Trial Outcomes & Findings for Inorganic Nitrate Supplementation on Cerebrovascular Aging and Arterial Stiffness Study (NCT NCT03617302)

NCT ID: NCT03617302

Last Updated: 2026-03-04

Results Overview

Common carotid artery compliance measured by ultrasonography and applanation tonometry. Carotid compliance is the change in carotid diameter per change in carotid pulse pressure.

Recruitment status

COMPLETED

Study phase

EARLY_PHASE1

Target enrollment

16 participants

Primary outcome timeframe

Baseline and 2 hours following nitrate-depleted placebo beetroot juice or nitrate-containing beetroot juice

Results posted on

2026-03-04

Participant Flow

Participants were randomly assigned to receive beetroot juice or placebo on visit one and then crossed-over to receive the other treatment on visit 2.

Participant milestones

Participant milestones
Measure
Beetroot Juice First, Then Placebo Beetroot Juice
10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water or placebo
Placebo Beetroot Juice, Then Beetroot Juice
Placebo or 10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water
First Intervention 2 Hrs, Washout 3 Hrs
STARTED
8
8
First Intervention 2 Hrs, Washout 3 Hrs
COMPLETED
8
8
First Intervention 2 Hrs, Washout 3 Hrs
NOT COMPLETED
0
0
2nd Intervention 2 Hrs, Washout 3 Hrs
STARTED
8
8
2nd Intervention 2 Hrs, Washout 3 Hrs
COMPLETED
8
8
2nd Intervention 2 Hrs, Washout 3 Hrs
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Inorganic Nitrate Supplementation on Cerebrovascular Aging and Arterial Stiffness Study

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
All Study Participants
n=16 Participants
10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water. Experimental: Nitrate-containing: Experimental 10 grams of nitrate-depleted beetroot concentrate balanced for anti-oxidant content diluted in 120-180 milliliters of water. Placebo: Nitrate-depleted: Placebo
Age, Categorical
<=18 years
0 Participants
n=41 Participants
Age, Categorical
Between 18 and 65 years
11 Participants
n=41 Participants
Age, Categorical
>=65 years
5 Participants
n=41 Participants
Age, Continuous
63 years
STANDARD_DEVIATION 6.9 • n=41 Participants
Sex: Female, Male
Female
9 Participants
n=41 Participants
Sex: Female, Male
Male
7 Participants
n=41 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
n=41 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
16 Participants
n=41 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
n=41 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
n=41 Participants
Race (NIH/OMB)
Asian
0 Participants
n=41 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
n=41 Participants
Race (NIH/OMB)
Black or African American
0 Participants
n=41 Participants
Race (NIH/OMB)
White
16 Participants
n=41 Participants
Race (NIH/OMB)
More than one race
0 Participants
n=41 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
n=41 Participants

PRIMARY outcome

Timeframe: Baseline and 2 hours following nitrate-depleted placebo beetroot juice or nitrate-containing beetroot juice

Common carotid artery compliance measured by ultrasonography and applanation tonometry. Carotid compliance is the change in carotid diameter per change in carotid pulse pressure.

Outcome measures

Outcome measures
Measure
Beetroot Juice
n=16 Participants
10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water. Experimental: Nitrate-containing: Experimental
Placebo Beetroot Juice
n=16 Participants
10 grams of nitrate-depleted beetroot concentrate balanced for anti-oxidant content diluted in 120-180 milliliters of water. Placebo: Nitrate-depleted: Placebo
Change in Carotid Artery Compliance in mm/mmHg x 10-1
Baseline
0.88 mm/mmHg x 10-1
Standard Error 0.01
0.87 mm/mmHg x 10-1
Standard Error 0.01
Change in Carotid Artery Compliance in mm/mmHg x 10-1
Post 2 hours
0.90 mm/mmHg x 10-1
Standard Error 0.01
0.79 mm/mmHg x 10-1
Standard Error 0.01

PRIMARY outcome

Timeframe: Baseline and 2 hours following nitrate-depleted beetroot juice or nitrate-containing beetroot juice

Carotid Augmentation Index is calculated as the augmentation pressure divided by the pulse pressure, and expressed as a percentage. Higher augmentation index percentage is a worse outcome than lower percentage.

Outcome measures

Outcome measures
Measure
Beetroot Juice
n=16 Participants
10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water. Experimental: Nitrate-containing: Experimental
Placebo Beetroot Juice
n=16 Participants
10 grams of nitrate-depleted beetroot concentrate balanced for anti-oxidant content diluted in 120-180 milliliters of water. Placebo: Nitrate-depleted: Placebo
Change in Carotid Augmentation Index
Baseline
11 % of aug blood pressure to pulse pressur
Standard Error 2
10 % of aug blood pressure to pulse pressur
Standard Error 5
Change in Carotid Augmentation Index
Post 2 hours
19 % of aug blood pressure to pulse pressur
Standard Error 3
17 % of aug blood pressure to pulse pressur
Standard Error 3

PRIMARY outcome

Timeframe: Baseline and 2 hours following nitrate-depleted beetroot juice or nitrate-containing beetroot juice

Carotid pulse pressure measured by carotid tonometry calibrated to brachial mean and diastolic pressure. Carotid pulse pressure is the difference between carotid systolic blood pressure and diastolic blood pressure.

Outcome measures

Outcome measures
Measure
Beetroot Juice
n=16 Participants
10-grams of nitrate-containing beetroot concentrate diluted in 120-180 milliliters of water. Experimental: Nitrate-containing: Experimental
Placebo Beetroot Juice
n=16 Participants
10 grams of nitrate-depleted beetroot concentrate balanced for anti-oxidant content diluted in 120-180 milliliters of water. Placebo: Nitrate-depleted: Placebo
Change in Carotid Pulse Pressure in mmHg
Baseline
45 mmHg
Standard Error 3
44 mmHg
Standard Error 3
Change in Carotid Pulse Pressure in mmHg
Post 2 hours
48 mmHg
Standard Error 3
51 mmHg
Standard Error 3

Adverse Events

Placebo

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Beetroot Juice

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. Gary Pierce

University of Iowa

Phone: 319-335-9487

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place