Management of Moderately Hypoxemic Thoracic Trauma

NCT03997630 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 770

Last updated 2025-05-14

No results posted yet for this study

Summary

In France, the average incidence of thoracic trauma is 10,000 to 15,000 each year. These patients are at risk of early and late post traumatic respiratory complications as follows: pneumonia, Acute Respiratory Distress Syndrome (ARDS), hypoxemia. Main issues of thoracic trauma management were recently published by French anesthesiologist and intensivist experts. Non-invasive ventilation (NIV) was recommended in case of severe hypoxemia (PaO2/FiO2 \< 200). In comparison to conventional oxygenation or mechanical ventilation, NIV reduced length of stay, incidence of complications and mortality in case of severe hypoxemia. For mild or moderate hypoxemic patients, no devices were tested to prevent respiratory complications. At the moment, low-flow oxygenation is administered to these patients in the absence of severe hypoxemia. Recently, many studies have found promising results with high-flow oxygenation delivered by nasal cannula. This device has many physiological advantages: wash out the naso-pharyngeal dead space, increase end expiratory lung volume, deliver a moderate or low level of Positive end-expiratory pressure (PEEP), improve work of breathing and confort. Several randomized controlled trials tested this device in many clinical settings, but there are no studies on its use after thoracic trauma. A comparative trial is needed to evaluate early prophylactic administration of high-flow oxygenation after thoracic trauma.

Conditions

  • Chest Trauma
  • High Flow Oxygenation

Interventions

DEVICE

High flow Oxygenation

Interventional group: All patients included in this group will receive a continuous heated and humidified high-flow (30 to 60 l/min) oxygenation with a nasal cannula for 48 hours. Initially, flow rate will be started at 50 l/min with a FiO2 at 50%. According to the protocol, flow rate and FiO2 will be titrated on SpO2 and respiratory tolerance. Weaning and failure of high-flow oxygenation are described in detail in the study protocol.

DEVICE

Standard oxygen

Control group: All patients included in this group will receive a low flow oxygenation (flow rate \< 15 l/min) with nasal cannula (flow rate ≤ 6 l/min) or non-rebreathing mask (flow rate ≥ 7 l/min).

Sponsors & Collaborators

  • University Hospital, Brest

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-11-12
Primary Completion
2026-02-28
Completion
2026-02-28

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03997630 on ClinicalTrials.gov