances, and Uncorrected Visual Performance
NCT04146961 ·Status: COMPLETED
-
Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
NCT04655274 ·Status: COMPLETED
-
Visual Performance After RESTOR Implantation
NCT01065064 ·Status: COMPLETED ·Phase: PHASE4
-
Visual Performance of an Extended Depth of Focus IOL in an Emmetropic or Monovision Modality
NCT06624826 ·Status: RECRUITING ·Phase: NA
-
Surgical Outcomes After Routine Cataract Extraction & Implantation of a Conventional or Spheric Intraocular Lens
NCT00366496 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Aspheric Toric Intraocular Lens (IOL) Implantation Versus Aspheric Non-Toric Lens Implantation
NCT01225926 ·Status: COMPLETED ·Phase: NA
-
Implantation of a Trifocal Hydrophobic IOL in Patients That Underwent Refractive Surgery
NCT04054427 ·Status: WITHDRAWN ·Phase: NA
-
Clinical Comparison of a Monofocal eDOF IOL With a Monofocal IOL
NCT04631068 ·Status: COMPLETED ·Phase: NA
-
Evaluation Of Deep Anterior Lamellar Keratoplasty By Anterior Segment Ocular Coherence Tomography
NCT05345652 ·Status: UNKNOWN
-
Neural Compensation, Visual Function and Visual Quality After Monofocal or Multifocal Intraocular Lens Implantation
NCT02644720 ·Status: UNKNOWN ·Phase: NA
-
PMCF Study of Preloaded Trifocal IOL
NCT04884178 ·Status: COMPLETED ·Phase: NA
-
Clinical Investigation of the Multifocal IOL POD F GF in Cataracteous Eyes
NCT04699266 ·Status: COMPLETED ·Phase: NA