Personalised Risk scOre For Implantation of Defibrillators in Patients With Preserved LVEF>35% and a High Risk for Sudden Cardiac Death
NCT04540289 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2023-03-08
Summary
The objective of the study is to demonstrate that in post-MI patients with preserved LVEF\>35% but high risk for SCD according to a personalised risk score, the implantation of an ICD (index group) is superior to optimal medical therapy (control group) with respect to all-cause mortality.
Conditions
Interventions
- DRUG
-
Optimal Medical Therapy (OMT)
Patients will be treated according to Optimal Medical Therapy defined by the following guidelines: 1. 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes 2. 2016 ESC guidelines for the management of acute and chronic heart failure
- DEVICE
-
Implantable cardioverter-defibrillator (ICD)
An ICD consists of an electronic medical device and electrode leads. The surgery can be performed in local anaesthesia, but a short general anaesthesia is required if the ICD has to be tested giving the patient an electric shock. Besides the possibility to shock during arrhythmias the ICD can potentially terminate ventricular tachycardias by rapid pacing for short periods (small bursts of pacing). The subcutaneous defibrillator is an established and valid alternative to the conventional ICD for the preven-tion of SCD. According to current guidelines, the subcutaneous defibrillator should be considered as an alternative to transvenous defibrillators in patients with an indication for an ICD when pacing therapy for bradycardia support, cardiac resynchronisation or antitachycardia pacing is not needed.
Sponsors & Collaborators
-
Helios Health Institute GmbH
lead OTHER
Principal Investigators
-
Gerhard Hindricks, MD · Department of Electrophysiology, Leipzig Heart Center at University of Leipzig
-
Nikolaos Dagres, MD · Department of Electrophysiology, Leipzig Heart Center at University of Leipzig
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-02-01
- Primary Completion
- 2023-01-31
- Completion
- 2023-01-31
More Related Trials
-
Reduction of Inappropriate Shocks of Implantable Cardioverter Defibrillators (ICDs) With Enhanced SVT Discriminators
NCT01963286 ·Status: COMPLETED ·Phase: NA
-
Implantable Cardioverter Defibrillators - Improving Risk Stratification
NCT01944514 ·Status: COMPLETED
-
Efficacy of Implantable Cardioverter Defibrillator in Patients With Non-ischemic Systolic Heart Failure on Mortality
NCT00541268 ·Status: COMPLETED ·Phase: NA
-
Prospective Observational Study of the ICD in Sudden Cardiac Death Prevention
NCT00733590 ·Status: RECRUITING
-
A PRospective, rAndomizEd Comparison of subcuTaneOous and tRansvenous ImplANtable Cardioverter Defibrillator Therapy
NCT01296022 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Novel Biomarkers to Improve Risk Stratification and Patient Selection in Implantable Cardioverter-defibrillator (ICD) Therapy
NCT01594073 ·Status: COMPLETED
-
Improve Sudden Cardiac Arrest Study
NCT02099721 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Implantable Defibrillator Therapy After a Myocardial Infarction
NCT00673842 ·Status: COMPLETED ·Phase: PHASE3
-
Survival of Patients With Primary Prophylactic ICD Indication
NCT00619593 ·Status: COMPLETED ·Phase: PHASE4
-
Re-evaluation of Optimal Re-synchronisation Therapy in Patients With Chronic Heart Failure
NCT03494933 ·Status: TERMINATED ·Phase: NA
-
NIPS to Identify High-risk Patients With ICD
NCT02373306 ·Status: COMPLETED ·Phase: NA
-
Acute Defibrillation Study
NCT02227121 ·Status: TERMINATED ·Phase: NA
-
Next Generation INCEPTA Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT-D) Field Following Study
NCT01227785 ·Status: COMPLETED
-
Antiarrhythmics Versus Implantable Defibrillators (AVID)
NCT00000531 ·Status: COMPLETED ·Phase: PHASE3
-
Further Acute Research of a Subcutaneous Implantable Defibrillator (S-ICD) System
NCT00399217 ·Status: COMPLETED
-
Decision Support for Adults Facing Implantable Cardioverter-Defibrillator Pulse Generator Replacement
NCT02668900 ·Status: COMPLETED ·Phase: NA
-
Improving the Criteria for Selecting Patients for Primary Prevention of Sudden Cardiac Death by Arrhythmic Risk Stratification
NCT05539898 ·Status: UNKNOWN ·Phase: NA
-
Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)
NCT00000609 ·Status: COMPLETED ·Phase: PHASE3
-
NORDIC ICD (Cardioverter Defibrillator Implantation) Trial
NCT01282918 ·Status: COMPLETED ·Phase: NA
-
Assessment of Appropriate ICD Implantation for Primary Prevention of Sudden Cardiac Death
NCT00926159 ·Status: COMPLETED
-
Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator (ICD) Implantation to Prevent Tachyarrhythmias Following Acute Myocardial Infarction (PROTECT-ICD)
NCT03588286 ·Status: RECRUITING ·Phase: NA
-
Assessment of Risk Factors for Appropriate ICD (Implantable Cardioverter-defibrillator) Intervention in Patients With Ischemic Cardiomyopathy
NCT04014946 ·Status: COMPLETED ·Phase: NA
-
SMS: Substrate Modification Study in Patients Getting an Implantable Cardioverter Defibrillator (ICD)
NCT00170287 ·Status: COMPLETED ·Phase: PHASE4
-
Trop-Shock DFT-testing Versus None
NCT01230086 ·Status: COMPLETED ·Phase: PHASE4
-
T-ICD vs S-ICD Shocks: Myocardial Injuries
NCT03458065 ·Status: UNKNOWN