Bio Impedance-assisted Monitoring of Chronic Hemodialysis Patients
NCT04127877 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2019-10-16
Summary
Hemodynamic trends will be assessed using the device, in 100 dialysis sessions in 30 patients, who are prone to develop hypotensive episode during dialysis. Sitting blood pressures will be measured immediately prior to each hemodynamic measurement: before initiation of dialysis, every each hour and in the beginning of hypotension episode, just before the end and 10 min after the end of the treatment.
Gender, age, height, weight, electrode location and blood pressure data will be entered into the device. The device will measure and calculate hemodynamic parameters on each heart beat during 60 s and provides the averaged parameters.
Technology for hemodynamic measurements:
The device (NICaS, NI Medical) is a noninvasive regional bioimpedance cardiac measurement and analysis system (FDA 510k clearance no. K080941, 12 June 2009). The US Food and Drug Administration indication for use of the device states 'NICaS is intended to monitor and display hemodynamic parameters in males and females with known or suspected cardiac disorders needing cardiac assessment'.
SV will be measured by applying an alternating electrical current of 1.4mA at 30 kHz frequency through the patient's body via two pairs of tetrapolar sensors, one pair placed on the wrist of the nonaccess arm above the radial pulse and the other pair on the contralateral ankle above the posterior tibial pulse (Figure 1).
Figure 1 : Sensor location
SV is calculated by Frinerman's formula:
SV¼(dR/R) - q - (L2/Ri) - (ab)/b - KW - HF \[2-4\], where dR is the impedance change in the arterial system as a result of intraarterial expansion during systole, R is basal resistance, q is blood electrical resistance, L is the patient's height, Ri is basal resistance corrected for gender and age, KWis the correction of weight according to ideal values, HF is a hydration factor that takes into account the ratio between R and body mass index (BMI), which is correlated to body water volume, ab is the electrocardiogram (ECG) R-R wave interval and b is the diastolic time interval. SV is automatically calculated every 20 s and is the average of three measurements obtained consecutively during 60 s of monitoring. The SV index is calculated as SV/body surface area using the Du Bois formula \[11\]. Heart rate is calculated from a one channel ECG and cardiac (output) index¼SV index - heart rate/1000. Using an oscillometric method, sitting systolic and diastolic blood pressure measurements were made automatically by the dialysis machine. Mean arterial pressure \[2 - (diastolicsystolic)/3\], cardiac power index \[CPI; mean arterial pressure (MAP) -cardiac index - 0.0022 w/m2; normal range 0.45-0.85w/m2\] \[12, 13\] and total peripheral resistance (MAP/ cardiac index - 80 dyn - s/cm5 - m2; normal range 1600-3000 dyn - s/cm5- m2) \[13\] will be calculated.
As the device measures pulsatile flow and is blinded to constant flow, fluid removal during dialysis has no impact on measurement accuracy. This was recently validated by correlating SV to ECG measurements during hemodialysis treatments. Good correlation was maintained during treatment. Further, NICaS performance immunity to fluid reduction was demonstrated by the maintenance of correlation to ECG results throughout dialysis treatments \[9\]. The results are drawn on hemodynamic graphs showing the MAP (y-axis) as a function of cardiac index (x-axis); curves of total peripheral resistance index (TPRI) and CPI are displayed. Ranges for the normal population are depicted by a dotted octagon.
