Management of Moderately Hypoxemic Thoracic Trauma
NCT03997630 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 770
Last updated 2025-05-14
Summary
In France, the average incidence of thoracic trauma is 10,000 to 15,000 each year. These patients are at risk of early and late post traumatic respiratory complications as follows: pneumonia, Acute Respiratory Distress Syndrome (ARDS), hypoxemia. Main issues of thoracic trauma management were recently published by French anesthesiologist and intensivist experts. Non-invasive ventilation (NIV) was recommended in case of severe hypoxemia (PaO2/FiO2 \< 200). In comparison to conventional oxygenation or mechanical ventilation, NIV reduced length of stay, incidence of complications and mortality in case of severe hypoxemia. For mild or moderate hypoxemic patients, no devices were tested to prevent respiratory complications. At the moment, low-flow oxygenation is administered to these patients in the absence of severe hypoxemia. Recently, many studies have found promising results with high-flow oxygenation delivered by nasal cannula. This device has many physiological advantages: wash out the naso-pharyngeal dead space, increase end expiratory lung volume, deliver a moderate or low level of Positive end-expiratory pressure (PEEP), improve work of breathing and confort. Several randomized controlled trials tested this device in many clinical settings, but there are no studies on its use after thoracic trauma. A comparative trial is needed to evaluate early prophylactic administration of high-flow oxygenation after thoracic trauma.
Conditions
- Chest Trauma
- High Flow Oxygenation
Interventions
- DEVICE
-
High flow Oxygenation
Interventional group: All patients included in this group will receive a continuous heated and humidified high-flow (30 to 60 l/min) oxygenation with a nasal cannula for 48 hours. Initially, flow rate will be started at 50 l/min with a FiO2 at 50%. According to the protocol, flow rate and FiO2 will be titrated on SpO2 and respiratory tolerance. Weaning and failure of high-flow oxygenation are described in detail in the study protocol.
- DEVICE
-
Standard oxygen
Control group: All patients included in this group will receive a low flow oxygenation (flow rate \< 15 l/min) with nasal cannula (flow rate ≤ 6 l/min) or non-rebreathing mask (flow rate ≥ 7 l/min).
Sponsors & Collaborators
-
University Hospital, Brest
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-11-12
- Primary Completion
- 2026-02-28
- Completion
- 2026-02-28
Countries
- France
Study Locations
More Related Trials
-
ORI to Reduce Hyperoxia After Out Hospital Cardiac Arrest
NCT03653325 ·Status: COMPLETED ·Phase: NA
-
Pre-hospital Hypoxemia in Trauma Patients
NCT01074983 ·Status: COMPLETED
-
Feasibility of End-tidal Oxygen Concentration Monitoring During Preoxygenation for Intubation in the Intensive Care Unit.
NCT05409573 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Non-Invasive Hemoglobin in Trauma Patients
NCT03123328 ·Status: COMPLETED ·Phase: NA
-
PreOxygenation for EndoTracheal Intubations
NCT03240614 ·Status: TERMINATED ·Phase: NA
-
Impact of Continuous Monitoring of PtC02 on Ventilatory Weaning in Neuro-injured Patients
NCT04819984 ·Status: UNKNOWN ·Phase: NA
-
Effects of Laryngeal Tube Ventilation on no Flow Time During Out of Hospital Cardiac Arrest
NCT01295749 ·Status: COMPLETED ·Phase: PHASE3
-
Cerebral Circulation in Critically Ill Children
NCT03731104 ·Status: COMPLETED
-
Accuracy and Precision of Different Devices for the Monitoring of Pulsed Oxygen Saturation
NCT02832817 ·Status: UNKNOWN
-
Effect of Short-term Oxygen During CPET in GUCH
NCT04076501 ·Status: COMPLETED ·Phase: NA
-
Assessment of Preoxygenation Strategies in the Prehospital Environment
NCT02694705 ·Status: COMPLETED ·Phase: NA
-
Left Ventricular Outflow Tract Mean Velocity in Children: a Strong Alternative to Cardiac Index in Pediatric Intensive Care Unit
NCT06837727 ·Status: COMPLETED
-
Cardiotoxicity of Carbon Monoxide in Patients Treated With Hyperbaric Oxygen Therapy
NCT06549621 ·Status: RECRUITING
-
FreeO2 PreHospital - Automated Oxygen Titration vs Manual Titration According to the BLS-PCS
NCT03696563 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Virtual Reality on Pulmonary Recovery and Mobility in Patients With Blunt Chest Trauma
NCT05194176 ·Status: TERMINATED ·Phase: NA
-
Double Trunk Mask and Standard Nasal Cannula During Acute Hypoxia
NCT03457363 ·Status: COMPLETED ·Phase: NA
-
Validation of Vital Signs Recording With VT-Patch Connected Devices in Children
NCT05451875 ·Status: RECRUITING
-
Automated Chest Compression in Cardiac Arrest
NCT00641069 ·Status: COMPLETED
-
Use of Diffuse Optical Spectroscopy for Evaluation of the Trauma/Critically Care Patients
NCT00581295 ·Status: COMPLETED
-
Intrahospital Transport in Patients With High-flow Nasal Oxygenation: Prospective Observational Study
NCT05311007 ·Status: COMPLETED
-
Validity of Radical 7 Masimo Monitor at Measuring Hemoglobin in Pediatric Cardiac Intensive Care
NCT03977142 ·Status: UNKNOWN
-
Clinical Audit of Cardio Pulmonary Resuscitation Management in Adults Patient Units of Care by in Situ Simulation
NCT02065934 ·Status: COMPLETED
-
Characterizing the cerebrovAscular Physiology of Optimal Mean Arterial Pressure Targeted Resuscitation
NCT03609333 ·Status: COMPLETED ·Phase: NA
-
The Impact of Real Time Ventilation Feedback on Ventilation Rate and Tidal Volume During Cardiac Arrest.
NCT06528704 ·Status: RECRUITING ·Phase: NA
-
Monitoring of Patient Physiological Parameters in Real Life Using OXYFLEX® Biosensors Versus Standard Monitoring
NCT07037784 ·Status: NOT_YET_RECRUITING ·Phase: NA