Diagnostic Validation of Wearable ECG Monitoring Patch, ATP-C120
NCT04857268 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 320
Last updated 2021-04-26
Summary
A new wearable patch-type device, ATP-C120 (ATsens, Seongnam, Korea) is a novel, single-lead ECG monitoring device and can continuously monitor the ECG signal for upto 11 days. This study is designed to experiment its diagnostic capability of new-onset atrial fibrillation in high risk patients. Several studies reported that validated CHA2DS2-VASc score has high performance in predicting new-onset atrial fibrillation and there are over 10 percent of new-onset atrial fibrillation in patients whose calculated CHA2DS2-VASc scores are ≥ 2. Thus, through this study, the investigators sought to evaluate the validation of early detection of new-onset atrial fibrillation by ATP-C120.
Conditions
- Atrial Fibrillation New Onset
Interventions
- DEVICE
-
wearable continuous ECG monitoring patch, ATP-C120
ATP-C120 is a novel, single-lead ECG monitoring device which can continuously monitor the ECG signal as long as 14 days (11 days if the device is connected to the smartphone via Bluetooth) when attached to skin adjacent to the heart of patients. It weighs about 8.3 g, with a size of 84 × 39 × 8.3 mm. When the device is attached to the patient, several predefined methods were utilized to prevent the occurrence of noise or signal loss. First, the skin was cleansed and disinfected using a 70% ethanol solution. Skin hair was removed if needed. Then the protection film was removed from the patient-side surface of the device. The device is placed at the left 3rd intercostal space 45 degrees tilted toward the inside.
Sponsors & Collaborators
-
Kyungpook National University Hospital
collaborator OTHER -
Seoul National University Bundang Hospital
lead OTHER
Principal Investigators
-
Chang-Hwan Yoon, MD.,Ph.D. · Seoul National University Bundang Hospital
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 19 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-11-13
- Primary Completion
- 2022-12-31
- Completion
- 2023-12-31
Countries
- South Korea
Study Locations
More Related Trials
-
Study Watch Atrial Fibrillation (AF) Detection Investigation
NCT04074434 ·Status: COMPLETED
-
Performance of Masimo INVSENSOR00057 in Detecting Atrial Fibrillation (Afib)
NCT05472012 ·Status: COMPLETED ·Phase: NA
-
Atrial Fibrillation Detected by Continuous ECG Monitoring
NCT02036450 ·Status: COMPLETED ·Phase: NA
-
CONVERGE Post-Approval Study (PAS)
NCT05393180 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Watchman FLX Left Atrial Appendage Closure Device Post Approval Study ( Europe Only)
NCT02654470 ·Status: COMPLETED
-
Evaluation of the Effectiveness and Safety of Remote Electrocardiographic Monitoring in Patients with Atrial Fibrillation Following Ablation Therapy
NCT06751459 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Enhanced Diagnostics for Early Detection of Atrial Fibrillation
NCT02270112 ·Status: COMPLETED
-
Comparison of Anticoagulation With Left Atrial Appendage Closure After AF Ablation
NCT03795298 ·Status: COMPLETED ·Phase: NA
-
CONVERGE - Epi/Endo Ablation For Treatment of Persistent Atrial Fibrillation(AF)
NCT01984346 ·Status: COMPLETED ·Phase: NA
-
VitalConnect VitalPatch ECG Interpretation/Arrhythmia Detection
NCT04202718 ·Status: WITHDRAWN ·Phase: NA
-
Prediction and Maintenance of Sinus Rhythm Among Atrial Fibrillation Patients
NCT04313296 ·Status: TERMINATED ·Phase: NA
-
Investigational Device Evaluation of the WATCHMAN FLX™ LAA Closure Technology
NCT02702271 ·Status: COMPLETED ·Phase: NA
-
AF Ablation Based on High Density Voltage Mapping and CFAE
NCT03046043 ·Status: COMPLETED ·Phase: NA
-
Impedance vs. Contact Force Guided Atrial Fibrillation Ablation Using Automated Annotation System
NCT02364401 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of CT Guided Ablation of Cardiac Ganglionated Plexi
NCT04642976 ·Status: COMPLETED
-
Safety and Efficacy Study of Amniotic Membrane Patch to Treat Postoperative Atrial Fibrillation
NCT02193321 ·Status: WITHDRAWN ·Phase: PHASE1/PHASE2
-
EnSite™ HD Grid Catheter AF/AT Mapping Study
NCT02656537 ·Status: COMPLETED ·Phase: NA
-
Left Atrial Appendage Closure Compared to Standard Antiplatelet Therapy in Patients With AF Who Underwent PCI
NCT02492230 ·Status: UNKNOWN ·Phase: PHASE2
-
Clinical Performance of AFGen1
NCT06076798 ·Status: COMPLETED
-
Single Center Pilot Study Using the ECGenius System to Collect Electrogram Data to Test an Ablation Impact Algorithm
NCT05458648 ·Status: COMPLETED
-
Safety and Efficacy Study of The Combined Ablation Procedure To Treat Longstanding Persistent Atrial Fibrillation
NCT01103661 ·Status: TERMINATED ·Phase: NA
-
Observe the Safety and Effectiveness of the WATCHMAN FLX™ for Subjects in Hong Kong
NCT04096963 ·Status: COMPLETED
-
High-Density (HD) Wave Mapping in Subjects With Atrial Fibrillation as a Predictor of Recurrence After a Single Ablation Procedure Using a PVI-Only Strategy
NCT03882021 ·Status: COMPLETED ·Phase: NA
-
DURABLE-I Study: Dielectric Unravelling of Radiofrequency ABLation Effectiveness
NCT02878213 ·Status: COMPLETED ·Phase: NA
-
Tulane iPredict, Prevent Study to Evaluate the Progression of Atrial Myopathy.
NCT04703166 ·Status: RECRUITING