Summary

Fluoroscopy is integral part of diagnostic and therapeutic cardiac procedures. Among medical personnel, interventional cardiologists have the highest per head per year exposure to ionizing radiation which is two to three times greater than the radiologists. Although the patients' exposure is well below the level associated with increased cancer risk, yet as mentioned above, any exposure can be harmful and must be minimized using all possible dose reduction methods under the principle of 'As Low as Reasonably Achievable' (ALARA).

Radiation exposure is influenced by factors that are dependent on patient (weight, body habitus), procedure (access site, procedure complexity, use of protective shielding, collimation) and equipment (overall quality control, field of view, beam filters thickness, pulse rate etc.). In fact in modern fluoroscopic equipment, several settings are customizable to aid reduce total emitted X-ray dose. In a diverse coronary lab as Tabba Heart institute, in addition to training the lab staff on reducing radiation exposure and use of protective gear, employment of a modern X ray system Like Toshiba (Infinix i8000V, Toshiba America Medical Systems, Inc.); equipped with customizable radiation dose reduction technologies and DTS, provides the interventionists an essential tools to ensure the highest radiation safety standards. Data is still scanty to show the difference in patients and operators' radiation exposures by using tailored equipment settings. We aim to apply customized fluoroscopy protocols based on low fps and other customizable settings (thickness of the spectral beam filters, peak tube voltage and peak cathode current, live zoom (1.4 factors with 12 inch FOV), fluoro store and Spot fluoroscopy) and then assess if they significantly affect the radiation exposure of the patient and the interventionist.

Conditions

Interventions

OTHER

Fluoroscopy settings for image acquisition

X-ray radiation is routinely used for imaging in coronary cath labs. Intervention involves lowering patient and operators X-ray exposure by employing various setting on the fluoroscopy machine.

Sponsors & Collaborators

  • Tabba Heart Institute

    lead OTHER

Principal Investigators

  • Asad Z Pathan, MD · Tabba Heart Institute

Study Design

Allocation
NON_RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
100 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-07-01
Primary Completion
2020-12-31
Completion
2021-03-31

Countries

  • Pakistan

Study Locations

More Related Trials

Entities

Read the full study record