Trial Outcomes & Findings for The Impact of High-Flow Nasal Cannula on Swallow Function (NCT NCT03590457)

NCT ID: NCT03590457

Last Updated: 2022-09-27

Results Overview

Number of swallows

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

18 participants

Primary outcome timeframe

each swallow frequency exam took 1 minute, exams were done for each flow rate which took up to 2 hours to complete

Results posted on

2022-09-27

Participant Flow

Participant milestones

Participant milestones
Measure
High-Flow/Swallow
All participants will be subjected to all three flows randomly. All participants will be asked swallow water and applesauce Airvo 2; High-Flow nasal cannula system: Noninvasive device used to deliver humidified oxygen at high flow rates up to 60 liters per minute
Overall Study
STARTED
18
Overall Study
COMPLETED
18
Overall Study
NOT COMPLETED
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
High-Flow/Swallow
n=18 Participants
All participants will be subjected to all three flows randomly. All participants will be asked swallow water and applesauce Airvo 2; High-Flow nasal cannula system: Noninvasive device used to deliver humidified oxygen at high flow rates up to 60 liters per minute
Age, Categorical
<=18 years
0 Participants
n=18 Participants
Age, Categorical
Between 18 and 65 years
16 Participants
n=18 Participants
Age, Categorical
>=65 years
2 Participants
n=18 Participants
Region of Enrollment
United States
18 participants
n=18 Participants

PRIMARY outcome

Timeframe: each swallow frequency exam took 1 minute, exams were done for each flow rate which took up to 2 hours to complete

Population: swallow frequency

Number of swallows

Outcome measures

Outcome measures
Measure
High-Flow/Swallow
n=18 Participants
All participants will be subjected to all three flows randomly. All participants will be asked swallow water and applesauce Airvo 2; High-Flow nasal cannula system: Noninvasive device used to deliver humidified oxygen at high flow rates up to 60 liters per minute
Swallow Frequency Recorded by Surface Electromyography (sEMG)
swallow frequency at baseline
1.12 number of swallows
Standard Deviation 0.75
Swallow Frequency Recorded by Surface Electromyography (sEMG)
swallow frequency at 30 L/min
1.13 number of swallows
Standard Deviation 0.79
Swallow Frequency Recorded by Surface Electromyography (sEMG)
swallow frequency at 45 L/min
3.91 number of swallows
Standard Deviation 10.26
Swallow Frequency Recorded by Surface Electromyography (sEMG)
swallow frequency at 60 L/min
1.01 number of swallows
Standard Deviation 0.67

Adverse Events

High-Flow/Swallow

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Dr. Brady Scott

Rush University

Phone: 3129426389

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place