Pilot Testing for Midline Measuring Device
NCT04883060 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2024-01-30
Summary
Identifying the exact middling on the patient's head during the planning phase of surgery is crucial yet can be challenged by patient's head position and hair. The investigators have invented a device that uses anatomical landmark to quickly and gracefully identify the midline on a patient's head. The device is a U-shaped instrument equipped with a laser pointer at the midline. The instrument also has smooth spheres that can be positioned over the patients' ears bilaterally. The midline laser pointer will identify the midline on the patients' head. this measurement procedure is typically done after the patient is placed under anesthesia. The standard way of determining the midline on the skull is simply by surgeon's vision without any measurements. This new technique will be contrasted against the standard way. The device was invented by investigators in neurosurgery (led by Dr. Matthew Howard III). This is not patented it at this time. There is no company involved in manufacturing (assembly was completed with the help of the hospital's machine shop).
Conditions
- Ventriculo-Peritoneal Shunt Infection
Interventions
- DEVICE
-
midline localizer
a midline localizer device with a laser pointer is used to localize where the midline is likely to be located on the patient head prior to the surgery.
Sponsors & Collaborators
-
University of Iowa
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-01-01
- Primary Completion
- 2019-07-01
- Completion
- 2019-07-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Optical Detection of Intravenous Infiltration
NCT01126710 ·Status: COMPLETED
-
Performance Thresholds Evaluation by Wet Injection Quantification and Magnetic Resonance Imaging (MRI) of Subcutaneous and Intramuscular Injections (0,65ml) of Several Configurations of Needle-free Devices (ZENEO®)
NCT03044301 ·Status: COMPLETED ·Phase: NA
-
Assessment of the Precision of the Sherlock 3CG Tip Positioning System
NCT01275430 ·Status: TERMINATED ·Phase: NA
-
Confirming Feeding Tube Position Using CORTRAK
NCT04601571 ·Status: WITHDRAWN ·Phase: NA
-
Human Research Program Flight Thigh Cuff
NCT06476106 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Instrument Precision Study for Validation of Philips Dx
NCT02699970 ·Status: COMPLETED
-
Pilot Study to Assess the Use of Spy Elite for Assessment of Amputation Healing
NCT02440295 ·Status: COMPLETED
-
Product Evaluation of a Newly Developed Intermittent Catheter.
NCT02966015 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Safety and Efficacy of Single-use Precision Filtered Infusion Sets for Intravenous Infusion
NCT04962516 ·Status: COMPLETED
-
Effectiveness of ActiSight™ Needle Guidance System in Patients Undergoing CT-Guided Procedures
NCT01148706 ·Status: COMPLETED ·Phase: PHASE4
-
DyeVert Pilot Trial
NCT02606734 ·Status: COMPLETED ·Phase: NA
-
Controlled Acute Hypoxia Study - Abbreviated Sensor Line
NCT02216344 ·Status: COMPLETED
-
Testing the Efficacy and Safety of the WEI Nasal Jet
NCT02005406 ·Status: COMPLETED
-
Data Collection in Patients Undergoing CT-Guided Needle Interventions for NeedleWays System Development
NCT02329665 ·Status: UNKNOWN ·Phase: NA
-
Evaluation by Magnetic Resonance Imaging of Intramuscular Injections Performance in Thigh With 2 Configurations of the Needle-free Injector ZENEO®.
NCT05967013 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Zynex Blood Volume Monitor in Healthy Adult Volunteers During a Blood Draw
NCT01834612 ·Status: COMPLETED ·Phase: PHASE1
-
Sensor Off Study Using a Nellcor USB Pulse Oximetry Monitor Interface Cable
NCT02265783 ·Status: COMPLETED ·Phase: NA
-
Minimally-Invasive Realtime Assessment of Continuous Lactate in Exercise
NCT04238611 ·Status: UNKNOWN ·Phase: NA
-
Research on the Localization Accuracy of PICC Guided by EDUG in Real World
NCT03230357 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of the Zynex Blood Volume Monitor (CM-1500) in Healthy Male Adult Subjects During a Blood Draw
NCT01646060 ·Status: COMPLETED ·Phase: PHASE1
-
Prospective Use of Philips iSuite for Interventional Procedures
NCT03432936 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Effectiveness and Safety of CT-guided Needle Placement in the Liver With the Aid of the ActiSight Needle Guidance System
NCT01367392 ·Status: COMPLETED ·Phase: PHASE4
-
Novel Cervical Retraction Device
NCT02283463 ·Status: UNKNOWN ·Phase: NA
-
Prospective Clinical Evaluation of BD NRFit™ Devices and Accessories.
NCT05953363 ·Status: COMPLETED
-
Autonomous Blood Drawing Optimization and Performance Testing
NCT05878483 ·Status: RECRUITING ·Phase: NA