Personalized Vs. Standard Duration of Dual Antiplatelet Therapy and New-generation Polymer-Free vs- Biodegradable-Polymer DES

NCT04135989 · Status: ACTIVE_NOT_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 2106

Last updated 2024-02-23

No results posted yet for this study

Summary

New-generation metallic drug-eluting stents represent the standard of care among patients undergoing percutaneous coronary intervention (PCI). Currently, few data are available as regards to the safety and efficacy of the Cre8 amphilimus-eluting stent (Cre8 AES, Alvimedica, Instanbul, Turkey) in comparison with the biodegradable polymer everolimus-eluting stent (Synergy EES, Boston Scientific, Marlborough, MA, USA). Results from randomized trials and meta-analyses consistently indicate that prolonged dual antiplatelet therapy (DAPT) after PCI reduces ischemic events, but invariably conveys an excess of clinically relevant bleeding, which is proportional to the duration of treatment. It has been estimated, indeed, that for every non-fatal ischemic event avoided with prolonged DAPT, two or more clinically relevant bleeding events have to be expected. Given the trade-off between benefits and risks and the lack of mortality benefit in favor of prolonged DAPT, expert consensus suggests that DAPT duration should be individualized based on ischemic versus bleeding risks. At this regard, the DAPT score has been recently proposed as standardized tool to identify patients who derive benefit or lack from a prolonged course of DAPT. However, a prospective assessment of the DAPT score is lacking and whether a personalized duration of DAPT based on the DAPT score improves the net clinical benefit remains unknown.

The objective of the study is to compared the safety and the efficacy of the Cre8 AES with the Synergy EES and a personalized DAPT duration based on the DAPT score with a standard DAPT duration among patients undergoing PCI.

Conditions

Interventions

DEVICE

Percutaneous coronary intervention with implantation of amphilimus-eluting stents for coronary artery disease.

Implantation of polymer-free, amphilimus-eluting, drug-eluting stents

DEVICE

Percutaneous coronary intervention with implantation of everolimus-eluting stents for coronary artery disease.

Implantation of biodegradable-polymer, everolimus-eluting, drug-eluting stents

DRUG

Personalized DAPT duration

Duration of dual antiplatelet therapy according to DAPT score for 3- or 6- months in patients with low DAPT score (stable CAD or ACS, respectively) or for 24-months in patients with high DAPT score

DRUG

Standard DAPT duration

Duration of dual antiplatelet therapy for 12 months.

Sponsors & Collaborators

  • AdvicePharma Group

    collaborator UNKNOWN
  • Federico II University

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
FACTORIAL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-01-01
Primary Completion
2021-10-24
Completion
2024-10-24

Countries

  • Italy

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04135989 on ClinicalTrials.gov