Effect of Artificial Tears on the Parameters of the Eye and Its Impact on IOL Power Calculation for Cataract Surgery
NCT04706455 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2021-01-12
Summary
First, preoperative biometry of the eye at the IOL Master® will be performed. Then, corneal topography will be measured at the Oculus pentacam®. Afterwards, one of two eye drops are instilled in the eye, and biometry and corneal topography will be repeated after 5 minutes.
For all patients, the Barrett Universal II formula will be used for calculation of IOL power. Predicted refraction outcome will be referred to as SEQ. The chief surgeon will perform the uneventful standard cataract operation with in-the-bag implantation of a HOYA IOL (Model 251) through a 2.4-mm corneal incision.
A Subjective Refraction using plus principle will be performed one month after the operation, and ETDRS visual acuity charts will be used to measure best-corrected visual acuity. Refraction will be described as SR (postoperative SEQ) and will be calculated as:
SR = sphere + (0.5\*cylinder)
Conditions
- Cataract Senile
- Dry Eye
Interventions
- DEVICE
-
sodium hyaluronate 0.1%
Instillation of one drop sodium hyaluronate 0.1%
- DEVICE
-
sodium hyaluronate 0.3%
Instillation of one drop sodium hyaluronate 0.3%
Sponsors & Collaborators
-
Second Affiliated Hospital of Xi'an Jiaotong University
lead OTHER
Principal Investigators
-
Ling Bai, MD,PhD · Second Affiliated Hospital of Xi'an Jiaotong University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 30 Years
- Max Age
- 95 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-12-01
- Primary Completion
- 2021-02-28
- Completion
- 2021-03-31
Countries
- China
Study Locations
More Related Trials
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Multifocal-toric IOL Compared to Multifocal IOL Combined With Limbal Relaxing Incisions for Correction of Moderate Astigmatism During Cataract Surgery
NCT06277349 ·Status: COMPLETED ·Phase: NA
-
A Comparison of the Accuracy of Toric Intraocular Lens Formulas
NCT04776603 ·Status: COMPLETED
-
Prospective Study of Deep Anterior Lamellar Keratoplasty Using Acellular Porcine Cornea
NCT03105466 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of an Ocular Bandage Contact Lens for the Treatment of Dry Eye After Complicated and Combined Cataract Surgery
NCT04120389 ·Status: UNKNOWN ·Phase: NA
-
Retrospective Clinical Investigation of the Safety and Performance of 640PM Trifocal IOL Implantation in Patients With Cataract and/or Ametropia (Hyperopia, Myopia) and/or Presbyopia
NCT05735990 ·Status: COMPLETED
-
Intraocular Lens Power Calculation for Combined Phaco-vitrectomy Procedures
NCT03856346 ·Status: UNKNOWN
-
Pseudoaccommodation of the Light Adjustable Lens: A Comparitive Study
NCT07176429 ·Status: ENROLLING_BY_INVITATION
-
Evaluation of the Eyhance and Zoe Lenses
NCT06665659 ·Status: NOT_YET_RECRUITING
-
The Application of Lens Dysfunction Index (DLI) in the Timing of Age-related Cataract Surgery
NCT04711395 ·Status: UNKNOWN
-
Clinical Evaluation of a New Aspheric Intraocular Lens.
NCT00786565 ·Status: COMPLETED ·Phase: PHASE4
-
Multi-center Ocular Biological Parameters Study
NCT04340635 ·Status: UNKNOWN
-
A Intra-patient Comparison of Closed Loop and Plate Haptic Toric Intraocular Lenses
NCT02264457 ·Status: UNKNOWN ·Phase: PHASE4
-
IOL Power Calculation Using Dual Schiempflug Analyzer
NCT02362334 ·Status: UNKNOWN
-
Evaluation of Toric Intraocular Lens(IOL) Combined With Capsular Tension Ring(CTR) in Patients With Cataract Combined With High Myopia
NCT06571773 ·Status: ACTIVE_NOT_RECRUITING
-
Refractive Outcomes Utilizing Two SS-OCT Biometers for IOL Power Calculations
NCT06801678 ·Status: RECRUITING
-
Intraocular Lens (IOL) Calculation Improvement
NCT01372657 ·Status: TERMINATED
-
Comparing Monofocal IOLs in Highly Myopic Cataract Patients
NCT06905938 ·Status: NOT_YET_RECRUITING
-
Accuracy of the Pentacam and IOL Master to Calculate the Effective Corneal Power After Corneal Refractive Surgery
NCT00466908 ·Status: WITHDRAWN
-
Retrospective, Non-interventional Clinical Investigation of the Safety and Performance of 640AD Monofocal Intraocular Lens
NCT06578910 ·Status: COMPLETED
-
Surgical Outcomes After Routine Cataract Extraction & Implantation of a Conventional or Spheric Intraocular Lens
NCT00366496 ·Status: COMPLETED ·Phase: NA
-
Predictive Performance of a Generative Model for Corneal Tomography After ICL Implantation
NCT07146737 ·Status: RECRUITING
-
Visual Quality Change of Eyes Implanted With Diffractive Multifocal Intraocular Lens After Cataract Surgery
NCT02234635 ·Status: UNKNOWN ·Phase: NA
-
Study on the Application of Intraoperative Optical Coherence Tomography Technique in the Diagnosis and Treatment of Lens Diseases
NCT06687356 ·Status: RECRUITING ·Phase: NA
-
Visual Outcomes of an Enhanced Monofocal Intraocular Lens Targeted for Monovision in Highly Myopic Eyes: a Randomized Controlled Trial
NCT07168109 ·Status: NOT_YET_RECRUITING ·Phase: NA