Conditions
- Chronic Kidney Diseases
- Hemodialysis Complication
Interventions
- DEVICE
-
NICAS
Electric regional bio impedance device
Sponsors & Collaborators
-
Assuta Ashdod Hospital
lead OTHER
Principal Investigators
-
Adi Leiba, Prof · ASSUTA HOSPITAL ASHDOD
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-11-18
- Primary Completion
- 2019-12-31
- Completion
- 2020-12-31
Countries
- Israel
Study Locations
More Related Trials
-
Evaluation of Non-Invasive Continuous vs Intermittent BloodPressure Monitors in Maintenance Dialysis (BP Dialysis)
NCT05540457 ·Status: COMPLETED ·Phase: NA
-
Haemodialysis Outcomes & Patient Empowerment Study 02
NCT04623281 ·Status: COMPLETED
-
BIS-guided Fluid Management in HD Patients
NCT05272800 ·Status: COMPLETED ·Phase: NA
-
Body Composition Monitor Among Daily Home Dialysis With Low Flow Dialysate
NCT03994133 ·Status: UNKNOWN
-
Fluid Management Guided by Bioimpedance Analysis in Peritoneal Dialysis(PD) Patients.
NCT02000128 ·Status: COMPLETED ·Phase: NA
-
Effects of Intradialytic Exercise as Assessed by Bioimpedance Analysis and Blood Volume Monitoring
NCT01273753 ·Status: COMPLETED ·Phase: NA
-
Hemodynamic and Respiratory Tolerance of Intermittent Hemodialysis in Critically Ill Patients
NCT04444765 ·Status: COMPLETED
-
Green Dialysis: Dialysis With Reduced Dialysate Flow
NCT05974436 ·Status: COMPLETED ·Phase: NA
-
Body Composition Monitor(BCM) Guided Fluid Management in Maintenance Hemodialysis (MHD) Patients
NCT01509937 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Bioimpedance Method for Determination of Dry Weight in Dialysis Patients
NCT00397306 ·Status: COMPLETED ·Phase: NA
-
BIA Versus Physician Adjustment in Acute Kidney Injury Patients Requiring Renal Replacement Therapy
NCT03916861 ·Status: COMPLETED ·Phase: NA
-
A Single Arm, Multi-Center Study To Evaluate The Intelligent Dialysis Assistant (IDA)
NCT04808011 ·Status: UNKNOWN ·Phase: NA
-
Changes in Volumetric Hemodynamic Parameters Induced by Fluid Removal on Hemodialysis
NCT02485782 ·Status: COMPLETED
-
Adjusting Fluid Removal Based on Blood Volume in Hemodialysis: A Randomized Study
NCT01988181 ·Status: COMPLETED ·Phase: NA
-
Control Of Fluid Balance Guided by Body Composition Monitoring in Patients on PeritoneAl dialySiS
NCT01887262 ·Status: COMPLETED ·Phase: NA
-
Intracellular Phosphate Concentration Evolution During Hemodialysis by MR Spectroscopy
NCT03119818 ·Status: COMPLETED ·Phase: NA
-
Functional Urodynamic Changes in Chronic Kidney Disease Patients and Does Insertion of Urinary Catheter Delay the Need for Kidney Dialysis
NCT02731209 ·Status: UNKNOWN ·Phase: NA
-
Bioimpedance as a Tool for Fluid Management in Peritoneal Dialysis (PD) Patients
NCT00801112 ·Status: UNKNOWN
-
Individualized Incremental Hemodialysis Study
NCT03352271 ·Status: COMPLETED ·Phase: NA
-
Continuous Registration of Bioimpedance During Hemodialysis
NCT03990818 ·Status: UNKNOWN
-
Efficacy of Combined Low- and High- Frequency Stimulation in Peripheral Muscle Function During Hemodialysis
NCT03779126 ·Status: RECRUITING ·Phase: NA
-
Comparison of Body Hydration State in Hemodialysis Patients
NCT01814254 ·Status: TERMINATED
-
Reducing Arrhythmia in Dialysis by Adjusting the Rx Electrolytes/Ultrafiltration, Study A
NCT03519347 ·Status: COMPLETED ·Phase: NA
-
the Effect of Virtual Reality Exercise on Selected Electrolytes Levels in Intradialytic Patients
NCT07316725 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Acid-Base Composition With Use of hemoDialysates
NCT02334267 ·Status: COMPLETED ·Phase: NA