Continuous Glucose Monitoring in At-Risk Newborns
NCT04386005 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2025-08-15
Summary
Hypoglycemia (low blood glucose) is a very common problem in newborns, and has been associated with poor neurodevelopment, cognition, and school performance. At-risk newborns (infants of diabetic mothers \[IDM\], large \[LGA\] and small \[SGA\] for gestational age infants, and late preterm \[LPT\] infants) undergo a hypoglycemia screening protocol that involves numerous intermittent needle sticks to test glucose levels on bedside glucometers; however, continuous glucose monitoring (CGM, currently not approved for clinical use in babies), via a small sensor placed in the thigh (only 1 needle stick), would likely decrease pain while providing continuous glucose levels. This study will evaluate the feasibility, safety, and precision of CGM in at-risk newborns, and determine if this method would decrease the amount of painful procedures and episodes of hypoglycemia missed by intermittent sampling.
As part of regular medical care, participants will undergo intermittent blood glucose screening with heel sticks as per the current hospital standard of care protocol. Regular medical care involves checking the participant's blood glucose via heel stick every few hours using a bedside glucometer, with another heel stick to confirm low values in the laboratory. If the participant has low values, he/she may be treated with oral glucose gel, feedings of breast milk or formula, or intravenous (IV) fluids in the Neonatal Intensive Care Unit (NICU). This research study involves placing a CGM device in addition to undergoing the current blood glucose screening protocol and treatment.
As soon as possible after birth, a continuous glucose monitoring device (Dexcom G7) will be placed on the participant's thigh by a research team member, and will blindly continuously record glucose levels that will be analyzed after discharge. Everyone who agrees to participate in this study will have placement of this experimental device.
The investigational device will stay in place for the same amount of time that a participant is undergoing blood glucose monitoring as per the current standard of care protocol, for a maximum of 7 days. A participant may need to have his/her blood glucose checked after 7 days for regular medical care (and not for research), because his/her glucose concentrations are still low. Being in the research study will not affect a participant's medical care, and will not affect how long he/she needs blood glucose monitoring or treatment.
A research team member will place and remove the CGM. Nurses will evaluate the site of the device for signs of irritation, infection, bleeding, and any other issues at least 3 times per day. After discharge from the hospital, data will be collected from the participant's medical record and participant's mother's medical record, including the participant's sex and birth weight, blood glucose values, details of feedings, treatments given for low glucose concentrations, and NICU admission data. Data that will be collected from the participant's mother's medical record includes age and race, prenatal data, medical history, and medication use. The participant's parents will be asked to fill out a short survey about their experience with this device when it is removed.
Conditions
- Neonatal Hypoglycemia
Interventions
- DEVICE
-
Continuous Glucose Monitoring Device
The Dexcom G7 Glucose Monitoring System (San Diego, CA) reports continuous interstitial blood glucose concentrations every 5 minutes, does not require calibration, and involves only 1 needle stick to place the sensor. The manufacturer recommends that a single sensor may be used for up to 10 days. The Dexcom G7 system is the only FDA approved CGM system for children (age \>2 years).
Sponsors & Collaborators
-
DexCom, Inc.
collaborator INDUSTRY -
Children's Miracle Network
collaborator OTHER -
Milton S. Hershey Medical Center
lead OTHER
Principal Investigators
-
Jeffrey R. Kaiser, MD, MA · Penn State Health Milton S Hershey Medical Center
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 1 Minute
- Max Age
- 2 Weeks
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-08-09
- Primary Completion
- 2026-06-30
- Completion
- 2026-06-30
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Continuous Glucose Monitoring and Preterm Infants
NCT02583776 ·Status: COMPLETED ·Phase: PHASE4
-
Real-time Continuous Glucose Monitoring in Very Low Birth Weight Neonates
NCT01942239 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring in Neonatal Hyperinsulinism
NCT06363929 ·Status: TERMINATED
-
CGM Use in Preterm Infants
NCT05436925 ·Status: COMPLETED
-
Continuous Glucose Monitoring and Cerebral Oxygenation in Preterm Infants
NCT04347590 ·Status: UNKNOWN ·Phase: NA
-
Intrapartum Glucose Control and Risk of Neonatal Hypoglycemia
NCT06643351 ·Status: RECRUITING ·Phase: NA
-
Glucose Monitoring During Threatening Preterm Birth in Patients With and Without Gestational Diabetes Mellitus
NCT03007186 ·Status: COMPLETED
-
Correlation of Continuous Glucose Monitoring and Glucose Tolerance Testing With Pregnancy Outcomes
NCT00850135 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Effect of a Continuous Glucose Monitoring on Maternal and Neonatal Outcomes in Gestational Diabetes Mellitus
NCT02838147 ·Status: UNKNOWN ·Phase: PHASE3
-
Early Investigation of Glucose Monitoring After Gestational Diabetes Pilot
NCT06184373 ·Status: RECRUITING
-
Continuous Glucose Monitoring for Various Degrees of Glucose Intolerance
NCT05491954 ·Status: UNKNOWN
-
Continuous Glucose Monitoring to Detect Postpartum Dysglycemia in Patients With Gestational Diabetes
NCT07034261 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Role of CGMS Usage in Predicting Risk for Hypoglycemia
NCT03481530 ·Status: COMPLETED
-
Follow up Glucose Levels Among Infants of Diabetic Mothers
NCT00337142 ·Status: COMPLETED
-
Hypo-METRICS: Hypoglycaemia - Measurement, ThResholds and ImpaCtS
NCT04304963 ·Status: COMPLETED
-
Does the Use of Continuous Glucose Monitoring (CGM) in the Immediate Postpartum Period in Women With Pregestational Diabetes Admitted to the Hospital Decrease Hypoglycemic Episodes
NCT06141941 ·Status: COMPLETED ·Phase: NA
-
The Effects of RT-CGM on Glycemia and QoL in Patients With T1DM and IHA
NCT01787903 ·Status: COMPLETED ·Phase: NA
-
Intrapartum Glucose Management Among Women With Gestational Diabetes Mellitus
NCT02596932 ·Status: COMPLETED ·Phase: NA
-
Frequency of Glucose Monitoring in Labor
NCT06373432 ·Status: COMPLETED ·Phase: NA
-
Comparing Heel Stick Glucoses in Neonates
NCT04811612 ·Status: UNKNOWN ·Phase: NA
-
Correlation Between Continuous Glucose Monitoring and Intermittent Glucose Monitoring Values and Pregnancy Outcomes
NCT00186004 ·Status: COMPLETED
-
Postpartum Continuous Glucose Monitoring (CGM) Study
NCT05714761 ·Status: COMPLETED ·Phase: NA
-
The Impact of Continuous Glucose Monitoring on Maternal and Infant's Outcomes in Gestational Diabetes
NCT06436326 ·Status: RECRUITING ·Phase: NA
-
Gel for Early Hypoglycaemia Prevention in Preterm Infants
NCT04353713 ·Status: UNKNOWN ·Phase: NA
-
Continuous Glucose Monitoring for Screening for Diabetes in Pregnancy
NCT05430204 ·Status: COMPLETED ·Phase: NA