Trial Outcomes & Findings for Panitumumab-IRDye800 and 89Zr-Panitumumab in Identifying Metastatic Lymph Nodes in Patients With Squamous Cell Head and Neck Cancer (NCT NCT03733210)
NCT ID: NCT03733210
Last Updated: 2023-05-19
Results Overview
The ability of 89Zr-panitumumab and 18F-fluorodeoxyglucose (18F-FDG) to detect tumor in lymph nodes were assessed on the basis of radiologic scans and histopathologic evaluation of excised lymph nodes (LNs). The histopathologic assessment was considered the definitive, regular medical care, assessment. The outcome is reported by study group as the number of LNs that were identified as tumor-positive by 18F-FDG- and 89Zr-panitumumab, stratified by the tumor-positivity as assessed by histopathology, and expressed as the number of LNs that were tumor-positive by both, negative for both, or positive for one and not the other. Results are also provided by study group for the number of LNs that tumor-positive by both 18F-FDG- and 89Zr-panitumumab, negative for both, or positive for one and not the other. The outcome is numbers without dispersion
COMPLETED
PHASE1
14 participants
up to 5 days
2023-05-19
Participant Flow
Participant milestones
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence -imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Overall Study
STARTED
|
7
|
7
|
|
Overall Study
COMPLETED
|
3
|
5
|
|
Overall Study
NOT COMPLETED
|
4
|
2
|
Reasons for withdrawal
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence -imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Overall Study
Lymph nodes not collected or not evaluable
|
4
|
2
|
Baseline Characteristics
Panitumumab-IRDye800 and 89Zr-Panitumumab in Identifying Metastatic Lymph Nodes in Patients With Squamous Cell Head and Neck Cancer
Baseline characteristics by cohort
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=7 Participants
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence-imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence-imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=7 Participants
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence-imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence-imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescenc3-imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Total
n=14 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Categorical
<=18 years
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Age, Categorical
Between 18 and 65 years
|
4 Participants
n=99 Participants
|
2 Participants
n=107 Participants
|
6 Participants
n=206 Participants
|
|
Age, Categorical
>=65 years
|
3 Participants
n=99 Participants
|
5 Participants
n=107 Participants
|
8 Participants
n=206 Participants
|
|
Age, Continuous
|
63.8 years
n=99 Participants
|
69.8 years
n=107 Participants
|
68.3 years
n=206 Participants
|
|
Sex: Female, Male
Female
|
3 Participants
n=99 Participants
|
1 Participants
n=107 Participants
|
4 Participants
n=206 Participants
|
|
Sex: Female, Male
Male
|
4 Participants
n=99 Participants
|
6 Participants
n=107 Participants
|
10 Participants
n=206 Participants
|
|
Ethnicity (NIH/OMB)
Hispanic or Latino
|
0 Participants
n=99 Participants
|
1 Participants
n=107 Participants
|
1 Participants
n=206 Participants
|
|
Ethnicity (NIH/OMB)
Not Hispanic or Latino
|
7 Participants
n=99 Participants
|
6 Participants
n=107 Participants
|
13 Participants
n=206 Participants
|
|
Ethnicity (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Race (NIH/OMB)
American Indian or Alaska Native
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Race (NIH/OMB)
Asian
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Race (NIH/OMB)
Black or African American
|
1 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
1 Participants
n=206 Participants
|
|
Race (NIH/OMB)
White
|
6 Participants
n=99 Participants
|
6 Participants
n=107 Participants
|
12 Participants
n=206 Participants
|
|
Race (NIH/OMB)
More than one race
|
0 Participants
n=99 Participants
|
0 Participants
n=107 Participants
|
0 Participants
n=206 Participants
|
|
Race (NIH/OMB)
Unknown or Not Reported
|
0 Participants
n=99 Participants
|
1 Participants
n=107 Participants
|
1 Participants
n=206 Participants
|
|
Region of Enrollment
United States
|
7 participants
n=99 Participants
|
7 participants
n=107 Participants
|
14 participants
n=206 Participants
|
PRIMARY outcome
Timeframe: up to 5 daysPopulation: Some participants did not have lymph nodes collected, or the collected lymph nodes were not evaluable. Some lymph nodes were not evaluable by all methodologies.
