Lipiflow vs iLux Patient Acceptance and Comfort Study
NCT04454983 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 43
Last updated 2020-08-19
Summary
This study was designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices (Lipiflow vs, iLux). Primary Objective was to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective was to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure. Both devices are exempt from IDE regulations \[21 CFR 812.2(c)\].
Conditions
- Meibomian Gland Dysfunction
- Dry Eye
Interventions
- DEVICE
-
Lipiflow Thermal Pulsation System
The LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents.
- DEVICE
-
iLux System
The iLux™ System is used to apply localized heat and pressure to a patient's eyelids. The system consists of a handheld instrument coupled to a single-use, sterile disposable component that is positioned to bridge the eyelid. The iLux device allows view of the eyelid through a magnifier, then warms the eyelid to 40 to 42˚C, then force-limited compression is applied manually to express the melted meibum from obstructed glands. Warming is accomplished using light energy emitted from LEDs in the Instrument. The LEDs are located behind a clear window on the open end of the Shroud. Two wavelengths of light are used: lime-green (568 nm) and near-infrared (850 nm). A mechanism in the Instrument allows the operator to apply pressure to the eyelid by controlling the movement of the Outer Pad using finger pressure applied to the Compression Control button. The force applied to the Compression Control is measured by a sensor in this mechanism.
Sponsors & Collaborators
-
Johnson & Johnson Vision Care, Inc.
collaborator INDUSTRY -
Epstein, Arthur B., OD, FAAO
lead INDIV
Principal Investigators
-
Arthur B Epstein, OD · Ophthalmic Research Consultants of Arizona
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-01-11
- Primary Completion
- 2020-02-29
- Completion
- 2020-02-29
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Clinical Evaluation of a Silicone Hydrogel Lens
NCT01016132 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study Comparing the Comfort of Three Commercially Available Contact Lenses
NCT02298400 ·Status: WITHDRAWN ·Phase: NA
-
Clinical Evaluation of Two Monthly Replacement Silicone Hydrogel Contact Lenses
NCT01629693 ·Status: COMPLETED ·Phase: NA
-
Clinical Performance of 59% Hioxifilcon A vs. Marketed Hydrogel Contact Lenses in Habitual Hydrogel Wearers
NCT04986644 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Delefilcon A and Senofilcon A Daily Disposable Toric Soft Contact Lenses Over One Week of Wear
NCT06749496 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Comfort in Subjects With Moderate Dry Eye Disease
NCT04830956 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Daytime Corneal Swelling During Wear of Galyfilcon A Lenses
NCT01482819 ·Status: COMPLETED ·Phase: NA
-
Acute Comfort and Blur Profile of a Lubricant Eye Drop Versus a Marketed Eye Ointment
NCT01076998 ·Status: COMPLETED ·Phase: NA
-
Evaluating Visual Acuity and Initial Fit Performance of Two Soft Contact Lenses
NCT04954833 ·Status: COMPLETED
-
Clinical Study of Approved and Investigational Contact Lenses
NCT02708524 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Approved Contact Lenses
NCT07174596 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Visual Performance of Two Types of Cosmetic Contact Lenses
NCT04534764 ·Status: COMPLETED ·Phase: NA
-
A Study to Evaluate the Safety and Efficacy of a New Silicone Hydrogel Contact Lens Design
NCT01449526 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Stenfilcon A Soft Contact Lens When Compared to Ocufilcon B Soft Contact Lens
NCT01354223 ·Status: COMPLETED ·Phase: NA
-
Clinical Comparison of 4 Daily Disposable Soft Contact Lenses
NCT03349632 ·Status: COMPLETED ·Phase: NA
-
Acute Comfort and Blur Profile of a Lubricant Eye Drop Versus a Marketed Lubricant Eye Gel
NCT01077011 ·Status: COMPLETED ·Phase: NA
-
A Study to Evaluate Concomitant Perfluorohexyloctane Use With Contact Lens Wear
NCT07054606 ·Status: COMPLETED ·Phase: PHASE4
-
Acute Comfort and Blurring Profile Evaluation of Marketed Lubricant Eye Drops
NCT00756093 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Comfilcon A and Senofilcon A Lenses
NCT01695369 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Comfort for Two Marketed Daily Disposable Contact Lenses
NCT04968925 ·Status: COMPLETED ·Phase: NA
-
Clinical Performance Evaluation of Two Frequent Replacement Silicone Hydrogel Toric Contact Lenses
NCT05959200 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Comfort of Ocular Lubricants in Symptomatic Contact Lens Wearers
NCT05741216 ·Status: COMPLETED ·Phase: NA
-
Clinical Comparison of Two Daily Disposable Toric Soft Contact Lenses
NCT05483127 ·Status: COMPLETED ·Phase: NA
-
Multi-center Clinical Evaluation of PC 1-Day vs 1-Day Acuvue Moist
NCT02024698 ·Status: COMPLETED ·Phase: NA
-
An Investigation of the Impact of Localized Topical Anesthesia of the Ocular Surface on End-of-day Contact Lens Discomfort
NCT03733899 ·Status: COMPLETED ·Phase: NA