Study of a Novel Interposition Supraciliary Implant in Patients With Open Angle Glaucoma
NCT03736655 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27
Last updated 2021-12-20
Summary
The purpose of this study is to evaluate the safety and effectiveness of a novel interposition supraciliary implant as a stand-alone therapy for lowering intraocular pressure (IOP) in patients with primary open angle glaucoma (POAG) who have failed at least one class of topical medical therapy
Conditions
- Glaucoma, Open-Angle
Interventions
- DEVICE
-
Interposition supraciliary implant
Surgical placement of an interposition supraciliary implant in the supraciliary space
Sponsors & Collaborators
-
Ciliatech
lead INDUSTRY
Principal Investigators
-
Philippe SOURDILLE · Ciliatech
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 50 Years
- Max Age
- 99 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-03-15
- Primary Completion
- 2021-04-01
- Completion
- 2021-10-25
Countries
- France
Study Locations
More Related Trials
-
Prospective Evaluation of Open-Angle Glaucoma Subjects on One Topical Hypotensive Medication Treated With Two iStents
NCT01252862 ·Status: COMPLETED ·Phase: PHASE4
-
Purpose of This Study is to Evaluate the Safety and Efficacy of One, Two, or Three iStents for the Reduction of Intraocular Pressure in Open-angle Glaucoma Subjects
NCT01252849 ·Status: COMPLETED ·Phase: NA
-
MINIject Glaucoma Implant in European Patients
NCT03624361 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the XEN Implant in Moderate Primary Open Angle Glaucoma (POAG) Participants
NCT02006693 ·Status: COMPLETED ·Phase: PHASE4
-
Evaluate Efficacy, Safety, Tolerability and Biodegradation of PA5346 Ocular Implant in Patients With Open-Angle Glaucoma or Ocular Hypertension
NCT06964061 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE1
-
A Study of the iStent in Combo With Cataract Surgery in Newly Diagnosed Open Angle Glaucoma or OH Patients.
NCT00326066 ·Status: COMPLETED ·Phase: NA
-
A Prospective Evaluation of Open-Angle Glaucoma Subjects on Two Topical Hypotensive Medications Treated With One Suprachoroidal Stent
NCT01252914 ·Status: COMPLETED ·Phase: PHASE4
-
Investigation of the iStent Inject® Devices in Open-Angle Glaucoma
NCT03624699 ·Status: COMPLETED ·Phase: NA
-
Study of CyPass Implantation In Patients With Open Angle Glaucoma Refractory to Single or Multi-agent Topical Therapy
NCT01166659 ·Status: COMPLETED ·Phase: NA
-
Clinical Study Evaluating the Efficacy and Safety of CID v2.2 in Glaucoma Surgery
NCT05625958 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Efficacy and Safety of iStent Inject and Inject W in the Management of Primary Open-angle Glaucoma
NCT05062668 ·Status: UNKNOWN
-
Safety and Tolerability of a Prostaglandin Ocular Implant for Treatment of Open Angle Glaucoma
NCT03604328 ·Status: COMPLETED ·Phase: PHASE1
-
Open-Angle Glaucoma Subjects With Cataract Treated With Cataract Surgery Plus One iStent and One iStent Supra
NCT03255785 ·Status: COMPLETED ·Phase: NA
-
A Study of the Trabecular Micro-Bypass Stent in Combination With Cataract Surgery in Open Angle Glaucoma Subjects.
NCT00326014 ·Status: COMPLETED ·Phase: PHASE4
-
Treatment Outcomes of a Novel Glaucoma Tube Shunt Implant for Intraocular Pressure Control in Eyes With Refractory Glaucoma
NCT04297930 ·Status: COMPLETED
-
Long-term Safety and Efficacy of a Modified Suprachoroidal Silicone Tube (SST) Shunt
NCT06691555 ·Status: RECRUITING
-
A Study Evaluating the Safety and Efficacy of MINIject S+ in Subjects With Open Angle Glaucoma
NCT07009236 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Study of the Glaukos Trabecular Micro-bypass Stent in Open Angle Glaucoma Subjects 1 Stent Versus 2
NCT00326079 ·Status: UNKNOWN ·Phase: PHASE4
-
Open-angle Glaucoma Subjects on One Topical Hypotensive Medication Randomized to Treatment With One or Two Trabecular Micro-bypass Stents in Conjunction With Cataract Surgery
NCT01455467 ·Status: COMPLETED ·Phase: NA
-
OMNI 3.1 Surgical System in Subjects With Primary Open-Angle Glaucoma
NCT06991270 ·Status: RECRUITING ·Phase: NA
-
Clinical Study of Glaukos® Trabecular Micro-Bypass System Model iS3 Infinite Vs. Competitor
NCT05127551 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Study of the Glaukos Trabecular Micro-Bypass Stent in Refractory Open Angle Glaucoma Subjects
NCT00326040 ·Status: COMPLETED ·Phase: PHASE4
-
Study of a Cilioscleral Interposition Device (CID) SV22 in Patients With Primary Open Angle Glaucoma and Narrow Angle Glaucoma
NCT05236439 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Suprachoroidal Tube Shunt in Patients With Primary Open and Pseudoexfoliation Glaucomas
NCT06154330 ·Status: RECRUITING
-
Direct Application of Selective Laser Trabeculoplasty in Open Angle Glaucoma
NCT01383525 ·Status: COMPLETED ·Phase: NA