DuraMesh Laparotomy Closure Following Trauma and Emergency Surgery
NCT04312165 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2023-05-10
Summary
The proposed project aims to evaluate the safety of DuraMesh™ suture for laparotomy closure in an emergent setting, while also providing preliminary efficacy data with regard to incisional hernia prevention. Conventional techniques for laparotomy closure in the setting of an emergency laparotomy or delayed abdominal closure suffer from a lack of durability, with incisional hernia rates of 30-34% reported. While prophylactic planar mesh placement has emerged as a cost-effective strategy to prevent hernia formation in the clean, elective laparotomy setting, higher rates of surgical site complications and increased technical complexity preclude its use in the emergency or contaminated setting. Utilized exactly like conventional suture without any change in surgical closure technique, DuraMesh™ provides the durability of planar mesh reinforcement without the marked increase in foreign material or added surgical complexity. As a result, DuraMesh™ is the only hernia prevention strategy that can be forward-deployed in support of the injured warfighter. While this study is specifically targeted to a gap in the care of the injured warfighter, the potential benefits extend well beyond the military applications. With over 2 million laparotomies performed annually in the United States, and approximately 20% of these resulting in an incisional hernia, the need for an alternative abdominal wall closure strategy is equally dire in the civilian setting. This clinical trial represents an opportunity to drive the needed paradigm shift towards prevention, rather than costly management of incisional hernias. The investigators anticipate this work will rapidly lead to further research, including providing the preliminary data necessary to launch a multi-center randomized controlled trial to assess the clinical efficacy of DuraMesh™ for hernia prevention in both the emergent and elective operative settings.
Conditions
- Hernia Incisional
- Suture, Complication
Interventions
- DEVICE
-
Duramesh Laparotomy Closure
Closure of midline laparotomy incision with experimental suture
- DEVICE
-
Conventional suture closure
Closure of midline laparotomy incision with standard suture
Sponsors & Collaborators
-
Uniformed Services University of the Health Sciences
lead FED
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-05-31
- Primary Completion
- 2024-05-31
- Completion
- 2025-05-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Does the Use of Prophylactic Mesh Reduce Incisional Hernia?
NCT04700956 ·Status: COMPLETED ·Phase: NA
-
Prevention of Incisional Hernia With Mesh-suture at Umbilical Trocar Site.
NCT06251583 ·Status: RECRUITING ·Phase: PHASE3
-
A Study to Determine if Mesh Placement During Bladder Surgery Can Reduce the Chances of Developing a Hernia
NCT02908061 ·Status: COMPLETED ·Phase: PHASE3
-
Study of a New Laparoscopic Technique for Parastomal Hernia Repair With Mesh
NCT00138957 ·Status: WITHDRAWN ·Phase: NA
-
Long-term Follow-up of Prophylactic Mesh Reinforcement After Emergency Laparotomy.
NCT04578561 ·Status: COMPLETED
-
Long Term Outcomes Following Hernia Repair With Mesh
NCT04578340 ·Status: RECRUITING
-
Visible vs. Non-Visible Mesh in Underlay Positon After Repair of Umbilical Hernias
NCT03200405 ·Status: COMPLETED ·Phase: NA
-
Hernia-Prophylaxis in Acute Care Surgery H-PACS
NCT03090022 ·Status: COMPLETED ·Phase: NA
-
Primary Mesh Closure of Abdominal Midline Wounds
NCT00761475 ·Status: COMPLETED ·Phase: PHASE3
-
ProGripTM Self-Gripping Polyester Mesh in Incisional Hernia Prevention
NCT03912662 ·Status: TERMINATED ·Phase: NA
-
The Economic Impact of Four Varieties of Mesh Inguinal Hernia Repair- a Double-Blinded, Prospective, Randomized Trial
NCT00416364 ·Status: TERMINATED
-
Comparative Effectiveness Multicenter Trial for Adhesion Characteristics of Ventral Hernia Repair Mesh
NCT01355939 ·Status: COMPLETED
-
Mesh Augmented Reinforcement of Abdominal Wall Suture Line to Limit the Rate of Incisional Hernia Occurrence
NCT05424484 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Prevention of Parastomal Hernia by Primary Mesh Insertion
NCT00641342 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
The Time-Dependent Development of Incisional Hernias in Emergency Laparotomy Incisions of High-Risk Patients
NCT05528692 ·Status: WITHDRAWN
-
Trial Concerning the Frequency of Parastomal Hernia With or Without a Mesh
NCT00917995 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
PROphylactic Mesh to Prevent Incisional Hernias at the Former Stoma Site: the PROMISS-trial
NCT03750942 ·Status: UNKNOWN ·Phase: NA
-
The Mesh-RTL Project, for Prevention of Incisional Hernia
NCT04134455 ·Status: COMPLETED ·Phase: NA
-
Comparison of Whole Mesh and Split Mesh Use in Laparoscopic Inguinal Hernia Repair
NCT05420376 ·Status: UNKNOWN ·Phase: NA
-
Late Mesh Complications After 3258 Incisional Hernia Operations
NCT02263612 ·Status: COMPLETED
-
Long Term Complaints After Elective Repair for Small Umbilical or Epigastric Hernias
NCT01501682 ·Status: UNKNOWN
-
The Use of Local Hemostatic in Patients With Large Incisional Hernias
NCT04222517 ·Status: COMPLETED ·Phase: NA
-
Usefulness of a Prothetic Absorbable Mesh in Incisional Hernia Prevention After Midline Laparotomy
NCT02208557 ·Status: UNKNOWN ·Phase: PHASE4
-
Long Term Results of Randomized Prospective Comparison of Onlay and Sublay Mesh Repair Techniques for Incisional Hernia
NCT02314091 ·Status: COMPLETED ·Phase: NA
-
Role of Mesh Stoma Reinforcement Technique (MSRT) in Prevention of Parastomal Hernia After Ileal Conduit Urinary Diversion
NCT02387333 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3