The ability of 89Zr-panitumumab and 18F-fluorodeoxyglucose (18F-FDG) to detect tumor in lymph nodes were assessed on the basis of radiologic scans and histopathologic evaluation of excised lymph nodes (LNs). The histopathologic assessment was considered the definitive, regular medical care, assessment. The outcome is reported by study group as the number of LNs that were identified as tumor-positive by 18F-FDG- and 89Zr-panitumumab, stratified by the tumor-positivity as assessed by histopathology, and expressed as the number of LNs that were tumor-positive by both, negative for both, or positive for one and not the other. Results are also provided by study group for the number of LNs that tumor-positive by both 18F-FDG- and 89Zr-panitumumab, negative for both, or positive for one and not the other. The outcome is numbers without dispersion
Outcome measures
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=6 Lymph nodes
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=19 Lymph nodes
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-positive & pathology-positive
|
0 Lymph Nodes
|
4 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-positive & pathology-negative
|
0 Lymph Nodes
|
0 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-negative & pathology-positive
|
0 Lymph Nodes
|
6 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-negative & pathology-negative
|
5 Lymph Nodes
|
6 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
18F-FDG-positive & pathology-positive
|
0 Lymph Nodes
|
7 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
18F-FDG-positive & pathology-negative
|
0 Lymph Nodes
|
3 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
18F-FDG-negative & pathology-positive
|
0 Lymph Nodes
|
2 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
18F-FDG-negative & pathology-negative
|
6 Lymph Nodes
|
6 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-positive & 18F-FDG-positive
|
0 Lymph Nodes
|
2 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-positive & 18F-FDG-negative
|
0 Lymph Nodes
|
1 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-negative & 18F-FDG-positive
|
0 Lymph Nodes
|
8 Lymph Nodes
|
|
Detection of Tumor in Lymph Nodes by 18F-FDG and 89Zr-panitumumab Labeling
89Zr-panitumumab-negative & 18F-FDG-negative
|
5 Lymph Nodes
|
4 Lymph Nodes
|
SECONDARY outcome
Timeframe: up to 5 daysPopulation: Some participants did not have lymph nodes collected, or the collected lymph nodes were not evaluable. Some lymph nodes were not evaluable by all methodologies.Some participants did not have lymph nodes collected, or the collected lymph nodes were not evaluable. Some lymph nodes were not evaluable by all methodologies.
The value of 89Zr-panitumumab and panitumumab-IRDye800 as a label for cancer cells (radiologic or fluorescent, respectively), was assessed by the sensitivity and specificity for the detection of tumor cells in lymph nodes near the tumor. 18F-fluorodeoxyglucose (18F-FDG), an established agent for this use, was also assessed. Sensitivity was assessed as the "true positive rate" of paired measurements, expressed as the proportion (ratio) of the number of specimens positive by histopathology also positive by the test method (test:histopathology). Specificity is the "true negative rate", the proportion of the number of specimens negative by histopathology also negative by the test method. The closer the proportions are to 1, the greater the sensitivity or specificity. The outcome is reported as the sensitivity and specificity of 89Zr-panitumumab, panitumumab-IRDye800, and 18F-fluorodeoxyglucose (18F-FDG). The outcome results are ratios, a number without dispersion.
Outcome measures
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=6 Lymph nodes
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=19 Lymph nodes
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
89Zr-panitumumab Sensitivity
|
0 Ratio
|
0.4 Ratio
|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
89Zr-panitumumab Specificity
|
0 Ratio
|
1.0 Ratio
|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
Panitumumab-IRDye800 Sensitivity
|
0 Ratio
|
1.0 Ratio
|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
Panitumumab-IRDye800 Specificity Panitumumab-IRDye800 Specificity
|
0 Ratio
|
1.0 Ratio
|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
18F-FDG Sensitivity
|
0 Ratio
|
0.78 Ratio
|
|
Sensitivity and Specificity of 89Zr-panitumumab, 18F-FDG, and Panitumumab-IRDye800
18F-FDG Specificity
|
0 Ratio
|
0.67 Ratio
|
OTHER_PRE_SPECIFIED outcome
Timeframe: up to 5 daysPopulation: Some participants did not have lymph nodes collected, or the collected lymph nodes were not evaluable. Some lymph nodes were not evaluable by all methodologies.
