Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Jaundice
NCT03569254 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 64
Last updated 2018-07-19
Summary
Objective: to evaluate the effectiveness, safety and level of satisfaction of parents and healthcare team with one innovative device for phototherapy to which a LED light mesh has been incorporated(a blanket), comparing it with the Ohmeda BiliBlanket Plus®. Methods: randomized controlled clinical trial with preterm or low birth weight infants requiring phototherapy. The study protocol was evaluated and accepted by the San Ignacio Hospital and "Pontificia Universidad Javeriana" research committee. Informed consent was requested from parents and the authors declared no conflict of interest. Sample size and allocation: using the STATA 12 program, a sample size of 64 patients was calculated(5% losses), 32 for each group, with significance level of 0.05, power of 80% and difference in bilirubin decreasing of at least 0,1 mg/dl/h with standard deviation of 0.14 mg/dl/h. A computer program randomized the allocation to the intervention and the concealment of the assignment was through sealed opaque envelopes. Seric bilirubin levels were taken at the start and at the end of phototherapy. Controls were done every 2 hours with the Bilicheck spectrophotometer device. Axillary temperature was measured at the beginning of phototherapy, at 30 min, 60 min, and every 2 hours during intervention. Physical examination and recording of side effects related were performed. Parents and health personnel answered a survey on comfort and perceptions with the use of the devices at the end of phototherapy. Analysis: Comparison of means was made for the decrease of bilirubin levels and body temperatures and chi-square for incidence of side effects and results of the survey.
Conditions
- Jaundice, Neonatal
- Phototherapy
Interventions
- DEVICE
-
Neomedlight Phototherapy Blanket
The NeoMedLight® phototherapy blanket is an innovative new fiber-optic device based on LED light. Its light emitting surface area is 40.5x30 cm or 1200 cm2. The device size is 40.5 x30 cm. It incorporates fiber optic mesh and is protected by a vinyl cover and a disposable liner for patient comfort and hygiene. This device provides therapeutic light (404-515nm) to a wide extension of the body surface area. Its average irradiation footprint is 35uW / cm2 / nm ± 15%. The phototherapy was done intermittently in periods of 2 hours with 1 hour of rest for a total time of 6 hours in kangaroo position.
- DEVICE
-
Ohmeda-Fiber Optic Phototherapy Blanket
This device is a high performance version of Ohmeda Medical's Biliblanket that uses a fiber optic cable to deliver light from a high-intensity lamp to a device composed of a fiber optic fabric. The device has a disposable liner and is left in direct contact with the patient. The patient is exposed to a light with a wavelength between 400 and 550 nanometers. The phototherapy system consists of a light emitting unit, a fiber optic cable four feet long (121.9 cm) and a lightweight mattress. It has two available sizes: 4.38 x 9.38 inches (11.12 x 23.83 cm) and 4.00 x 6.00 inches (10.16 x 15.2 cm).
Sponsors & Collaborators
-
Hospital Universitario San Ignacio
collaborator OTHER -
Nathalie Charpak
lead OTHER
Principal Investigators
-
Nathalie Charpak, Dr. · Kangaroo Foundation Director
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Max Age
- 1 Month
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2016-03-01
- Primary Completion
- 2017-10-05
- Completion
- 2017-10-05
Countries
- Colombia
Study Locations
More Related Trials
-
Comparison Between Effect of Conventional, Intensive and Light Emitting Diodes (LED) Phototherapy on Oxidative Stress Among Neonates With Unconjugated Hyperbilirubinemia
NCT03074292 ·Status: UNKNOWN ·Phase: NA
-
Treatment of Neonatal Jaundice With Filtered Sunlight Phototherapy: Safety and Efficacy in African Neonates
NCT01434810 ·Status: COMPLETED ·Phase: NA
-
Newborn Jaundice - An Investigation of Different Approaches to Light Therapy
NCT06702241 ·Status: RECRUITING ·Phase: PHASE2/PHASE3
-
Reliability of Transcutaneous Bilirubin Measurement According to the Skin Colour of Newborns
NCT07315126 ·Status: NOT_YET_RECRUITING
-
Cycled Phototherapy: A Safer Effective Treatment for Small Premature Infants?
NCT01944696 ·Status: UNKNOWN ·Phase: NA
-
Polyethylene Body Bags as an Alternative to Radiant Heat Lamp During the Neonatal Adaptation in Infants Older Than 29 Weeks
NCT02250079 ·Status: COMPLETED ·Phase: PHASE3
-
Testing A Visual Thermometer in Newborns and Young Infants
NCT05609292 ·Status: COMPLETED
-
A Light Emitting Diode (LED) Mattress for Phototherapy of Jaundiced Newborns
NCT03723005 ·Status: COMPLETED
-
Effect of Repositioning Frequency Neonates Receiving Phototherapy
NCT05692648 ·Status: COMPLETED ·Phase: NA
-
Transcutaneous Bilirubinometry and Phototherapy
NCT04246229 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Efficacy Study of the Draeger Jaundice Meter (JM-105) in Neonates of ≥ 24 Weeks of Gestational Age
NCT02774434 ·Status: COMPLETED ·Phase: NA
-
The Effect of Total Body Massage on Neonatal Jaundice in Preterm Neonates
NCT07106164 ·Status: COMPLETED ·Phase: NA
-
Cycled Phototherapy
NCT03927833 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Efficacy of A Novel in Prevention of Neonatal Hypothermia
NCT05729698 ·Status: COMPLETED ·Phase: NA
-
The Effect of Phototherapy Treatment on Oxygen Saturation Measurement in Newborns
NCT04494217 ·Status: COMPLETED
-
Heat Loss Prevention in Very Preterm Infants in Delivery Rooms: A Multicenter, Randomized, Controlled Trial of Polyethylene Occlusive Total Body Skin Wrapping
NCT01671241 ·Status: UNKNOWN ·Phase: PHASE3
-
Value of Transcutaneous Bilirubin Devices
NCT06232174 ·Status: NOT_YET_RECRUITING
-
Wireless Irradiance SEnsors During Neonatal Phototherapy
NCT07057635 ·Status: ACTIVE_NOT_RECRUITING
-
Trial of Aggressive Versus Conservative Phototherapy in Infants <1,000 Grams Birth Weight
NCT00114543 ·Status: COMPLETED ·Phase: PHASE3
-
Implementation of a Transcutaneous Bilirubinometer
NCT01622699 ·Status: COMPLETED ·Phase: NA
-
Transcutaneous Bilirubinometry in Healthy Term and Near-Term Neonates
NCT00653874 ·Status: COMPLETED ·Phase: PHASE3
-
Effectiveness of Music Therapy on the Development of Preterm Neonates
NCT02948491 ·Status: UNKNOWN ·Phase: NA
-
Intelligent Follow-up of Neonatal Jaundice Based on Early Indicators and Internet Communications
NCT05365984 ·Status: UNKNOWN ·Phase: NA
-
mHealth to Screen for Neonatal Jaundice in Low-resource Mexican Settings: a Feasibility Study
NCT06073444 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Smartphone-based Screening Tool (Picterus JP) for Neonatal Jaundice (Chicago)
NCT05521607 ·Status: RECRUITING ·Phase: NA