External Ventricular Drain Placement Stealth Study

NCT03696043 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 31

Last updated 2026-03-16

No results posted yet for this study

Summary

External ventricular drain (EVD) placement is performed very often in neurosurgical practices. EVD's are most commonly placed at the bedside using external anatomical landmarks to guide the catheter into the frontal horn of the ipsilateral lateral ventricle. EVDs are often placed due to acute neurological compromise and require timely insertion.

Accurate catheter placement is essential to achieving effective external CSF drainage without complications or occlusion/failure of the catheter. Catheter placement is most commonly performed via a freehand approach using external anatomical landmarks to help identify the location of the lateral ventricle within the brain without the aid of imaging. Proper identification of the ventricles on pre-procedure imaging, surgeon skill, and estimation of pathologic perturbations to the normal location of the ventricles all factor into the success of catheter placement. Multiple passes are often required. The accuracy rate from the freehand technique has been reported to range from 40 to 98 percent.

Current methods for EVD placement do not compensate for superficial brain vessels or pathology that may alter the intracranial anatomy such as trauma, hemorrhage, or mass lesions. Some studies have attempted to use CTA imaging to identify intracranial vessels in an attempt to avoid them during placement.

Image guidance is a tool used very commonly for placement of EVD's and shunts in the operating room. AxiEM Stealth is a noninvasive image localization modality that registers a CT or MRI to the individual patients facial and scalp anatomy.

This study will compare the current standard of care of freehand placement of bedside external ventricular catheters to the placement of EVD catheters with AxiEM Stealth image guidance.

Conditions

  • External Ventricular Drain
  • Intracranial Pressure

Interventions

OTHER

Axium Steatlh Image Guidance

The Axiem Stealth imaging guidance system uses a probe (AxiEM Registration Probe) and a side mount emitter (AxiEM Side Mount Emitter) to register the patient's head in relation to the probe. A trajectory (entry point and target) is then planned. This registration process takes an estimated 5-15 minutes to perform. A separate stylet (StealthStation EM Stylet) is designed specifically for the catheter and slides down the center of the catheter. A burr-hole is created at the predefined precise location and the catheter is passed to the target under electromagnetic guidance.

OTHER

EVD placement

A sterile field is prepared about 10-12 centimeters posterior to the eye and about 2-3 cm lateral to the midline of the skull. An incision is made at this point and a burr hole is created using a hand drill. The catheter is advanced in a trajectory perpendicular to the skull, which results in a direction that is towards the ipsilateral medial canthus and ipsilateral tragus which are other landmarks that can be used.

Sponsors & Collaborators

  • University of Wisconsin, Madison

    lead OTHER

Principal Investigators

  • Azam Ahmed, MD · University of Wisconsin, Madison

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
88 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-08-15
Primary Completion
2026-03-12
Completion
2026-03-12

Countries

  • United States

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03696043 on ClinicalTrials.gov