Self-compression Mammography in Clinical Practice

NCT04009278 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 502

Last updated 2025-06-12

No results posted yet for this study

Summary

Every year millions of mammograms are performed worldwide, representing the primary examination for the early diagnosis of breast cancer. Despite continuous advances in medicine and technology, an aspect of mammography has not changed in over fifty years: the breast is still compressed on the detector because this allows to reduce the thickness of the breast thus improving the quality of the diagnostic image and reducing the dose of radiation necessary to obtain a clear image. Many women perceive as painful this compression, including women who have been treated for breast cancer.

Pain can discourage asymptomatic women to present themselves periodically to screening mammography, while an increasing number of women in follow-up after conservative surgery have to withstand the pain caused by mammography.

Some studies mention various factors that are responsible for pain when performing mammography: breast sensitivity, anxiety level, expected pain and staff attitude. Some studies have also identified breast density, breast volume and menstrual phase as other influencing factors, although not all studies support these hypothesis. The technical characteristics of the equipment can greatly affect annoyance, sense of oppression, pain. The technological proposals to reduce the discomfort of the patients concern various items: flexible compressors, self-compression devices under the supervision of the technician who performs the positioning and the minimum initial compression, environmental factors such as equipment noise reduction, chromatic, sound and sensory effects (eg: aromatic diffusers).

The aim of our study is to evaluate the effectiveness of the self-compression compared to the standard one, in reducing annoyance, a sense of oppression and pain, and to evaluate the difference of the average glandular dose given to the woman for each projection.

Self-compression may help reaching better compression tolerating the discomfort and pain induced thus allowing to achieve a lower thickness, a lower glandular dose and a better image.

Conditions

Interventions

OTHER

Self compression arm

The optimal compression level up will be under the supervision of the radiographer who will interpose the compression when a level is reached beyond which there is no further reduction in thickness (15 daN). If the woman stops at a compression of less than 10 daN and that the radiographer considers not adequate to perform a quality mammogram, the radiographer will perform the compression in conventional mode and record the passage of compression mode.

Sponsors & Collaborators

  • Azienda USL Reggio Emilia - IRCCS

    lead OTHER_GOV

Principal Investigators

  • Laura Canovi, RT · Arcispedale S.Maria Nuova

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Months
Sex
FEMALE
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-01-25
Primary Completion
2019-07-31
Completion
2020-12-31

Countries

  • Italy

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04009278 on ClinicalTrials.gov