The value of experimental 89Zr-panitumumab as a radiologic label was assessed as the number of lymph nodes (LNs) that have false-negative results. A false-negative result in this study is one that does not indicate that cancer is present in the lymph node, when histopathologic evaluation confirms the presence of cancer in the lymph nodes. The outcome is reported as the number of false-negative lymph nodes observed after systemic labeling with 89Zr-panitumumab and 18F-FDG, an established agent for this use. The outcome results are numbers without dispersion.
Outcome measures
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=6 Lymph nodes
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=19 Lymph nodes
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
89Zr-panitumumab and 18F-FDG False-negatives
18F-FDG False-negatives
|
0 Lymph nodes
|
2 Lymph nodes
|
|
89Zr-panitumumab and 18F-FDG False-negatives
89Zr-panitumumab False-negatives
|
0 Lymph nodes
|
6 Lymph nodes
|
OTHER_PRE_SPECIFIED outcome
Timeframe: up to 5 daysPopulation: Some participants did not have lymph nodes collected, or the collected lymph nodes were not evaluable. Some lymph nodes were not evaluable by all methodologies.
The value of experimental 89Zr-panitumumab as a radiologic label was assessed by determining the positive predictive value (PPV) and the negative predictive value (NPV). PPV is a measure of extent that positive-labeled samples that were actually cancer, expressed as a proportion (ratio) of the number of positive-labeled samples vs samples positive by histopathology (positive label/positive histopathology). NPV is a measure of extent that negative-labeled samples (not positive) that were actually NOT cancer, expressed as a proportion (ratio) of the number of negative-labeled samples vs samples NOT positive by histopathology (negative label/negative histopathology). The closer the proportions are to 1, the better the predictive value. The outcome is reported as the PPV and NPV of 89Zr-panitumumab and 18F-fluorodeoxyglucose (18F-FDG), an established agent for this use. The outcome results are ratios, numbers without dispersion.
Outcome measures
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=6 Lymph nodes
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=19 Lymph nodes
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Positive Predictive Value (PPV) and Negative Predictive Value (NPV) of 89Zr-panitumumab and 18F-FDG
89Zr-panitumumab Positive Predictive Value (PPV)
|
0 ratio
|
0.4 ratio
|
|
Positive Predictive Value (PPV) and Negative Predictive Value (NPV) of 89Zr-panitumumab and 18F-FDG
89Zr-panitumumab Negative Predictive Value (NPV)
|
0 ratio
|
1.0 ratio
|
|
Positive Predictive Value (PPV) and Negative Predictive Value (NPV) of 89Zr-panitumumab and 18F-FDG
18F-FDG Positive Predictive Value (PPV)
|
0 ratio
|
0.78 ratio
|
|
Positive Predictive Value (PPV) and Negative Predictive Value (NPV) of 89Zr-panitumumab and 18F-FDG
18F-FDG Negative Predictive Value (NPV)
|
0 ratio
|
0.67 ratio
|
Adverse Events
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
Serious adverse events
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=7 participants at risk
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=7 participants at risk
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Infections and infestations
Sepsis
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
Other adverse events
| Measure |
Tumor-negative Lymph Nodes (by 18F-FDG Scan)
n=7 participants at risk
Participants whose lymph nodes are negative for cancer
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
Tumor-positive Lymph Nodes (by 18F-FDG Scan)
n=7 participants at risk
Participants whose lymph nodes are positive for cancer.
