NerveTrend vs. i-IONM in Prevention of Recurrent Laryngeal Nerve Events During Bilateral Thyroid Surgery.
NCT04794257 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 264
Last updated 2021-05-04
Summary
The aim of this study is to compare two distinct modes of NIM Vital application in thyroid surgery: i-IONM vs. NerveTrend mode with respect to prevalence of early postoperative RLN injury.
The hypothesis explored in this study is that NerveTrend mode may be more accurate than conventional i-IONM mode in intraoperative identification of impending neural injury and in prognostication of postoperative glottis function in monitored bilateral thyroid surgery. Hence, NerveTrend mode may be considered a bridge between i-IONM and c-IONM modes, and particularly in health care environments with limited financial resources it can be considered a substantial step forward representing a modern alternative to the c-IONM technique and providing benefits over conventional i-IONM mode.
A prospective, randomized study with 2 arms: i-IONM vs. NeveTrend mode (n=132 patients and 264 nerves at risk, each).
The primary outcome measure is prevalence of recurrent laryngeal nerve (RLN) injury (%) on postoperative day 1 assessed by direct laryngoscopy.
Conditions
- Thyroid Diseases
- Surgery
- Recurrent Laryngeal Nerve Injuries
Interventions
- DEVICE
-
Neuromonitoring of the recurrent laryngeal nerves
The NIM Vital system (Medtronic, Jacksonville, US) operates with surface electrodes integrated with an endotracheal NIM TriVantage tube 7.0-8.0 in diameter, which is inserted by an anesthetist between the vocal folds under direct vision during intubation. The standardized technique of IONM RLNs wll be used, including initial vagal response evaluation at the beginning and final vagal response evaluation at the end of surgery (IONM = L1+V1+R1+R2+V2+L2) according to the recommendations formulated by the International Intraoperative Neural Monitoring Study Group. The nerves will be stimulated using a monopolar electrode and the interrupted stimulation technique at 1mA, 100ms impulse duration and 4Hz frequency. In case of the bifurcated RLN nerves, the assessment includes post-stimulation response of each nerve branch. Adduction of the vocal folds is detected by the endotracheal tube electromyography and abduction by finger palpation of muscle contraction in the posterior cricoarytenoid.
Sponsors & Collaborators
-
Marcin Barczynski
lead OTHER
Principal Investigators
-
Marcin Barczynski · Department of Endocrine Surgery, Jagiellonian University College of Medicine
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-04-01
- Primary Completion
- 2022-12-31
- Completion
- 2023-03-31
Countries
- Poland
Study Locations
More Related Trials
-
Comparison of Intr-operative Neuromonitoring Technique in Trans-oral Endoscopic Thyroidectomy Vestibular Approach
NCT06801444 ·Status: RECRUITING
-
Low-dose Rocuronium Effect Neural Monitoring in Thyroid Surgery
NCT04230915 ·Status: UNKNOWN ·Phase: NA
-
Different Types of Electrostimulation Probes During IONM
NCT03460912 ·Status: COMPLETED
-
Trial on Intraoperative Neuromonitoring (IONM) in Thyroid Cancer Surgery.
NCT04842994 ·Status: UNKNOWN ·Phase: NA
-
Feasibility of Neostigmine for Intraoperative Neuromonitoring in Thyroid Surgery
NCT04873531 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Intraoperative Neuromonitoring of External Branch of Superior Laryngeal Nerve in Thyroid Surgery
NCT06002984 ·Status: RECRUITING ·Phase: NA
-
Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve Versus Neurostimulation
NCT01163045 ·Status: COMPLETED ·Phase: PHASE2
-
Intra Operative Continuous Laryngeal Nerve Monitoring During Thyroid Surgery and Interpretation of the Post-operative Voice Quality in Relation to the Electromyography Data Obtained During Surgery
NCT01413802 ·Status: COMPLETED ·Phase: NA
-
Lidocaine Reduces Muscle Tremor is Beneficial for Intraoperative Recurrent Laryngeal Nerve Monitoring
NCT03530033 ·Status: UNKNOWN ·Phase: NA
-
Effectiveness of Intraoperative Neuromonitoring of External Branch of Superior Laryngeal Nerve During Thyroid Surgery
NCT03773120 ·Status: TERMINATED ·Phase: NA
-
Predisection Risk Factors for Vocal Cord Palsy After Total Thyroid Surgery
NCT04986592 ·Status: COMPLETED
-
Neuromuscular Block Monitoring During Monitored Thyroidectomy
NCT04982185 ·Status: COMPLETED
-
Innervation of Human Cricopharyngeal Muscle By Recurrent Laryngeal and External Branch of Superior Laryngeal Nerve
NCT02761239 ·Status: COMPLETED ·Phase: NA
-
Neural Monitoring of the Superior Laryngeal Nerve in Thyroid Surgery
NCT02395146 ·Status: COMPLETED ·Phase: NA
-
New Intraoperative Nerve Monitoring Device
NCT07071571 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
CRANIO-CAUDAL AND LATERAL APPROACH FOR RECURRENT LARYNGEAL NERVE
NCT04379804 ·Status: COMPLETED ·Phase: NA
-
Effect of Intraoperative Nerve Monitoring on Voice Quality During Thyroid Surgery
NCT02509715 ·Status: UNKNOWN ·Phase: NA
-
Effect of Reversed Tracking Method for Identification of EBSLN in Thyroid Surgery
NCT03680222 ·Status: UNKNOWN ·Phase: NA
-
Effect of IONM on Efficacy and Safety Using Sugammadex in Thyroid Surgery
NCT03634956 ·Status: UNKNOWN ·Phase: NA
-
Intraoperative Neuromuscular Monitoring and Its Impact on Pre- and Postoperative Acoustic Outcomes in Thyroid Surgery
NCT06254859 ·Status: RECRUITING
-
Near Infrared Spectroscopy in Thyroidectomy
NCT04186715 ·Status: COMPLETED
-
Intra-operative Steroid Irrigation for Reducing Recurrent Laryngeal Nerve Palsy Post-thyroidectomy
NCT07068048 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Post Thyroidectomy Echographic Method for Study of Vocal Fold Motion
NCT03976011 ·Status: UNKNOWN ·Phase: NA
-
Effect of Cervical Block on Recurrent Laryngeal Nerve Monitoring During Thyroid Surgery
NCT04585126 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Transcutaneous Electrical Nerve Stimulation on Posterior Neck Pain After Thyroidectomy