Sensing Contact Lens-based Device for 24-hour Monitoring of Intraocular Pressure
NCT03689088 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 9
Last updated 2018-12-04
Summary
Glaucoma is characterized by irreversible vision loss through the progressive death of optic nerve fibers unless timely diagnosis and adequate treatment are provided. Medical therapy is aimed at lowering intraocular pressure (IOP) below a clinically determined target level in order to prevent or slow glaucoma progression. IOP is known to vary with the time of day as well as with daily activities.
The current way of assessing nycthemeral IOP fluctuation is to perform repeated discrete tonometry measurements, allowing only snapshot and non-continuous measurements once per hour in the best cases. The procedure is cumbersome, expensive, inconvenient (disturbed sleep cycle as patient is awoken for nocturnal/sleep period measurements) and may not detect crucial IOP values in time.
Sensimed AG has developed a new contact lens (CL)-based device intended to continuously measure IOP over 24 hours. The objective of this study is to investigate the use of device for 24-hour IOP monitoring in healthy subjects and glaucoma patients.
Conditions
- Glaucoma, Open-Angle
- Healthy
Interventions
- DEVICE
-
Goldfish
Goldfish will be placed in the eye for 24h monitoring
- DEVICE
-
Tonometry
Fellow eye will be measured by tonometry
Sponsors & Collaborators
-
Sensimed AG
lead INDUSTRY
Principal Investigators
-
Robert Wasilewicz, MD · [W]-Eye Clinic
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DEVICE_FEASIBILITY
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2018-05-22
- Primary Completion
- 2018-07-04
- Completion
- 2018-09-06
Countries
- Poland
Study Locations
More Related Trials
-
Smart Soft Contact Lenses for Monitoring Glaucoma
NCT07224542 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Changes in Eye Pressure in Glaucoma Patients Treated with Istent Inject W, Monitored by a Contact Lens Sensor
NCT06607705 ·Status: RECRUITING ·Phase: NA
-
Relationship Between 24-hour IOP Pattern and the 24-hour Blood Pressure Pattern in Patients With POAG
NCT01769521 ·Status: COMPLETED ·Phase: NA
-
Intraocular Pressure (IOP) Patterns in Fast Versus Slow Visual Field (VF) Progression Patients
NCT01828255 ·Status: TERMINATED ·Phase: NA
-
SENSIMED Triggerfish in Closed Eyes
NCT01938287 ·Status: COMPLETED ·Phase: PHASE4
-
IOP Fluctuations in Patients With Primary Open-angle Glaucoma, Before and After Selective Laser Trabeculoplasty
NCT01767753 ·Status: COMPLETED ·Phase: NA
-
IOP Pattern in Primary Angle Closure and Primary Angle Closure Glaucoma Patients, Before and After LPI
NCT01906151 ·Status: WITHDRAWN ·Phase: NA
-
Early Feasibility Study of the Brown Glaucoma Implant in Patients With Severe Visual Impairment or No Light Perceived
NCT03469297 ·Status: COMPLETED ·Phase: NA
-
Pilot Study on Ambulatory Intraocular Pressure and Blood Pressure Monitoring in Glaucoma
NCT01912599 ·Status: COMPLETED ·Phase: NA
-
IOP Fluctuations in Primary Open Angle Glaucoma Patients Before and After Deep Sclerectomy With Collagen Implant
NCT01561001 ·Status: TERMINATED ·Phase: NA
-
Central Corneal Thickness With SENSIMED Triggerfish
NCT01210963 ·Status: COMPLETED
-
IOP Fluctuations in Patients With Sleep Apnea With or Without Primary Open Angle Glaucoma Using Positive Airway Pressure
NCT01560975 ·Status: COMPLETED ·Phase: NA
-
SENSIMED Triggerfish Discomfort During IOP Monitoring
NCT00966108 ·Status: COMPLETED
-
24-hr Intraocular Pressure (IOP) Patterns of Glaucoma Patients After Selective Laser Trabeculoplasty (SLT)
NCT01495312 ·Status: WITHDRAWN ·Phase: NA
-
Safety and Effectiveness of the Sight Sciences VISCO™360 Versus SLT in Primary Open Angle Glaucoma
NCT02928289 ·Status: TERMINATED ·Phase: NA
-
24-hour IOP Fluctuation Profile Recorded With SENSIMED Triggerfish in Primary Open-angle Glaucoma (POAG) Patients After Cataract Surgery
NCT01495299 ·Status: WITHDRAWN
-
Measurement of Ocular Tensional Fluctuation by Triggerfish Lens Before and After Cataract Surgery in Patients With Exfoliative Glaucoma
NCT02658071 ·Status: UNKNOWN
-
Comparison of Sensimed Triggerfish With Goldmann Applanation Tonometry and Perkins Tonometry
NCT01391078 ·Status: COMPLETED ·Phase: NA
-
Continuous Intraocular Pressure (IOP) Monitoring in Pigmentary Dispersion Syndrome and Pigmentary Glaucoma Patients
NCT01253109 ·Status: TERMINATED
-
OMNI 3.1 Surgical System in Subjects With Primary Open-Angle Glaucoma
NCT06991270 ·Status: RECRUITING ·Phase: NA
-
An Open Label Study Assessing the 24-hour Intraocular Pressure Pattern in PAC and PACG Patients, Before and After Laser Peripheral Iridotomy
NCT01906138 ·Status: COMPLETED ·Phase: NA
-
Evaluate the Efficacy and Safety of Glaucoma Implant in Primary Open Angle Glaucoma
NCT05892185 ·Status: UNKNOWN ·Phase: NA
-
Direct Application of Selective Laser Trabeculoplasty in Open Angle Glaucoma
NCT01383525 ·Status: COMPLETED ·Phase: NA
-
A Prospective, Multicenter Study of the OMNI® Surgical System in Pseudophakic Eyes With Open Angle Glaucoma
NCT04465630 ·Status: TERMINATED ·Phase: NA
-
Is the Reduction in IOP After Treatment of 180 Degrees Equivalent to Treatment of 360 Degrees With SLT?
NCT03529591 ·Status: COMPLETED ·Phase: NA