HoloStream Study - Video Capture Device Usage
NCT04774588 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2021-03-01
Summary
Objectives:
Primary
* Evaluate the primary operator usability of VSI streaming software for realtime streaming of images from video capture devices to a head mounted display (Hololens 2) during Interventional Radiology procedures Secondary
* Evaluate Radiographer usability of VSI streaming software.
* Develop suggestions for future research studies to assess the safety and efficacy of the VSI streamer software during other Interventional radiology procedures
* Evaluate the impact of VSI streaming software on room setup time, procedural time and fluoroscopy time
* Assess the feasability of remote collaboration by real time image transmission between remote devices through 3D telemedicine
Conditions
- Nephrostomy; Complications
- Fistula
- Central Venous Catheter Thrombosis
Interventions
- OTHER
-
VSI streamer and Microsoft Hololens 2 classed as a Class III device by Health Canada.
1.1 Description of VSI streamer device and software The VSI Streamer is a box that can be connected to ultrasound, endoscope, microscope, laparoscope and other devices via HDMI connection. The view of the imaging devices, which is conventionally displayed on a monitor, is transmitted wirelessly and in real time to the Mixed Reality HoloLens 2 (Microsoft Inc.) and appears as a virtual monitor that can be flexibly moved and positioned in space. Since this is Mixed Reality, the real environment remains visible. If required, several virtual monitors can be streamed into the Mixed Reality glasses at the same time
Sponsors & Collaborators
-
University of Calgary
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 99 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-03-01
- Primary Completion
- 2022-04-01
- Completion
- 2022-04-01
More Related Trials
-
Electroencephalograph for Detection of Acute Ischemic Stroke
NCT01737723 ·Status: UNKNOWN
-
Indocyanine Green Fluorescence Uptake in Human Carotid Artery Plaque
NCT01873716 ·Status: COMPLETED ·Phase: PHASE1
-
Remote Ischemic Conditioning With Novel Optical Sensor Feedback Device in Acute Ischemic Stroke
NCT05408130 ·Status: COMPLETED ·Phase: NA
-
Impact of Aspiration Thrombectomy During Carotid Stenting
NCT01550835 ·Status: UNKNOWN ·Phase: NA
-
Head COOLing in IscHemic Stroke Patients Undergoing EndovAscular Thrombectomy: a Feasibility and Safety StuDy
NCT06335641 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Formation of Health Professionals Through in Situ Simulation to Improve Performances During the Initial Step of Thrombectomy for Ischemic Strokes
NCT03738371 ·Status: UNKNOWN
-
Detection of Area of Ischemia in Patients With Subacute Stroke Via a Hybrid EEG-fNIRS Brain-computer Interface
NCT03034902 ·Status: TERMINATED ·Phase: NA
-
Prospective Evaluation of Carotid Free-floating Thrombus
NCT02405845 ·Status: COMPLETED ·Phase: NA
-
Measuring Collaterals With Multi-phase CT Angiography in Patients With Ischemic Stroke
NCT02184936 ·Status: COMPLETED
-
A Volumetric Coiling in Aneurysm Registry of the Penumbra Coil 400TM System
NCT01754051 ·Status: COMPLETED
-
The Purpose of This Study is to Determine Whether CerebroFlo™ EVD Catheter is Effective During the Treatment of Intraventricular Hemorrhage (IVH)
NCT05113381 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study of the Treatment of Acute Ischemic Stroke Using the NOVIS Transcarotid Neuroprotection System
NCT04881162 ·Status: TERMINATED ·Phase: NA
-
Micro-embolic Signals Detection With Transcranial HOLter in Acute Ischemic STroke
NCT02762552 ·Status: COMPLETED ·Phase: NA
-
Optimizing Acute Ischemic Stroke Diagnostics Using Artificial Intelligence
NCT05652933 ·Status: RECRUITING
-
Aneurysm Study of Pipeline in an Observational Registry
NCT01557036 ·Status: TERMINATED
-
Visio-conference for Pre-hospital Triage of Stroke Suspicions
NCT04042584 ·Status: COMPLETED ·Phase: NA
-
A Study of the Use of the Q Aspiration Catheter to Remove Clot in Stroke Patients
NCT04089917 ·Status: COMPLETED
-
Early Postprocedural Susceptibility-Weighted Imaging and Vessel-Wall Imaging For Prediction of Complications After Flow-Diversion Treatment
NCT05716360 ·Status: UNKNOWN
-
Medical Imaging Screening for Posterior-circulation Ischemic Stroke
NCT06094569 ·Status: RECRUITING
-
SONOlysis in Prevention of Brain InfaRctions During Internal Carotid Endarterectomy
NCT02398734 ·Status: COMPLETED ·Phase: NA
-
FIrst-Pass Reperfusion With the NeVa Stent-Retriever Trial
NCT04072367 ·Status: WITHDRAWN ·Phase: NA
-
Trenza Embolization Device for Intrasaccular Aneurysm Treatment
NCT04380350 ·Status: COMPLETED
-
"Spot Sign" Selection of Intracerebral Hemorrhage to Guide Hemostatic Therapy
NCT01359202 ·Status: COMPLETED ·Phase: PHASE2
-
Acute Stroke Thrombectomy: Does CT Perfusion Accurately Predict Infarct on MRI After Recanalization
NCT02988492 ·Status: COMPLETED ·Phase: NA
-
Pivotal Study of the FRED Stent System in the Treatment of Intracranial Aneurysms
NCT01801007 ·Status: COMPLETED ·Phase: NA