Non-Invasive Blood Test Cross-Validation Study
NCT03991637 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 90
Last updated 2019-06-24
Summary
The study considers a cross-validation approach to determine the effectiveness of a non-invasive comprehensive metabolic panel (NICMP), relative to the venipuncture method. The NICMP machine learned powered device utilizes a light sensor to capture readings from either palm. The study (n=90) proves an agreement and strong correlation with respect to the NICMP and venipuncture blood draw.
Conditions
- Reproducibility of Results
- Safety Issues
Interventions
- DEVICE
-
Non-Invasive Comprehensive Metabolic Panel
The device utilizes spectroscopy and machine learning to detect metabolic analyte concentrations.
Sponsors & Collaborators
-
University of North Dakota
collaborator OTHER -
Joseph Allen Jr.
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- FACTORIAL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2018-07-18
- Primary Completion
- 2018-09-11
- Completion
- 2019-03-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Optical Detection of Intravenous Infiltration
NCT01126710 ·Status: COMPLETED
-
A Comparator Study of a Tasso Device Blood Sample to Traditional Venous Blood Sample for CBC
NCT06360952 ·Status: NOT_YET_RECRUITING
-
Clinical Performance of Capillary Blood Samples Collected Using the Tasso+ Serum Gel Capillary Blood Collection System for Clinical Chemistry Testing of 14 Analytes on an Abbott Alinity Analyzer
NCT07260799 ·Status: RECRUITING
-
Evaluation of the Zynex Blood Volume Monitor in Healthy Adult Volunteers During a Blood Draw
NCT01834612 ·Status: COMPLETED ·Phase: PHASE1
-
Prospective Study to Validate the Clinical Accuracy of Norbert Device to Measure Body Temperature
NCT05640310 ·Status: WITHDRAWN
-
A Study to Compare Analyte Levels in Blood Collected Using an Investigational Collection Device With a Commercial Predicate
NCT01934842 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of a Training Model for the Proficient Use of the Belmont Rapid Infuser
NCT02059109 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Tasso+ Blood Self-Collection for Clinical Diagnostic Assessment of Various Biomarkers
NCT05852925 ·Status: RECRUITING ·Phase: NA
-
Evaluating Technologies for Point-of-Care Blood Collections by Patients
NCT06507566 ·Status: COMPLETED ·Phase: NA
-
Comparison of Noninvasive Hemoglobin Disposable Sensors
NCT03125031 ·Status: COMPLETED ·Phase: NA
-
Estimating Blood [Lactate] Non-Invasively
NCT05036122 ·Status: WITHDRAWN ·Phase: NA
-
Noninvasive Measurement of Blood Coagulation
NCT03217799 ·Status: UNKNOWN
-
Validation of Diagnostics to Identify Glucose-6-phosphate Dehydrogenase Activity in the US
NCT04010695 ·Status: COMPLETED ·Phase: NA
-
A Multi-site Clinical Evaluation of Capillary Blood Samples Collected Using the Tasso+SST Device for Downstream Analyte Testing
NCT06392269 ·Status: COMPLETED
-
Clinical Validation of the Fluispotter System for Serial Sampling of Venous Dried Blood Spots
NCT04594577 ·Status: COMPLETED ·Phase: NA
-
A Trial to Evaluate the Precision and Accuracy of the NBM-200 Series When Used in a Continuous Prospective Mode
NCT01917487 ·Status: UNKNOWN
-
Biospecimen Analysis in Detecting Chemical Concentrations in Patients With Chronic or Infectious Diseases Receiving Meditations
NCT04160429 ·Status: RECRUITING
-
Evaluation of Physiological Variables and Detection of Blood Loss in Healthy Adults With Different Subject Positioning by the CM-1500
NCT05980013 ·Status: COMPLETED ·Phase: NA
-
Generation of Positive Biological Samples to Epoetin for Doping Control.
NCT02920372 ·Status: COMPLETED ·Phase: PHASE1
-
Evaluation of the Spectra Optia PMN Cell Collection Procedure
NCT01805180 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Noninvasive Hemoglobin Sensor (Rainbow Reusable DCI)
NCT03124758 ·Status: COMPLETED ·Phase: NA
-
Temporal Pattern of Circulating DNA for Patients Receiving Irradiation
NCT01099020 ·Status: TERMINATED
-
Evaluation of the Zynex Blood Volume Monitor in Healthy Adult Patients During a Blood Draw
NCT01846195 ·Status: COMPLETED ·Phase: NA
-
Non-Invasive Hemoglobin Study
NCT02206399 ·Status: COMPLETED
-
Effect of Skin Pigmentation and Race/Ethnicity Factors on the Accuracy of Masimo Pulse Oximeters
NCT04889222 ·Status: TERMINATED