Speech Perception Performance With Gap-interleaved Stimulation Paradigms
NCT03937388 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 8
Last updated 2019-09-26
Summary
Cochlear implants (CI) are used to help patients with severe to profound hearing loss regain auditory perception by electrical stimulation of the auditory nerve. The electrical stimulation consists of trains of charge balanced, biphasic current pulses. For each patient, individual stimulation parameters (perception threshold, most comfortable level - MCL) are determined for each electrode during fitting sessions. However, an important parameter, pulse duration, cannot be individualized for each electrode. There are certain circumstances where it would be advantageous to have the possibility of introducing variable pulse durations into the fitting strategy (e.g., optimization of energy consumption, development of combined cochleo-vestibular implants). However, since in current CI systems pulses are transmitted sequentially, introducing varying pulse widths would also introduce "gaps" (zero-stimulation periods) into the stimulation profile. The influence of such auditory gaps on speech recognition and on the quality of hearing has not been explored yet, but can be investigated in current CI users. The objective of this study is to investigate the impact of time-fixed gaps (zero-stimulation periods) in the cochlear stimulation strategy on speech performance and hearing quality.
Conditions
- Deafness
- Hearing Loss
Interventions
- OTHER
-
Cochlear stimulation strategy including time-fixed gaps
Investigation of the impact of time-fixed gaps (zero-stimulation periods) in the cochlear stimulation strategy on speech performance and hearing quality.
Sponsors & Collaborators
-
University of Innsbruck / Department of Mechatronics
collaborator UNKNOWN -
Angelica Perez Fornos
lead OTHER
Principal Investigators
-
Angelica Perez Fornos, PhD · University Hospital, Geneva
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-03-06
- Primary Completion
- 2019-06-28
- Completion
- 2019-06-30
Countries
- Switzerland
Study Locations
More Related Trials
-
Stimulating the Cochlear Apex Without Longer Electrodes
NCT06901674 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Auditory Neuropathy and Cochlear Implants
NCT01023932 ·Status: COMPLETED
-
Cochlear Implanted Listening Effort and Hearing Attention
NCT04733950 ·Status: RECRUITING ·Phase: NA
-
Electric Pace-pitched Hearing Achieves Natural Tonotopy
NCT03892941 ·Status: UNKNOWN ·Phase: NA
-
Subjective Evaluation of a Sound Processing Method for Hearing Aids on Auditory Distance Perception
NCT03512951 ·Status: COMPLETED ·Phase: NA
-
Speech Performance and Clinic Efficiency With Remote Care Compared With Standard of Care in Adults With a Cochlear Implant in the First 12 Months Post-activation
NCT05552118 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of a Method to Improve Cochlear Implant Users' Speech Perception in Noisy Environments While Maintaining Their Ability to Determine Where a Sound Originates From
NCT07323862 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Perceptual Adaptation Following Cochlear Implantation (Aim 3a)
NCT07039435 ·Status: RECRUITING ·Phase: NA
-
Evaluation and Optimization of Hearing Devices in 3-D Complex Audio Environments
NCT03514758 ·Status: COMPLETED ·Phase: NA
-
Comparison of Unilateral CI vs. Bimodal Stimulation in Prosodic Perception
NCT06128161 ·Status: COMPLETED
-
MeasurIng and Restoring Auditory Awareness for Cochlear Implant Listeners in noisE
NCT06420921 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of a Bio-inspired Coding Strategy for Cochlear Implant Users
NCT03726684 ·Status: COMPLETED ·Phase: NA
-
Exploration of the Functional Effect of Different Hearing Aid Noise Reduction Algorithms in an Ecologically Valid Conversational Situation
NCT06992310 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Electrophysiological Study of Interindividual Differences in Speech-understanding Among Cochlear Implant Patients
NCT01805167 ·Status: UNKNOWN ·Phase: NA
-
Channel Interaction in Cochlear Implant and Speech Understanding in Noise
NCT03877211 ·Status: COMPLETED ·Phase: NA
-
Study of Auditory Performance on Prosodic Tests in Cochlear Implanted Subjects Using a Fine Structure Strategy
NCT03694704 ·Status: WITHDRAWN ·Phase: NA
-
Electrocochleography Function for Monitoring Residual Hearing
NCT03848338 ·Status: UNKNOWN ·Phase: NA
-
Single-sided Deafness and Cochlear Implants
NCT01749592 ·Status: COMPLETED ·Phase: NA
-
Impact of Music Therapy on Speech Intelligibility in Noise With Cochlear Implants
NCT06734897 ·Status: RECRUITING ·Phase: NA
-
Objective Measures in Cochlear Implant
NCT03260374 ·Status: UNKNOWN
-
Impact of Anatomy-Based Cochlear Implant Programming on Early Performance
NCT06734039 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Assessment of Novel Sound Changing Principles in Hearing Instruments to Determine Their Application
NCT03780374 ·Status: COMPLETED ·Phase: NA
-
Effects of Pulses on Loudness
NCT04010721 ·Status: COMPLETED ·Phase: NA
-
Optimization of Cochlear Implant MAP-parameters in Children
NCT03694340 ·Status: COMPLETED ·Phase: NA
-
Speech Perception for Children With Cochlear Implants
NCT01059838 ·Status: COMPLETED ·Phase: NA