Comparison of Er,Cr:YSGG and Diode Lasers In Second Stage Implant Surgery

NCT03819244 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40

Last updated 2019-01-29

No results posted yet for this study

Summary

The study evaluates postoperative pain, intraoperative bleeding and wound healing after second stage implant surgery. Submerged implants were exposed with diode laser in Group 1 (n=20) and by using Er,Cr:YSGG laser in Group 2 (n=20).

Conditions

  • Postoperative Pain
  • Soft Tissue Bleeding
  • Wound Heal

Interventions

DEVICE

940 nm Gallium Aluminum Arsenide Diode Laser

Exposure of the cover screw of osseointegrated dental implants embedded under oral mucosa by performing the soft tissue incision with diode laser for placing the healing abutment.

DEVICE

2780 nm Er,Cr:YSGG Laser

Exposure of the cover screw of osseointegrated dental implants embedded under oral mucosa by performing the soft tissue incision with erbium laser for placing the healing abutment.

Sponsors & Collaborators

  • Yuzuncu Yıl University

    lead OTHER

Principal Investigators

  • Erkan Feslihan, DDS · Yuzuncu Yıl University

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
70 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2017-11-27
Primary Completion
2018-05-24
Completion
2018-08-20
FDA Device
Yes

Countries

  • Turkey (Türkiye)

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.