Comparisons of gaIt aNalyses pERformance Between the Gaitrite walkwaYs
NCT04557592 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 98
Last updated 2020-09-21
Summary
The GAITRite® system is an instrumented with resistive pressure sensors gait analyzer. It was first validate in 2001 against paper-and-pencil (intraclass correlation coefficient \[ICC\] \> 95%) for spatial measures and against video-based (ICC \> 93%) for temporal measures, and was thus a reliable tools to measure step lengths and times in both walkway center and left-of-center measurements. It was considered as one of the gold standards in gait analyses. This gait analyze system may distinguish prospectively faller and non-faller older adults, but it can detect spatial, temporal, and spatiotemporal measures of gait and greater variability of gait parameters which were associated with and predictive of both global- and domain-specific cognitive decline. Moreover, spatiotemporal gait parameters analyzed using GAITRite® were more disturbed in the advanced stages of dementia, and more affected in the non-AD dementia than in AD suggesting that quantitative gait parameters could be used as a surrogate marker for improving the diagnosis of dementia.
Nevertheless, GAITRite® is not a unique system and it comprises different walkways. One of these technologies was a roll-up system (platinum plus classic, RE, Basic and Safari), and the other was a system composed by a changeable association of plates (CIRFACE). In order to ensure a good comparability between studies using these different walkways, it appears important to compare the performances of these walkways in gait analysis. Thus, the main aim of this study was to compare the performances in gait analyze between the GAITRite® platinum plus classic and the GAITRite® CIRFACE among older adults. Secondary aims were to compare these parameters among patients with cognitive complaint, minor or major neurocognitive disorder (NCD) related to Alzheimer disease.
Conditions
- Gait Apraxia
- Alzheimer Disease
- Impaired Cognition
Sponsors & Collaborators
-
University Hospital, Angers
lead OTHER_GOV
Eligibility
- Min Age
- 74 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-06-17
- Primary Completion
- 2020-02-26
- Completion
- 2020-02-26
Countries
- France
Study Locations
More Related Trials
-
The Reliability of a Wearable Inertial System in Healthy Adults.
NCT04310982 ·Status: COMPLETED
-
Opti Gait Wearable Gait Tracker
NCT07158580 ·Status: NOT_YET_RECRUITING
-
Evaluation of a Novel Gait Training Device to Support Body Weight
NCT03171207 ·Status: UNKNOWN ·Phase: NA
-
Gait Disorders in Patients With Cognitive Decline
NCT03399591 ·Status: UNKNOWN
-
Interlaboratory Reliability of 3D Gait Analysis
NCT05530213 ·Status: UNKNOWN ·Phase: NA
-
Analyzing Gait Pattern Using Insole-type Gait Analyzer in Patient With Gait Disturbance
NCT06442982 ·Status: RECRUITING ·Phase: NA
-
Evaluation of the Validity of the Ceriter Stride One in Measuring Gait and Pressure Parameters in Healthy Adults
NCT06164652 ·Status: COMPLETED ·Phase: NA
-
At-Home Gait Assessment
NCT05724901 ·Status: COMPLETED
-
Validity of a Belt Mounted Accelerometer to Assess Walking Measures in Patients With Chronic Stroke
NCT04288960 ·Status: SUSPENDED
-
Assessment of a Portable Digital Device for Quantified Analysis of Markerless Walking in Volunteers With Neuromuscular Diseases or Asymptomatic Volunteers
NCT07321977 ·Status: RECRUITING ·Phase: NA
-
Gait, cOgnitiOn & Decline (GOOD)
NCT02350270 ·Status: UNKNOWN
-
Effects of Gait Retraining With Auditory Feedback
NCT04302961 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Common and Specific Information From Neuroimaging and Smartphone
NCT05482906 ·Status: RECRUITING
-
Gait as Predictor of Dementia and Falls. The Gait and Brain Cohort Study
NCT03020381 ·Status: RECRUITING
-
Identify Subjects at Risk for Falling Using Acceleration Based Gait Analysis System
NCT00765297 ·Status: UNKNOWN ·Phase: EARLY_PHASE1
-
Role of Gait Analysis in Different Type of Dementia
NCT06713070 ·Status: NOT_YET_RECRUITING
-
Quantifying Gait Alteration in Multiple Sclerosis Using a Wearable Device
NCT04969848 ·Status: COMPLETED
-
Comparison of Dual Assignment, Cadence, and Gait Speed in Alzheimer's Dementia and Healthy Geriatric Individuals
NCT05767580 ·Status: UNKNOWN
-
Clinical Use of Andante SmartStep System in Gait Rehabilitation
NCT00268658 ·Status: UNKNOWN ·Phase: NA
-
Accelerometers' Validity in Counting Number of Steps in the Elderly Subjects Before Discharge From Rehabilitation Units
NCT03703011 ·Status: COMPLETED ·Phase: NA
-
Gait and Posture Analysis in Hemiparetic Patients Through Optoelectronic Systems, "Smart" Tools and Clinical Evaluation
NCT05801874 ·Status: UNKNOWN
-
Reference Gait Data for Healthy Subjects
NCT03278535 ·Status: COMPLETED
-
Development of Camera Based Gait Quality Measure for Persons With Multiple Sclerosis
NCT06516458 ·Status: RECRUITING
-
Training and Testing Database for IMU Based Gait Analysis Methods
NCT07236008 ·Status: NOT_YET_RECRUITING
-
Validating Wireless Gait Sensor for Elderly Fall Risk Classification
NCT06398431 ·Status: COMPLETED ·Phase: NA