Panitumumab-IRDye800: 30 mg administered intravenously (IV)
Zirconium Zr-89 Panitumumab: 0.8 to 1.2 mCi (29 to 45 Mbq) administered intravenously (IV)
Pinpoint IR IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
SPY-PHI IR9000 fluorescence imaging system (FIS): Handheld fluorescence-imaging endoscope manufactured by Novadaq
Explorer Air camera: Fluorescence camera manufactured by SurgVision
PDE-NEO II camera: Medical infrared camera manufactured by Hamamatsu Photonics KK
FIS-00 fluorescence imaging system (FIS): Fluorescence imaging system (FIS) manufactured by Hamamatsu Photonics KK
Da Vinci Firefly Imaging System: Fluorescence-imaging endoscope, mounted or stand-alone, manufactured by Intuitive Surgical Inc
IGP-ELVIS-v4 Macroscopic Specimen Imager: Macroscopic specimen imager manufactured by LI-COR Biosciences
Vevo 3100 LAZR-X: Photoacoustic ultrasound imaging system manufactured by VisualSonics
Pearl Triology Imaging System: Near-infrared fluorescent and bioluminescent imaging system manufactured by LI-COR Biosciences
Odyssey CLx Imaging System: Infrared fluorescent imaging system manufactured by LI-COR Biosciences
Leica fluorescence microscope: Fluorescence microscope manufactured by Leica
|
|---|---|---|
|
Blood and lymphatic system disorders
Anemia
|
14.3%
1/7 • Number of events 1 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Cardiac disorders
Atrial flutter
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Cardiac disorders
Mobitz (type) II atrioventricular block
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Cardiac disorders
Other
|
14.3%
1/7 • Number of events 1 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Cardiac disorders
Sinus bradycardia
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Endocrine disorders
Hypothyroidism
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Gastrointestinal disorders
Constipation
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
General disorders
Edema face
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
General disorders
Fatigue
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
General disorders
Non-cardiac chest pain
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Infections and infestations
Abdominal infection
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Infections and infestations
Wound infection
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Injury, poisoning and procedural complications
Wound complication
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Investigations
Electrocardiogram QT corrected interval prolonged
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Investigations
Other, hypercarbia
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Metabolism and nutrition disorders
Anorexia
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Metabolism and nutrition disorders
Hypokalemia
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Metabolism and nutrition disorders
Other, refeeding syndrome, mild
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Musculoskeletal and connective tissue disorders
Back pain
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Musculoskeletal and connective tissue disorders
Neck pain
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Nervous system disorders
Aphonia
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Nervous system disorders
Dizziness
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Nervous system disorders
Facial muscle weakness
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Nervous system disorders
Facial nerve disorder
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Nervous system disorders
Headache
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Nervous system disorders
Hypoglossal nerve disorder
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Nervous system disorders
Somnolence
|
28.6%
2/7 • Number of events 3 • 30 days
|
0.00%
0/7 • 30 days
|
|
Renal and urinary disorders
Hematuria
|
28.6%
2/7 • Number of events 2 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Aspiration
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Cough
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Dyspnea
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Hypoxia
|
28.6%
2/7 • Number of events 2 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Other, fistula, nasal-oral, right
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Pleural effusion
|
28.6%
2/7 • Number of events 2 • 30 days
|
0.00%
0/7 • 30 days
|
|
Respiratory, thoracic and mediastinal disorders
Pulmonary edema
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Skin and subcutaneous tissue disorders
Alopecia
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Surgical and medical procedures
Other, - Jackson-Pratt drain with serous drainage and tracheostomy site with mucinous secretion
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Surgical and medical procedures
Other, extravasation along anterior abdominal wall consistent with gastrostomy tube leak
|
14.3%
1/7 • Number of events 1 • 30 days
|
0.00%
0/7 • 30 days
|
|
Surgical and medical procedures
Other, jejunostomy tube leak
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Vascular disorders
Flushing
|
0.00%
0/7 • 30 days
|
14.3%
1/7 • Number of events 1 • 30 days
|
|
Vascular disorders
Hypertension
|
28.6%
2/7 • Number of events 2 • 30 days
|
57.1%
4/7 • Number of events 5 • 30 days
|
|
Vascular disorders
Hypotension
|
42.9%
3/7 • Number of events 3 • 30 days
|
0.00%
0/7 • 30 days
|
Additional Information
Yu-Jin Lee, MD, MS
Stanford Medicine at Stanford University
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place